1 General
1.1 Scope ............ ...... 1
1.2 Purpose ........... ...... 1
1.3 Application.......... ... 2
2 References .......... ..... 2
3 Definitions
......... ..... 3
4 Requirements
4.1 Permeation ......... ...... 5
4.2 Workmanship ........... ...... 6
4.3 Cell Classification System.................. 6
4.4 Materials ...... ... 7
4.5 Pipe Dimensions ........... .......... 7
4.6 Pressure Classes ......... 13
4.7 Stiffness Classes......... . 14
4.8 Long-Term Ring-Bending Strain ..... 14
4.9 Joint Types and Requirements ......... 14
5 Verification
5.1 Inspection and Testing .................... 16
5.2 Rejection and Retesting................... 26
6 Delivery
6.1 Marking ............. ........ 27
6.2 Shipping............. ......... 27
6.3 Affidavit of Compliance .................. 27
Tables
1 Dimensions for Inside Diameter Series Pipe ......... Metric Dimensions for Inside Diameter (ID) Series Pipe ........................... 9
3 Dimensions for Outside Diameter (OD) Series Pipe With Steel-Pipe Equivalent (IPS) ODs .
4 Dimensions for Outside Diameter (OD) Series Pipe With Cast-Iron (Ductile-Iron)-Pipe Equivalent ODs .. 11
5 Metric Dimensions for Outside Diameter (OD) Series Pipe ........ 12
6 Metric Dimensions for Outside Diameter (OD) Series Pipe With Ductile-Iron Pipe Equivalent ODs ........................ 13
7 Hydrostatic Leak Test Pressure Requirements ............. 17
8 Minimum Pipe Stiffness Requirements for 5 Percent Deflection............. 18
9 Ring Deflection Without Damage or Structural Failure ...................... 18
10.A Minimum Hoop Strength Requirements (from Eq 2) (lbf/in. of width)..... ............ 21
10.B Minimum Hoop Tensile Strength Requirements (from Eq 2) (N/mm of width).. .......... 22
11.A Minimum Axial Strength Requirements (lbf /in. of circumference).... ..... 23
11.B Minimum Axial Strength Requirements (N/mm of circumference).... ...... 24
12 Beam Strength Requirements ............ 25
13 Minimum Axial Compressive Strength Requirements ............................ 26
This foreword is for information only and is not a part of ANSI*/AWWA C950.
I. Introduction.
I.A. Background. This standard provides direction and guidance in selecting and purchasing fiberglass pipe for use as pressure pipe in water distribution (including services) and transmission systems for both aboveground and belowground installations. This standard describes 1-in. through 156-in. (25-mm through 4,000-mm) diameter pressure pipes. The primary materials used are thermosetting polyester or epoxy resins, glass-fiber reinforcement, and, if used, aggregate. There are nine pressure classes, which range from 50 psi through 450 psi (345 kPa through 3,103 kPa), in 50-psi (345-kPa) increments. Stiffness classes described are 9, 18, 36, and 72 psi (62, 124, 248, and 496 kPa). This standard may be used to the extent applicable for other sizes, pressure classes, and stiffness classes.
I.B. History. In June 1971, the AWWA Engineering and Construction Technical and Professional Committee organized the Reinforced Plastics Committee to evaluate both the use of reinforced plastics in the water-supply industry and the need for appropriate AWWA standards. The Reinforced Plastics Committee found sufficient use and interest to support a recommendation that a standard be developed for fiberglass pipe. The Standards Council authorized the formation of the Standards Committee on Thermosetting Fiberglass Reinforced Plastic Pipe in October 1972, and committee organization was completed in December 1974. The first edition of the standard was approved by the AWWA Board of Directors on Jan. 25, 1981. Subsequent editions were approved on June 23, 1988; Jan. 22, 1995; June 17, 2001; and Jan. 21, 2007. This edition was approved on Jan. 20, 2013 I.C. Acceptance. In May 1985, the US Environmental Protection Agency (USEPA) entered into a cooperative agreement with a consortium led by NSF International (NSF) to develop voluntary third-party consensus standards and a certification program for direct and indirect drinking water additives. Other members of the original consortium included the American Water Works Association Research Foundation (AwwaRF, now Water Research Foundation) and the Conference of State Health and Environmental Managers (COSHEM). The American Water Works Association and the Association of State Drinking Water Administrators (ASDWA) joined later.
