1 Scope*
1.1 This specification
2 covers nominal wall and minimum wall seamless ferritic alloy-steel pipe intended for hightemperature service. Pipe ordered to this specification shall be suitable for bending, flanging (vanstoning), and similar forming operations, and for fusion welding. Selection will depend upon design, service conditions, mechanical properties, and high-temperature characteristics.
1.2 Several grades of ferritic steels (see Note 1) are covered. Their compositions are given in Table 1.
NOTE 1—Ferritic steels in this specification are defined as low- and intermediate-alloy steels containing up to and including 10 % chromium.
1.3 Supplementary requirements (S1 to S7) of an optional nature are provided. These supplementary requirements call for additional tests to be made, and when desired, shall be so statedb in the order together with the number of such tests required.www we
1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. The inch-pound units shall apply unless the “M” designation of this specification is specified in the order.
NOTE 2—The dimensionless designator NPS (nominal pipe size) has been substituted in this standard for such traditional terms as “nominal diameter,” “size,” and “nominal size.”
2 Referenced Documents
2.1 ASTM Standards:
3
A999/A999M Specification for General Requirements for Alloy and Stainless Steel Pipe
E92 Test Method for Vickers Hardness of Metallic Materials
4
E213 Practice for Ultrasonic Testing of Metal Pipe and Tubing
E309 Practice for Eddy-Current Examination of Steel Tubular Products Using Magnetic Saturation
E381 Method of Macroetch Testing Steel Bars, Billets, Blooms, and Forgings
E527 Practice for Numbering Metals and Alloys in the Unified Numbering System (UNS)
E570 Practice for Flux Leakage Examination of Ferromagnetic Steel Tubular Products
2.2 ASME Standard:
B36.10M Welded and Seamless Wrought Steel Pipe
2.3 AWS Specifications
5
oos
A5.5/A5.5M Specification for Low-Alloy Steel Electrodes for Shielded Metal Arc Welding
A5.23/A5.23M Specification for Low-Alloy Steel Electrodes and Fluxes for Submerged Arc Welding
A5.28/A5.28M Specification for Low-Alloy Steel Electrodes for Gas Shielded Arc Welding
A5.29/A5.29M Low-Alloy Steel Electrodes for Flux Cored Arc Welding
2.4 Other Documents:
SNT-TC-1A Recommended Practice for Nondestructive Personnel Qualification and Certification
6
SAE J 1086 Practice for Numbering Metals and Alloys (UNS)
7
1 This specification is under the jurisdiction of ASTM Committee A01 on Steel, Stainless Steel and Related Alloys and is the direct responsibility of Subcommittee A01.10 on Stainless and Alloy Steel Tubular Products.
Current edition approved Oct. 1, 2011. Published November 2011. Originally approved in 1951. Last previous edition approved in 2010 as A335/A335M–10b. DOI: 10.1520/A0335_A0335M-11.
2 For ASME Boiler and Pressure Vessel Code applications see related Specification SA-335 in Section II of that Code.
3 For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards volume information, refer to the standard’s Document Summary page on the ASTM website.
4 Withdrawn. The last approved version of this historical standard is referenced on www.astm.org.
5 Available from American Welding Society (AWS), 550 NW LeJeune Rd., Miami, FL 33126, http://www.aws.org.
6 Available from American Society for Nondestructive Testing (ASNT), P.O. Box 28518, 1711 Arlingate Ln., Columbus, OH 43228-0518, http://www.asnt.org.