* American National Standards Institute, 25 West 43rd Street, Fourth Floor, New York, NY 10036.
In the United States, authority to regulate products for use in, or in contact with, drinking water rests with individual states.* Local agencies may choose to impose requirements more stringent than those required by the state. To evaluate the health effects of products and drinking water additives from such products, state and local agencies may use various references, including
1. An advisory program formerly administered by USEPA, Office of Drinking Water, discontinued on Apr. 7, 1990.
2. Specific policies of the state or local agency.
3. Two standards developed under the direction of NSF, NSF†/ANSI‡ 60, Drinking Water Treatment Chemicals—Health Effects, and NSF/ANSI 61, Drinking Water System Components—Health Effects.
4. Other references, including AWWA standards, Food Chemicals Codex, Water Chemicals Codex,§ and other standards considered appropriate by the state or local agency.
Various certification organizations may be involved in certifying products in accordance with NSF/ANSI 61. Individual states or local agencies have authority to accept or accredit certification organizations within their jurisdiction. Accreditation of certification organizations may vary from jurisdiction to jurisdiction. Annex A, “Toxicology Review and Evaluation Procedures,” to NSF/ANSI 61 does not stipulate a maximum allowable level (MAL) of a contaminant for substances not regulated by a USEPA final maximum contaminant level (MCL). The MALs of an unspecified list of “unregulated contaminants” are based on toxicity testing guidelines (noncarcinogens) and risk characterization methodology (carcinogens). Use of Annex A procedures may not always be identical, depending on the certifier.
ANSI/AWWA C950 does not address additives requirements. Thus, users of this standard should consult the appropriate state or local agency having jurisdiction in order to
1. Determine additives requirements, including applicable standards.
2. Determine the status of certifications by all parties offering to certify products for contact with, or treatment of, drinking water.
3. Determine current information on product certification.
* Persons outside the United States should contact the appropriate authority having jurisdiction. †NSF International, 789 N. Dixboro Road, Ann Arbor, MI 48105. ‡American National Standards Institute, 25 West 43rd Street, Fourth Floor, New York, NY 10036. §Both publications available from National Academy of Sciences, 500 Fifth Street, N.W., Washington, DC 20001.
II. Special Issues.
II.A. Nominal Metric Pipe Sizes, Dimensions, and Tolerances. Nominal metric pipe sizes, dimensions, and tolerances were obtained from ISO and CEN product standards for fiberglass pipes.
III. Use of This Standard. It is the responsibility of the user of an AWWA standard to determine that the products described in that standard are suitable for use in the particular application being considered.
III.A. Purchaser Options and Alternatives. The following items should be covered by the purchaser:
1. Standard used—that is, ANSI/AWWA C950, Fiberglass Pressure Pipe, of latest revision.
2. Specific service and installation considerations.
3. Lineal feet of each pressure and stiffness class and size.
4. Details of other federal, state or provincial, and local requirements (Sec. 4.4.1).
5. Pipe diameter size and series (Sec. 4.5.1).
6. Pressure classes (Sec. 4.6).
7. Stiffness classes (Sec. 4.7).
8. Whether plant inspection is required (Sec. 5.1.1).
The purchaser may also specify the following:
1. Line layout showing pressure zones, including applicable design and transient pressures within zones and points of change between zones.