7 Available from SAE International (SAE), 400 Commonwealth Dr., Warrendale, PA 15096-0001, http://www.sae.org.
| Grade | UNS DesignationA | Composition, % | |||||||
| Carbon | Man-ganese | Phos-phorus, max | Sulfur, max | Silicon | Chromium | Molybdenum | Others | ||
| P1 | K11522 | 0.10–0.20 | 0.30–0.80 | 0.025 | 0.025 | 0.10–0.50 | ... | 0.44–0.65 | ... |
| P2 | K11547 | 0.10–0.20 | 0.30–0.61 | 0.025 | 0.025 | 0.10–0.30 | 0.50–0.81 | 0.44–0.65 | ... |
| P5 | K41545 | 0.15 max | 0.30–0.60 | 0.025 | 0.025 | 0.50 max | 4.00–6.00 | 0.45–0.65 | ... |
| P5b | K51545 | 0.15 max | 0.30–0.60 | 0.025 | 0.025 | 1.00–2.00 | 4.00–6.00 | 0.45–0.65 | ... |
| P5c | K41245 | 0.12 max | 0.30–0.60 | 0.025 | 0.025 | 0.50 max | 4.00–6.00 | 0.45–0.65 | ...B |
| P9 | S50400 | 0.15 max | 0.30–0.60 | 0.025 | 0.025 | 0.25–1.00 | 8.00–10.00 | 0.90–1.10 | ... |
| P11 | K11597 | 0.05–0.15 | 0.30–0.60 | 0.025 | 0.025 | 0.50–1.00 | 1.00–1.50 | 0.44–0.65 | ... |
| P12 | K11562 | 0.05–0.15 | 0.30–0.61 | 0.025 | 0.025 | 0.50 max | 0.80–1.25 | 0.44–0.65 | ... |
| P15 | K11578 | 0.05–0.15 | 0.30–0.60 | 0.025 | 0.025 | 1.15–1.65 | ... | 0.44–0.65 | ... |
| P21 | K31545 | 0.05–0.15 | 0.30–0.60 | 0.025 | 0.025 | 0.50 max | 2.65–3.35 | 0.80–1.06 | ... |
| P22 | K21590 | 0.05–0.15 | 0.30–0.60 | 0.025 | 0.025 | 0.50 max | 1.90–2.60 | 0.87–1.13 | ... |
| P23 | K41650 | 0.04–0.10 | 0.10–0.60 | 0.030 max | 0.010 max | 0.50 max | 1.90–2.60 | 0.05–0.30 | V 0.20–0.30Cb 0.02–0.08B 0.0010–0.006N 0.015 maxAl 0.030 maxW 1.45–1.75Ni 0.40 maxTi 0.005–0.060Ti/N ≥ 3.5CB 0.0015–0.007 |
| P24 | K30736 | 0.05–0.10 | 0.30–0.70 | 0.020 | 0.010 | 0.15–0.45 | 2.20–2.60 | 0.90–1.10 | V 0.20–0.30Ti 0.06–0.10N 0.012 maxAl 0.02 maxB 0.0015–0.007 |
| P36 | K21001 | 0.10–0.17 | 0.80–1.20 | 0.030 max | 0.025 max | 0.25–0.50 | 0.30 max | 0.25–0.50 | Ni 1.00–1.30Cu 0.50–0.80Cb 0.015–0.045V 0.02 maxN 0.02 maxAl 0.050 max |
| P91 | K91560 | 0.08–0.12 | 0.30–0.60 | 0.020 | 0.010 | 0.20–0.50 | 8.00–9.50 | 0.85–1.05 | V 0.18–0.25N 0.030–0.070Ni 0.40 maxAl 0.02 maxCb 0.06–0.10Ti 0.01 maxZr 0.01 max |
| P92 | K92460 | 0.07–0.13 | 0.30–0.60 | 0.020 | 0.010 | 0.50 max | 8.50–9.50 | 0.30–0.60 | V 0.15–0.25N 0.03–0.07Ni 0.40 maxAl 0.02 maxCb 0.04–0.09W 1.5–2.00B 0.001–0.006Ti 0.01 maxZr 0.01 max |
| P122 | K92930 | 0.07–0.14 | 0.70 max | 0.020 | 0.010 | 0.50 max | 10.00–11.50 | 0.25–0.60 | V 0.15–0.30W 1.50–2.50Cu 0.30–1.70Cb 0.04–0.10B 0.0005–0.005N 0.040–0.100Ni 0.50 maxAl 0.020 maxTi 0.01 maxZr 0.01 max |
| P911 | K91061 | 0.09–0.13 | 0.30–0.60 | 0.020 max | 0.010 max | 0.10–0.50 | 8.5–9.5 | 0.90–1.10 | V 0.18–0.25Ni 0.40 maxCb 0.060–0.10B 0.0003–0.006N 0.04–0.09Al 0.02 maxW 0.90–1.10Ti 0.01 maxZr 0.01 max |
B Grade P 5c shall have a titanium content of not less than 4 times the carbon content and not more than 0.70 %; or a columbium content of 8 to 10 times the carbon content.
C
Alternatively, in lieu of this ratio minimum, the material shall have a minimum hardness of 275 HV in the hardened condition, defined as after austenitizing and cooling to room temperature but prior to tempering. Hardness testing shall be performed at mid-thickness of the product. Hardness test frequency shall be two samples of product per heat treatment lot and the hardness testing results shall be reported on the material test report.
3 Ordering Information
3.1 Orders for material under this specification should include the following, as required, to describe the desired material adequately:
3.1.1 Quantity (feet, metres, or number of lengths),
3.1.2 Name of material (seamless alloy steel pipe),
3.1.3 Grade (Table 1),
3.1.4 Manufacture (hot-finished or cold-drawn),
3.1.5 Size using one of the following:
3.1.5.1 NPS and schedule number,
3.1.5.2 Outside diameter and nominal wall thickness,
3.1.5.3 Outside diameter and minimum wall thickness,
3.1.5.4 Inside diameter and nominal wall thickness, and
3.1.5.5 Inside diameter and minimum wall thickness.
3.1.6 Length (specific or random),
3.1.7 End finish (Ends Section of Specification A999/ A999M),
3.1.8 Optional requirements (Section 8, 12 and 13 of this specification. See the Sections on Hydrostatic Test Require-
ments and Permissible Variation in Weight for Seamless Pipe in Specification A999/A999M),
3.1.9 Specification designation, and
3.1.10 Special requirements or any supplementary requirements selected, or both.
4 General Requirements
4.1 Material furnished to this specification shall conform to the applicable requirements of the current edition of Specification A999/A999M, unless otherwise provided herein.
5 Materials and Manufacture
5.1 Pipe may be either hot finished or cold drawn with the finishing treatment as required in 5.3.
5.2 Grade P2 and P12—The steel shall be made by coarsegrain melting practice. Specific limits, if any, on grain size or deoxidation practice shall be a matter of agreement between the manufacturer and purchaser.
5.3 Heat Treatment:
| Grade | Heat Treat Type | Normalizing Temperature, min or range °F [°C] | Cooling Media | Subcritical Annealing or Tempering Temperature, min or range °F [°C] |
| P1 | full or isothermal anneal | ... | ... | ... |
| normalize and temper | ... | ... | 1200 [650] | |
| subcritical anneal | ... | ... | 1200-1300 [650-705] | |
| P2 | full or isothermal anneal | ... | ... | ... |
| normalize and temper | ... | ... | 1250 [675] | |
| subcritical anneal | ... | ... | 1200-1300 [650-705] | |
| P5 | full or isothermal anneal | ... | ... | ... |
| normalize and temper | ... | ... | 1250 [675] | |
| P5b | full or isothermal anneal | ... | ... | ... |
| normalize and temper | ... | ... | 1250 [675] | |
| P5c | subcritical anneal | ... | ... | 1325-1375 [715-745] |
| P9 | full or isothermal anneal | ... | ... | ... |
| normalize and temper | ... | ... | 1250 [675] | |
| P11 | full or isothermal anneal | ... | ... | ... |
| normalize and temper | ... | ... | 1200 [650] | |
| P12 | full or isothermal anneal | ... | ... | ... |
| normalize and temper | ... | ... | 1200 [650] | |
| subcritical anneal | ... | ... | 1200-1300 [650-705] | |
| P15 | full or isothermal anneal | ... | ... | ... |
| normalize and temper | ... | ... | 1200 [650] | |
| P21 | full or isothermal anneal | ... | ... | ... |
| normalize and temper | ... | ... | 1250 [675] | |
| P22 | full or isothermal anneal | ... | ... | ... |
| normalize and temper | ... | ... | 1250 [675] | |
| P23 | normalize and temper | 1900-1975 [1040-1080] | air or accelerated cooling | 1350-1470 [730-800] |
| P24 | normalize and temper | 1800-1870 [980-1020] | air or accelerated cooling | 1350-1420 [730-770] |
| P36 | normalize and temperB | 1650 [900] | ... | 1100 [595] |
| P91 | normalize and temper | 1900-1975 [1040-1080] | ... | 1350-1470 [730-800]C |
| quench and temperD | 1900-1975 [1040-1080] | ... | 1350-1470 [730-800] | |
| P92 | normalize and temper | 1900-1975 [1040-1080] | E | 1350-1470 [730-800] |
| P122 | normalize and temper | 1900-1975 [1040-1080] | ... | 1350-1470 [730-800] |
| P911 | normalize and temper | 1900-1975 [1040-1080] | E | 1365-1435 [740-780] |
5.3.1 All pipe shall be reheated for heat treatment and heat treated in accordance with the requirements of Table 2. NOTE 3—It is recommended that the temperature for tempering should be at least 100 °F [50 °C] above the intended service temperature; consequently, the purchaser should advise the manufacturer if the service temperature is to be over 1100 °F [600 °C].
NOTE 4—Certain of the ferritic steels covered by this specification will harden if cooled rapidly from above their critical temperature. Some will air harden, that is, become hardened to an undesirable degree when cooled in air from high temperatures. Therefore, operations involving heating such steels above their critical temperatures, such as welding, flanging, and hot bending, should be followed by suitable heat treatment.
6 Chemical Composition
6.1 The steel shall conform to the requirements as to chemical composition prescribed in Table 1.
7 Workmanship, Finish, and Appearance
7.1 The pipe manufacturer shall explore a sufficient number of visual surface imperfections to provide reasonable assurance that they have been properly evaluated with respect to depth. Exploration of all surface imperfections is not required but may be necessary to ensure compliance with 7.2
7.2 Surface imperfections that penetrate more than 12
1
⁄2 % of the nominal wall thickness or encroach on the minimum wall thickness shall be considered defects. Pipe with such defects shall be given one of the following dispositions:
7.2.1 The defect may be removed by grinding provided that the remaining wall thickness is within specified limits.
7.2.2 Repaired in accordance with the repair welding pro-ww we visions of 7.6.
7.2.3 The section of pipe containing the defect may be cut off within the limits of requirements on length.
7.2.4 Rejected.
7.3 To provide a workmanlike finish and basis for evaluating conformance with 7.2, the pipe manufacturer shall remove by grinding the following:
7.3.1 Mechanical marks, abrasions (see Note 5) and pits, any of which imperfections are deeper than 1
⁄16 in. [1.6 mm]. NOTE 5—Marks and abrasions are defined as cable marks, dinges, guide marks, roll marks, ball scratches, scores, die marks, and the like.