2. Cell classification (Sec. 4.3).
3. Standard laying lengths (Sec. 4.5.2).
4. Joint configuration (Sec. 4.9).
III.B. Manufacturer Options and Alternatives. The following items should be provided by the manufacturer:
1. Nominal wall thickness.
2. Weight.
3. Total quantity of jointing materials and field allowances.
4. Cell classification (Sec. 4.3).
5. Stiffness class (Sec. 4.7).
6. Joint details (Sec. 4.9).
When requested by the purchaser, it is understood the manufacturer will also supply the following:
1. Special design calculations.
2. Special lengths (Sec. 4.5.2).
3. Special preparations needed for shipment (Sec. 6.2).
4. Affidavit of compliance (Sec. 6.3).
III.C. Modification to Standard. Any modifications to the provisions, definitions, or terminology in this standard must be provided by the purchaser or manufacturer.
IV. Major Revisions. Major revisions made to the standard in this edition include the following:
1. Wording changes to clarify “production run” and materials permitted.
2. The mandatory hydrotesting diameter was increased from 54 in. to 96 in.
3. The hydrotesting pressure for diameters greater than 54 in. is 1.5× to better reflect current equipment capabilities available in the industry.
V. Comments. If you have any comments or questions about this standard, please call AWWA Engineering & Technical Services at 303.794.7711, FAX at 303.795.7603, write to the group at 6666 West Quincy Avenue, Denver, CO 80235-3098; or email standards@awwa.org.
AWWA Standard
SECTION 1: General
Sec. 1.1 Scope
This standard describes the fabrication and the testing of nominal 1-in. through 156-in. (25-mm through 4,000-mm) fiberglass pipe and joining systems for use in both aboveground and belowground water systems. Service and distribution piping systems and transmission piping systems are included. Both glass-fiber-reinforced thermosetting-resin pipe (RTRP) and glass-fiberreinforced polymer-mortar pipe (RPMP) are fiberglass pipes. Epoxy-resin and polyester-resin systems are described, and commercial-grade glass-fiber is specified as the reinforcement material in the pipe wall. Liner materials incorporated include thermosetting or thermoplastic resin, reinforced or unreinforced, with or without fillers. Pressure classes described are 50, 100, 150, 200, 250, 300, 350, 400, and 450 psig (345, 689, 1,034, 1,379, 1,724, 2,069, 2,414, 2,759, and 3,103 kPa). Stiffness classes described are 9, 18, 36, and 72 psi (62, 124, 248, and 496 kPa). This standard may be used to the extent applicable for other diameters, pressure classes, and stiffness classes. For information on design, hydraulics, and installation, refer to AWWA Manual M45, Fiberglass Pipe Design.
Sec. 1.2 Purpose
The purpose of this standard is to provide the minimum requirements for fiberglass pressure pipe, including design, fabrication, and testing requirements.
Sec. 1.3 Application
This standard can be referenced in specifications for purchasing and receiving fiberglass pressure pipe. This standard can be used as a guide for manufacturing this type of fiberglass pressure pipe. The stipulations of this standard apply when this document has been referenced and then only to fiberglass pressure pipe.
SECTION 2: References
This standard references the following documents. In their latest editions, these documents form a part of this standard to the extent specified within the standard. In case of conflict, the requirements of this standard shall prevail. ASTM* D638—Standard Test Method for Tensile Properties of Plastics.
ASTM D695—Standard Test Method for Compressive Properties of Rigid Plastics. (historical standard)
ASTM D1599— Standard Test Method for Resistance to Short Time Hydrau-©lic Pressure of Plastic Pipe, Tubing, and Fittings. ASTM D2105—Standard Test Method for Longitudinal Tensile Properties of Fiberglass (Glass-Fiber-Reinforced Thermosetting-Resin) Pipe and Tube.
ASTM D2290—Standard Test Method for Apparent Hoop Tensile Strength of Plastic or Reinforced Plastic Pipe by Split Disk Method. ASTM D2412—Standard Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading.
ASTM D2992—Standard Practice for Obtaining Hydrostatic or Pressure Design Basis for Fiberglass (Glass-Fiber-Reinforced Thermosetting-Resin) Pipe and Fittings. ASTM D3517—Standard Specification for Fiberglass (Glass-Fiber-Reinforced Thermosetting-Resin) Pressure Pipe.