7.3.2 Visual imperfections, commonly referred to as scabs, seams, laps, tears, or slivers, found by exploration in accordance with 7.1 to be deeper than 5 % of the nominal wall thickness.
7.4 At the purchaser’s discretion, pipe shall be subject to rejection if surface imperfections acceptable under 7.2 are not scattered, but appear over a large area in excess of what is considered a workmanlike finish. Disposition of such pipe shall be a matter of agreement between the manufacturer and the purchaser.
7.5 When imperfections or defects are removed by grinding, a smooth curved surface shall be maintained, and the wall thickness shall not be decreased below that permitted by this specification. The outside diameter at the point of grinding may be reduced by the amount so removed.
7.5.1 Wall thickness measurements shall be made with a mechanical caliper or with a properly calibrated nondestructive testing device of appropriate accuracy. In case of dispute, the measurement determined by use of the mechanical caliper shall govern.
7.6 Weld repair shall be permitted only subject to the approval of the purchaser and in accordance with Specification A999/A999M.
7.6.1 All repair welds in P91 shall be made with one of the following welding processes and consumables: SMAW, A5.5/ A5.5M E90XX-B9; SAW, A5.23/A5.23M EB9 + neutral flux; GTAW, A5.28/A5.28M ER90S-B9; and FCAW A5.29/A5.29M E91T1-B9. In addition, the sum of the Ni+Mn content of all welding consumables used to weld repair P91 shall not exceed 1.0 %.
7.6.2 All repair welds in P92, P911, and P122, shall be made using welding consumables meeting the chemical requirements for the grade in Table 1.
7.6.3 After weld repair, Grades P23, P91, P92, and P122 shall be heat treated at 1350-1470 ºF [730-800 ºC].
7.6.4 After weld repair, Grade P911 shall be heat treated at 1365-1435 ºF [740-780 ºC].
7.6.5 After weld repair, Grade P24 shall be heat treated at 1350-1420 °F [730-770 °C].
7.7 The finished pipe shall be reasonably straight.
8 Product Analysis
8.1 At the request of the purchaser, an analysis of two pipes from each lot as defined hereafter shall be made by the manufacturer. A lot is all pipe of the same nominal size andoos co wall thickness (schedule) which is produced from the same heat of steel and shall be limited as follows:.
| NPS Designator | Maximum Number of Lengths in a Lot |
| Under 2 | 400 |
| 2 to 5 | 200 |
| 6 and over | 100 |
8.2 The results of these analyses shall be reported to the purchaser or the purchaser’s representative, and shall conform to the requirements specified in Table 1.
8.3 For grade P 91 the carbon content may vary for the product analysis by −0.01 % and +0.02 % from the specified range as per Table 1.
8.4 If the analysis of one of the tests specified in 8.1 does not conform to the requirements specified in 6.1, an analysis of each billet or pipe from the same heat or lot may be made, and all billets or pipe conforming to the requirements shall be accepted.
9 Tensile and Hardness Requirements
9.1 The tensile properties of the material shall conform to the requirements prescribed in Table 3.
9.2 Table 4 lists elongation requirements.
9.3 Pipe of Grade P91 shall have a hardness inclusively in the range 190 to 250 HBW/196 to 265 HV [91 HRB to 25 HRC]. Pipe of Grades P24, P92, P122, and P36 shall have a hardness not exceeding 250 HBW/265 HV30 [25 HRC].
9.4 Table 5 gives the computed minimum elongation values for each 1
⁄32-in. [0.8-mm] decrease in wall thickness. Where the
| Grade | |||||||||
| P1, P2 | P12 | P23 | P24 | P91 | P92, P911 P36 Class 1 | P122 | P36 Class 2 | All Others | |
| Tensile strength, | |||||||||
| min: | |||||||||
| ksi | 55 | 60 | 74 | 85 | 85 | 90 | 90 | 95.5 | 60 |
| MPa | 380 | 415 | 510 | 585 | 585 | 620 | 620 | 660 | 415 |
| Yield strength, | |||||||||
| min: | |||||||||
| ksi | 30 | 32 | 58 | 60 | 60 | 64 | 58 | 66.5 | 30 |
| MPa | 205 | 220 | 400 | 415 | 415 | 440 | 400 | 460 | 205 |
| Elongation Requirements | |||||
| All grades except P23, P36 P91, P92, P122, and P911 | P23, P24, P91, P92, P122, and P 911 | P36 | |||
| Longi-tudi-nal | Trans-verse | Longi-tudi-nal | Trans-verse | Longi-tudi-nal | |
| Elongation in 2 in. or 50 mm, (or 4D), min, %: | |||||
| Basic minimum elongation for wall 5/16 in. [8 mm] and over in thickness, strip tests, and for all small sizes tested in full section | 30 | 20 | 20 | ... | 15 |
| When standard round 2-in. or 50-mm gage length or proportionally smaller size specimen with the gage length equal to 4D (4 times the diameter) is used | 22 | 14 | 20 | 13 | ... |
| For strip tests a deduction for each 1/32-in. [0.8 mm] decrease in wall thickness below in. [8 mm] from the basic minimum elongation of the following percentage points shall be made | 1.50A | 1.00A | 1.00A | ... | 1.00A |
wall thickness lies between two values above, the minimum elongation value is determined by the following formula:
| Direction of Test | EquationB |
| Longitudinal, all grades except P23, P91, P92, P122, and P911 | E = 48t + 15.00[E = 1.87t + 15.00] |
| Transverse, all grades except P23, P91, P92, P122, and P911 | E = 32t + 10.00[E = 1.25t + 10.00] |
| Longitudinal, P23, P24, P91, P92, P122, and P911 | E = 32t + 10.00[E = 1.25t + 10.00] |
| Longitudinal, P36 | E = 32t + 5.0[E = 1.25t + 5.0] |
9.5 For Grade P91, when quenching and tempering has been agreed upon in accordance with Note D in Table 2, the tensile
and hardness properties shall be met and verified on material taken from the half-thickness location.
10 Permissible Variations in Diameter
10.1 For pipe ordered to NPS [DN] or outside diameter, variations in outside diameter shall not exceed those specified in Table 6.
10.2 For pipe ordered to inside diameter, the inside diameter shall not vary more than 6 1 % from the specified inside diameter.
11 Permissible Variations in Wall Thickness
11.1 In addition to the implicit limitation of wall thickness for pipe imposed by the limitation on weight in Specification A999/A999M, the wall thickness for pipe at any point shall be within the tolerances specified in Table 7. The minimum wall thickness and outside diameter for inspection for compliance with this requirement for pipe ordered by NPS [DN] andoos.co schedule number is shown in ASME B36.10M.
12 Hydrostatic Test
12.1 The requirements for grades other than P91, P92, P911, and P122 are shown in 12.1.1-12.1.4.
12.1.1 Each length of pipe with outside diameter greater than 10 in. [250 mm] and wall thickness less than or equal to 0.75 in. [19 mm], shall be submitted to the hydrostatic test, except as provided for in 12.1.4.
12.1.2 Pipe of all other sizes shall be subjected to the nondestructive electric test as shown in Section 13, except as provided for in 12.1.3 and 12.1.4.
12.1.3 When specified by the purchaser, pipe of all other sizes shall be furnished without the hydrostatic test and without nondestructive examination.
12.1.4 When specified by the purchaser, pipe shall be furnished with both the hydrostatic test and a nondestructive examination having been performed.
12.2 The requirements for grades P91, P92, P911, and P122 are shown in 12.2.1-12.2.3.
12.2.1 Each length of pipe with outside diameter greater than 10 in. [250 mm] and wall thickness less than or equal to 0.75 in. [19 mm], shall be submitted to both the hydrostatic test and the ultrasonic test as shown in Section 13.
| Wall Thickness | Elongation in 2 in. or 50 mm, min, % | ||||
| All grades except P23, P36, P91, P92, P122, and P911 | P23, P24, P91, P92, P122, and P911 | P36 | |||
| in. | mm | Longi-tudinal | Transverse | Longi-tudinal | Longi-tudinal |
| 5/16 (0.312) | 8 | 30 | 20 | 20 | 15 |
| 9/32 (0.281) | 7.2 | 28 | 19 | 19 | 14 |
| 1/4 (0.250) | 6.4 | 27 | 18 | 18 | 13 |
| 7/32 (0.219) | 5.6 | 26 | ... | 17 | 12 |
| 3/16 (0.188) | 4.8 | 24 | ... | 16 | 11 |
| 5/32 (0.156) | 4 | 22 | ... | 15 | 10 |
| 1/8 (0.125) | 3.2 | 21 | ... | 14 | 9 |
| 3/32 (0.094) | 2.4 | 20 | ... | 13 | 8 |
| 1/16 (0.062) | 1.6 | 18 | ... | 12 | 7 |
| NPS [DN] Designator | Over | Under | ||
| in. | mm | in. | mm | |
| 1/8 to 11/2 [6 to 40], incl. | 1/64 (0.015) | 0.40 | 1/64 (0.015) | 0.40 |
| Over 11/2 to 4 [40 to 100], incl. | 1/32 (0.031) | 0.79 | 1/32 (0.031) | 0.79 |
| Over 4 to 8 [100 to 200], incl. | 1/16 (0.062) | 1.59 | 1/32 (0.031) | 0.79 |
| Over 8 to 12 [200 to 300], incl. | 3/32 (0.093) | 2.38 | 1/32 (0.031) | 0.79 |
| Over 12 [300] | ± 1 % of the specified outside diameter | |||
| NPS [DN] Designator | Tolerance, % | from Specified |
| 1⁄8 to 21⁄2 [6 to 65] incl., all t/D ratiosA | Over20.0 | Under12.5 |
| Above 21⁄2 [65], t/D # 5 %A | 22.5 | 12.5 |
| Above 21⁄2 [65], t/D > 5 %A | 15.0 | 12.5 |
12.2.2 Pipe of all other sizes shall be subjected to the nondestructive electric test as shown in Section 13, except as provided for in 12.2.3.