ASTM D3567—Standard Practice for Determining Dimensions of Fiberglass (Glass-Fiber-Reinforced Thermosetting-Resin) Pipe and Fittings. ASTM D3681—Standard Test Method for Chemical Resistance of Fiberglass (Glass-Fiber-Reinforced Thermosetting-Resin) Pipe in a Deflected Condition.
ASTM D4161—Standard Specification for Fiberglass (Glass-Fiber-Reinforced Thermosetting-Resin) Pipe Joints Using Flexible Elastomeric Seals. ASTM D5365—Standard Test Method for Long-Term Ring-Bending Strain of Fiberglass (Glass-Fiber-Reinforced Thermosetting-Resin) Pipe. ASTM F477—Standard Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe. AWWA Manual M45, Fiberglass Pipe Design.
SECTION 3: Definitions
The following definitions shall apply in this standard:
1. Aggregate: Siliceous sand with minimum 96 percent silicon (Si) compounds and maximum 2 percent passing No. 200 sieve.
2. Centrifugal casting: A process used to manufacture tubular goods by applying resin and reinforcement to the inside of a mold that is rotated and heated, subsequently polymerizing the resin system. The outside diameter (OD) of the finished pipe is determined by the inside diameter (ID) of the mold tube. The ID ©of the finished pipe is determined by the amount of material introduced into the mold. Other materials that will not adversely affect the laminate performance may be introduced in the process during manufacture of the pipe.
3. Constructor: The party that provides the work and materials for placement or installation.
4. Epoxy resin (thermosetting): A polymer containing two or more threemembered rings, each consisting of one oxygen and two carbon atoms. The polymer is cured by cross-linking with an amine or anhydride hardener, with or without heat, catalyst, or both.
5. Fiberglass pipe: A tubular product containing glass-fiber reinforcements embedded in or surrounded by cured thermosetting resin. The composite structure may contain aggregate, granular or platelet fillers, thixotropic agents, and pigments or dyes. Thermoplastic or thermosetting liners or coatings may be included.
6. Filament winding: A process used to manufacture tubular goods by winding continuous glass-fiber roving or roving tape onto the outside of a mandrel or core pipe liner in a predetermined pattern under controlled tension. The roving may be saturated with liquid resin or preimpregnated with partially cured resin. Subsequent polymerization of the resin system may require application of heat. The ID of the finished pipe is fixed by the mandrel diameter or the inner diameter of the core pipe liner. The OD of the finished pipe is determined by the amount of material that is wound on the mandrel or core pipe liner. Other materials may
be introduced in the process during the manufacture of the pipe, which will not adversely affect the laminate performance.
7. Fixed end: The end of a pipe test specimen with an end closure configuration such that internal pressure produces only hoop and radial stresses in a straight pipe test specimen. Longitudinal thrust is absorbed by separate means, such as tie-rods, etc.
8. Flexible joint: A joint that is capable of axial displacement or angular rotation.
9. Free end: The end of a pipe test specimen with an end closure configuration such that internal pressure produces longitudinal stresses in addition to hoop and radial stresses in the pipe test specimen.
10. Glass fabric: A bidirectional fabric reinforcing material made by the weaving of glass-fiber yarn.
11. Glass fibers: A commercial grade of glass fibers compatible with the resin used.
12. Joint restraint: A separate external device or structure that is assembled or constructed around a joint to provide restraint to longitudinal tensile forces.
13. Liner: A filled or unfilled thermoplastic or thermosetting resin layer, nonreinforced or reinforced, that forms the interior surface of the pipe.
14. Manufacturer: The party that manufactures, fabricates, or produces materials or products.
15. Mat: A fibrous material consisting of random-oriented, chopped, or swirled filaments loosely held together with a binder.
16. Polyester resin (thermosetting): An ethylenic unsaturated polymer with two or more ester groups, dissolved in a reactive diluent with vinyl unsaturation. The polymer is cured by cross-linking using a free-radical-initiated curing mechanism, such as peroxide catalyst and heat.