12.2.3 When specified by the purchaser, pipe of all other sizes shall be furnished with both the hydrostatic test and a nondestructive examination having been performed.
13 Nondestructive Examination
13.1 When required by 12.1.2 or 12.2 above, or when specified in the purchase order in addition to the hydrostatic test (12.2.3), each pipe shall be examined by a nondestructive examination method in accordance with Practice E213, Practice E309, or Practice E570. Except for Grades P91, P92, P911, and P122, the type of nondestructive examination shall be at the option of the manufacturer, unless otherwise specified in the order. Grades P91, P92, P911, and P122 shall be examined by an examination method in accordance with Practice E213. When specified in the order, pipe of Grades P91, P92, P911, and P122 shall be examined by an examination method in accordance with Practices E309 or E570, in addition to the examination method in accordance with Practice E213. The
range of pipe sizes that may be examined by each method shall be subject to the limitations in the scope of the respective practices.
13.2 Following conditions apply in lieu or in addition to those in Specification A999/A999M:
13.2.1 The width of the notch shall not exceed the depth.
13.2.2 If upon any standardization, the reference signal amplitude has decreased by more than 25 % (2 db), the test apparatus shall be considered out of standardization. The test system settings may be changed, or the transducer(s), coil(s) or sensor(s) adjusted, and the unit restandardized, but all pipe tested since the last acceptable standardization shall be retested.
13.2.3 Pipes producing a signal equal to or greater than the signal produced by the reference standard shall be subject tooos co one of the following four dispositions:
13.2.3.1 The pipes may be rejected without further examination, at the discretion of the manufacturer.
13.2.3.3 The pipes may be repaired by grinding (in accordance with 7.2.1), welding (in accordance with 7.6) or sectioning (in accordance with 7.2.3). To be accepted, a repaired pipe must pass the same nondestructive examination by which it was rejected, and it must meet the remaining wall thickness requirements of this specification.
13.2.3.4 If the test signals were produced by visual imperfections such as those listed below, the pipes may be evaluated in accordance with the provisions of Section 7:
(a) Scratches,
(b) Surface roughness,
(c) Dings,
(d) Straightener marks,
(e) Cutting chips,
(f) Steel die stamps,
(g) Stop marks, or
(h) Pipe reducer ripple.
14 Mechanical Tests Required
14.1 Lot—For mechanical testing, a lot is all pipe of the same nominal size and wall thickness (or schedule) which is produced from the same heat of steel and subjected to the same
finishing treatment in a continuous furnace; when final heat treatment is in a batch-type furnace, the lot shall include only that pipe which is heat treated in the same furnace charge.
14.2 Transverse or Longitudinal Tension Test and Flattening Test, Hardness Test, or Bend Test—For material heat treated in a batch-type furnace, tests shall be made on 5 % of the pipe from each treated lot. For small lots, at least 1 pipe shall be tested. For material heat treated by the continuous process, tests shall be made on a sufficient number of pipe to constitute 5 % of the lot, but in no case less than 2 pipe.
14.3 Hardness Test:
14.3.1 The Vickers hardness testing shall be made in accordance with Test Method E92.
14.3.2 For pipes with wall thickness 0.200 in [5.1 mm] or over, either the Brinell or Rockwell hardness test shall be used. When Brinell hardness testing is used, a 10-mm ball with 3000, 1500, or 500-kg load shall be used at the option of the manufacturer.
14.3.3 For pipes with wall thickness 0.065 in. [1.7 mm] or over, but less than 0.200 in [5.1 mm], the Rockwell hardness test shall be used.
14.3.4 For pipes with wall thickness less than 0.065 in [1.7 mm], the hardness test shall not be required.
14.3.5 The Brinell test shall be made, at the option of the manufacturer, on the outside of the pipe near the end, on the outside of a specimen cut from the pipe, or on the wall cross section of a specimen cut from the pipe. This test shall be made so that the center of the impression to the edge of the specimen is at least 2.5 times the diameter of the impression.
14.3.6 The Rockwell hardness test shall, at the option of theww web manufacturer, be made on the inside surface, on the wall cross section, or on a flat of the outside surface..
14.3.7 For pipe of Grades P24, P91, P92, P122, P911, and P36, Brinell, Vickers, or Rockwell hardness tests shall be made on a specimen from each lot.
14.4 Bend Test:
14.4.1 For pipe whose diameter exceeds NPS 25 and whose diameter to wall thickness ratio is 7.0 or less shall be subjected to the bend test instead of the flattening test. Other pipe whose diameter equals or exceeds NPS 10 may be given the bend test in place of the flattening test subject to the approval of the purchaser.
14.4.2 The bend test specimens shall be bent at room temperature through 180° without cracking on the outside of the bent portion. The inside diameter of the bend shall be 1 in. [25 mm].
14.4.3 Test specimens for the bend test specified in 14.4 shall be cut from one end of the pipe and, unless otherwise specified, shall be taken in a transverse direction. One test specimen shall be taken as close to the outer surface as possible
and another from as close to the inner surface as possible. The specimens shall be either 1⁄2 by 1⁄2 in. [12.5 by 12.5 mm] in section or 1 by 1⁄2 in. [25 by 12.5 mm] in section with the corners rounded to a radius not over 1
⁄16 in. [1.6 mm] and need not exceed 6 in. [150 mm] in length. The side of the samples placed in tension during the bend shall be the side closest to the inner and outer surface of the pipe, respectively.
15 Certification
15.1 Certification and test reports, as described in Section 25 of Specification A999/A999M, are required.
15.2 In addition to the information required by Specification A999/A999M, the certification shall state whether or not the pipe was hydrostatically tested. If the pipe was nondestructively examined, the certification shall so state and shall show which practice was followed and what reference discontinuities were used. In addition, the test method information as given in Table 8 shall be appended to the specification number and grade shown on the certification.
16 Product Marking
16.1 In addition to the marking prescribed in Specification A999/A999M, the marking shall include the length, an additional symbol “S”, if the pipe conforms to any of the Supplementary Requirements S1 to S6, the schedule number, if the pipe is ordered to a schedule number, and the heat number or manufacturer’s number by which the heat can be identified. Furthermore, the marking designated in Table 8 to indicate the test method(s) shall be included. Marking may be by stenciling, stamping, or rolling. Pipe that has been weld repaired inoos.co accordance with 7.6 shall be marked “WR.”
17 Government Procurement
17.1 Scale Free Pipe:
17.1.1 When specified in the contract or order, the following requirements shall be considered in the inquiry contract or order, for agencies of the U.S. Government where scale free pipe is required. These requirements shall take precedence if there is a conflict between these requirements and the product specification.
17.1.2 The requirements of Specification A999/A999M for pipe shall be applicable when pipe is ordered to this specification.
17.1.3 Pipe shall be one of the following grades as specified herein:
| Grade | UNS Designation |
| P11 | K11597 |
| P22 | K21590 |
| P5 | K41545 |
| Ultrasonic | Flux Leakage | Eddy Current | Hydrostatic | Marking |
| YES | NO | NO | NO | UT |
| NO | YES | NO | NO | FL |
| NO | NO | YES | NO | EC |
| YES | NO | NO | YES | UT/TEST PRESSURE |
| NO | YES | NO | YES | FL/TEST PRESSURE |
| NO | NO | YES | YES | EC/TEST PRESSURE |
| 17.1.4.1 Pipe shall be ordered to nominal pipe size and schedule specified in ASME B36.10MExample: A335/A335M Pipe P-11 NPS 12 Sch 40 | 17.1.5 Ordering Information—Orders for material under this specification shall include the following in addition to the requirements of Section 3:17.1.5.1 Pipe or tube,17.1.5.2 Part number,17.1.5.3 Ultrasonic inspection, if required,17.1.5.4 If shear wave test is to be conducted in two opposite circumferential directions, and17.1.5.5 Level of preservation and packing required. | |
| Specification Number | ASTM A335/A335M | |
| Pipe | P | |
| Grade | P-11 | |
| NPS | 12 | |
| Wall | 0.375 | |
| 17.1.4.2 | ||
| Specification Number | ASTM A335/A 335 M | 18. Keywords18.1 alloy steel pipe; high temperature service; seamless steel pipe; steel pipe; temperature service applications |
| Tube | T | |
| Grade | P-11 | |
| Outside Diameter | 0.250 | |
| Wall | 0.035 | |
SUPPLEMENTARY REQUIREMENTS
One or more of the following supplementary requirements shall apply only when specified in the purchase order. The purchaser may specify a different frequency of test or analysis than is provided in the supplementary requirement. Subject to agreement between the purchaser and manufacturer, retest and retreatment provisions of these supplementary requirements may also be modified.
S1. Product Analysis
S1.1 Product analysis shall be made on each length of pipe. Individual lengths failing to conform to the chemical composition requirements shall be rejected.
S2. Transverse Tension Tests
S2.1 A transverse tension test shall be made on a specimen. b from one end or both ends of each pipe NPS 8 and over. If thiswww we supplementary requirement is specified, the number of tests per pipe shall also be specified. If a specimen from any length fails to meet the required tensile properties (tensile, yield, and elongation), that length shall be rejected subject to retreatment in accordance with Specification A999/A999M and satisfactory retest.