17. Purchaser: The person, company, or organization that purchases materials or work to be performed.
18. Purchaser’s agent: The authorized representative of the purchaser who is entrusted with the inspection of materials and production records and the observance of production operations and quality-control tests to ensure the products comply with the requirements of this standard and of the purchaser.
19. Reinforced polymer-mortar pipe (RPMP): A fiberglass pipe with aggregate.
20. Reinforced thermosetting-resin pipe (RTRP): A fiberglass pipe without aggregate.
21. Resin: Any of a class of solid or pseudosolid organic materials, often of high molecular weight, with no definite melting point. In the broad sense, the term is used to designate any polymer that is a basic material for plastics.
22. Restrained joint: Pipe joint capable of withstanding internal pressure and longitudinal tensile loads.
23. Rigid joint: A joint that is not capable of axial displacement or angular rotation.
24. Roving: A collection of parallel glass strands or filaments, coated with a finish or coupling agent to improve compatibility with resins, gathered without mechanical twist. Roving may be processed in a continuous or chopped form.
25. Stiffness class: The nominal stiffness of a specified pipe. (The stiffness class is determined as specified in Sec. 4.7.)
26. Supplier: The party that supplies materials or services. A supplier may or may not be the manufacturer.
27. Surface layer: A filled or unfilled resin layer, nonreinforced or reinforced, that is applied to the exterior surface of the pipe structural wall.
28. Surfacing mat: A thin mat of fine fibers used primarily to produce a smooth surface on a reinforced plastic.
29. Tape: A unidirectional glass-fiber reinforcement consisting of rovings knitted or woven into ribbon form.
30. Thermoplastic resin: A plastic that can be repeatedly softened by heating and hardened by cooling and that in the softened state can be fused or shaped by flow.
31. Thermosetting resin: A plastic that, after having been cured by heat or other means, is substantially infusible and insoluble.
32. Unrestrained joint: Pipe joint capable of withstanding internal pressure but not longitudinal tensile loads.
33. Woven roving: A glass-fiber fabric reinforcing material made by the weaving of glass-fiber roving.
SECTION 4: Requirements
Sec. 4.1 Permeation
The selection of materials is critical for water service and distribution piping in locations where there is likelihood the pipe will be exposed to significant concentrations of pollutants composed of low-molecular-weight petroleum products or
organic solvents or their vapors. Documented research has shown that pipe materials (such as polyethylene and polyvinyl chloride) and elastomers, such as those used in jointing gaskets and packing glands, are subject to permeation by lowermolecular-weight organic solvents or petroleum products. If a water pipe must pass through such a contaminated area or an area subject to contamination, consult with the manufacturer regarding permeation of pipe walls, jointing materials, and so forth, before selecting materials for use in that area.
Sec. 4.2 Workmanship
The pipe shall be free from defects, including indentations, delaminations, bubbles, pinholes, cracks, pits, blisters, foreign inclusions, and resin-starved areas that, because of their nature, degree, or extent, detrimentally affect the strength and serviceability of the pipe. The pipe shall be as uniform as commercially practicable in color, opacity, density, and other physical properties.
Sec. 4.3 Cell Classification System
This standard describes products defined by a cell classification system and ©identifies the method of manufacture (type), construction and materials (grade), and liner construction (liner). The types, grades, and liners are identified in the following paragraphs. It should be noted that all possible combinations of types, grades, and liners may not be commercially available.
4.3.1 Types. The product type is determined by the method of manufacture, as follows:
Type I: Filament wound.
Type II: Centrifugally cast.
4.3.2 Grades. The product grade is determined by construction (glassfiber-reinforced or glass-fiber-reinforced mortar) and materials (epoxy or polyester), as follows:
Grade 1: Glass-fiber-reinforced epoxy (RTRP epoxy).
Grade 2: Glass-fiber-reinforced polyester (RTRP polyester).
Grade 3: Glass-fiber-reinforced epoxy mortar (RPMP epoxy).
Grade 4: Glass-fiber-reinforced polyester mortar (RPMP polyester).
4.3.3 Liners. The product-liner classification is determined by whether or not a liner is used and, if used, whether it is a thermoplastic, reinforced, or nonreinforced thermoset. Classification of liners is as follows:
Liner A: No liner.
Liner B: Thermoplastic liner.
Liner C: Reinforced thermoset polyester liner.
Liner D: Nonreinforced thermoset polyester liner.
Liner E: Reinforced thermoset epoxy liner.
Liner F: Nonreinforced thermoset epoxy liner.
Sec. 4.4 Materials
The thermosetting resins, glass-fiber reinforcement, fillers, and other materials, when combined as a composite structure, shall produce piping products that meet the performance requirements of this standard as specified in Sec. 5.1.2.
4.4.1 General. Materials shall comply with the requirements of the Safe Drinking Water Act and other federal regulations for potable water, wastewater, and reclaimed water systems as applicable.
4.4.2 Certification. Fiberglass pipe intended for use in the transport of potable water shall be evaluated and certified for this use as required by the local authority.* The seal or mark of the laboratory that evaluates the pipe should be included on the fiberglass pipe.
4.4.3 Gaskets and lubricants. Gaskets and lubricants shall be made from materials that (1) are compatible with the plastic materials and with each other when used together; (2) will not support the growth of bacteria; and (3) will not adversely affect the potable qualities of water.
Sec. 4.5 Pipe Dimensions
4.5.1 Diameters. Pipe diameters and tolerances shall be as shown in Tables 1–6 when measured in accordance with ASTM D3567. These tables include dimensions for pipe based on both inside and outside diameters. In the latter case, tables are provided for steel-pipe equivalent ODs, cast-iron (ductile-iron)-pipe equivalent ODs, and metric ODs commonly used in international practice. As a group, the tables cover nominal pipe sizes 1 in. through 156 in. (25 mm through 4,000 mm); individual tables cover only a portion of the total range. Other dimensions for pipe are acceptable if agreed to between the purchaser and the manufacturer.
4.5.2 Length. Pipe shall be provided in standard laying lengths as agreed on by the purchaser and manufacturer. A maximum of 15 percent of the footage of each pipe size may be provided in random lengths. Each random length provided shall not vary by more than 25 percent from the standard laying length specified, except for special orders.
* See Sec. I.C, Acceptance, in the foreword for additional guidance.
| Nominal Pipe Size | Inside Diameter | Tolerance | |||
| in. | (mm)* | in. | (mm) | in. | (mm) |
| 1 | (25) | 1.00 | (25.4) | ±0.06 | (±1.5) |
| 11⁄2 | (40) | 1.50 | (38.1) | ±0.06 | (±1.5) |
| 2 | (50) | 2.00 | (50.8) | ±0.06 | (±1.5) |
| 21⁄2 | (65) | 2.50 | (63.5) | ±0.06 | (±1.5) |