S3. Flattening Test
S3.1 The flattening test of Specification A999/A999M shall be made on a specimen from one end or both ends of each pipe. Crop ends may be used. If this supplementary requirement is specified, the number of tests per pipe shall also be specified. If a specimen from any length fails because of lack of ductility prior to satisfactory completion of the first step of the flattening test requirement, that pipe shall be rejected subject to retreatment in accordance with Specification A999/A999M and satisfactory retest. If a specimen from any length of pipe fails because of a lack of soundness that length shall be rejected, unless subsequent retesting indicates that the remaining length is sound. The bend test of 13.2 shall be substituted for the flattening test for pipe whose diameter exceeds NPS 25 and whose diameter to wall thickness ratio is 7.0 or less.
S4. Metal Structure and Etching Tests
S4.1 The steel shall be homogeneous as shown by etching tests conducted in accordance with the appropriate portions of Method E381. Etching tests shall be made on a cross section from one end or both ends of each pipe and shall show sound
and reasonably uniform material free from injurious laminations, cracks, and similar objectionable defects. If this supplementary requirement is specified, the number of tests per pipe required shall also be specified. If a specimen from any length shows objectionable defects, the length shall be rejected, subject to removal of the defective end and subsequent retests indicating the remainder of the length to be sound and reasonably uniform material.oos NOTE S4.1—Pending development of etching methods applicable to the. product covered by this specification, it is recommended that the Recommended Practice for a Standard Macro Etch Test for Routine Inspection of Iron and Steel, described in the Metals Handbook, Am. Soc. for Metals, 1948 edition, p. 389, be followed.
S5. Photomicrographs
S5.1 When requested by the purchaser and so stated in the order, the manufacturer shall furnish one photomicrograph at 100 diameters from a specimen of pipe in the as-finished condition for each individual size and wall thickness from each heat, for pipe NPS 3 and over. Such photomicrographs shall be suitably identified as to pipe size, wall thickness, and heat. No photomicrographs for the individual pieces purchased shall be required except as specified in Supplementary Requirement S6. Such photomicrographs are for information only, to show the actual metal structure of the pipe as finished.
S6. Photomicrographs for Individual Pieces
S6.1 In addition to the photomicrographs required in accordance with Supplementary Requirement S5, the purchaser may specify that photomicrographs shall be furnished from each end of one or more pipes from each lot of pipe NPS 3 and larger in the as-finished condition. The purchaser shall state in the order the number of pipes to be tested from each lot. When photomicrographs are required on each length, the photomicrographs from each lot of pipe in the as-finished condition which may be required under Supplementary Requirement S5
may be omitted. All photo-micrographs required shall be properly identified as to heat number, size, and wall thickness of pipe from which the section was taken. Photomicrographs shall be further identified to permit association of each photomicrograph with the individual length of pipe it represents.
S7. Alternative Heat Treatment—Grade P91
S7.1 Grade P91 shall be normalized in accordance with Table 2 and tempered at a temperature, to be specified by the
purchaser, less than 1350 °F [730 °C]. It shall be purchaser’s responsibility to subsequently temper at 1350-1470 °F [730-800 °C] minimum. All mechanical tests shall be made on material heat treated in accordance with Table 2. The certification shall reference this supplementary requirement indicating the tempering temperature applied. The notation “S7” shall be included with the required marking of the pipe.
SUMMARY OF CHANGES
Committee A01 has identified the location of selected changes to this specification since the last issue, A335/A335M–10b, that may impact the use of this specification. (Approved October 1, 2011)
(1) Added new 2.3 to Referenced Documents to add AWS specifications and renumbered subsequent paragraphs.
(2) Inserted new 7.6.1 and 7.6.2 to add process and consumable chemistry restrictions for P91 weld repairs and weld consumable chemistry restrictions for P92, P122, and P911, and renumbered subsequent paragraphs. Committee A01 has identified the location of selected changes to this specification since the last issue, A335/A335M–10a, that may impact the use of this specification. (Approved November 1, 2010)
(1) Rewrote Section 12 Hydrostatic Test and Section 13 Nondestructive Examination, thus making the nondestructive test mandatory and the hydrotest optional. Revised Table 8 to ensure coherence with these changes.
(2) Modified the chemical composition of grade P23 in Table 1.
Committee A01 has identified the location of selected changes to this specification since the last issue, A335/A335M–10, that may impact the use of this specification. (Approved May 1, 2010). .
(1) Added new 9.5 dealing with compliance of the tensile and hardness properties at mid-thickness for Grade P91 quenched and tempered.
(2) Added a citation for Footnote E to Grade P92 in Table 2. (3) Added new Grade P24 to 7.6.5, 9.3, 14.3.7, and Tables 1-5.
Committee A01 has identified the location of selected changes to this specification since the last issue, A335/A335M–09a, that may impact the use of this specification. (Approved April 1, 2010)
(1) Added new 15.1 to make the certification and test reports mandatory in all cases and renumbered subsequent paragraphs. (2) Revised 14.3 to permit performance of the hardness testing.
(3) Moved the text of Notes 6 and 7 into the main body of the standard.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards, at the address shown below.