| 3 | (80) | 3.00 | (76.2) | ±0.12 | (±3.0) |
| 4 | (100) | 4.00 | (101.6) | ±0.12 | (±3.0) |
| 6 | (150) | 6.00 | (152.4) | ±0.25 | (±6.3) |
| 8 | (200) | 8.00 | (203.2) | ±0.25 | (±6.3) |
| 10 | (250) | 10.00 | (254.0) | ±0.25 | (±6.3) |
| 12 | (300) | 12.00 | (304.8) | ±0.25 | (±6.3) |
| 14 | (350) | 14.00 | (355.6) | ±0.25 | (±6.3) |
| 15 | (375) | 15.00 | (381.0) | ±0.25 | (±6.3) |
| 16 | (400) | 16.00 | (406.4) | ±0.25 | (±6.3) |
| 18 | (450) | 18.00 | (457.2) | ±0.25 | (±6.3) |
| 20 | (500) | 20.00 | (508.0) | ±0.25 | (±6.3) |
| 21 | (550) | 21.00 | (533.4) | ±0.25 | (±6.3) |
| 24 | (600) | 24.00 | (609.6) | ±0.25 | (±6.3) |
| 27 | (700) | 27.00 | (685.8) | ±0.27 | (±6.9) |
| 30 | (800) | 30.00 | (762.0) | ±0.30 | (±7.6) |
| 33 | (850) | 33.00 | (838.2) | ±0.33 | (±8.4) |
| 36 | (900) | 36.00 | (914.4) | ±0.36 | (±9.1) |
| 39 | (1,000) | 39.00 | (990.6) | ±0.39 | (±9.9) |
| 42 | (1,100) | 42.00 | (1,066.8) | ±0.42 | (±10.7) |
| 45 | (1,150) | 45.00 | (1,143.0) | ±0.45 | (±11.4) |
| 48 | (1,200) | 48.00 | (1,219.2) | ±0.48 | (±12.2) |
| 51 | (1,300) | 51.00 | (1,295.4) | ±0.51 | (±13.0) |
| 54 | (1,400) | 54.00 | (1,371.6) | ±0.54 | (±13.7) |
| 60 | (1,500) | 60.00 | (1,524.0) | ±0.60 | (±15.2) |
| 66 | (1,700) | 66.00 | (1,676.4) | ±0.66 | (±16.8) |
| 72 | (1,800) | 72.00 | (1,828.8) | ±0.72 | (±18.3) |
| 78 | (2,000) | 78.00 | (1,981.2) | ±0.78 | (±19.8) |
| 84 | (2,200) | 84.00 | (2,133.6) | ±0.84 | (±21.3) |
| 90 | (2,300) | 90.00 | (2,286.0) | ±0.90 | (±22.9) |
| 96 | (2,400) | 96.00 | (2,438.4) | ±0.96 | (±24.4) |
| 102 | (2,600) | 102.00 | (2,590.8) | ±1.00 | (±25.4) |
| 108 | (2,800) | 108.00 | (2,743.2) | ±1.00 | (±25.4) |
| 114 | (2,900) | 114.00 | (2,895.6) | ±1.00 | (±25.4) |
| 120 | (3,000) | 120.00 | (3,048.0) | ±1.00 | (±25.4) |
| 132 | (3,400) | 132.00 | (3,352.8) | ±1.00 | (±25.4) |
| 144 | (3,600) | 144.00 | (3,657.6) | ±1.00 | (±25.4) |
| 156 | (4,000) | 156.00 | (3,962.4) | ±1.00 | (±25.4) |
| Nominal Pipe Size | Range mm | Inside Diameter US Customary Unit Equivalent† in. | Tolerance | ||||
| Metric Dimension* | Closest US Customary Unit Equivalent | ||||||
| mm | in. | Minimum | Maximum | Minimum | Maximum | mm | (in.) |
| 25 | 1 | 23.5 | 26.5 | 0.93 | 1.04 | ±1.5 | (±0.06) |
| 40 | 11⁄2 | 38 | 42.0 | 1.50 | 1.65 | ±1.5 | (±0.06) |
| 50 | 2 | 48 | 52.0 | 1.89 | 2.05 | ±1.5 | (±0.06) |
| 80 | 3 | 78 | 82.0 | 3.07 | 3.23 | ±1.5 | (±0.06) |
| 100 | 4 | 97 | 103 | 3.82 | 4.06 | ±1.5 | (±0.06) |
| 150 | 6 | 147 | 153 | 5.79 | 6.02 | ±1.5 | (±0.06) |
| 200 | 8 | 196 | 204 | 7.72 | 8.03 | ±1.5 | (±0.06) |
| 250 | 10 | 246 | 255 | 9.69 | 10.04 | ±1.5 | (±0.06) |
| 300 | 12 | 296 | 306 | 11.65 | 12.05 | ±1.8 | (±0.07) |
| 350 | 14 | 346 | 357 | 13.62 | 14.06 | ±2.1 | (±0.08) |
| 400 | 16 | 396 | 408 | 15.59 | 16.06 | ±2.4 | (±0.09) |
| 450 | 18 | 446 | 459 | 17.56 | 18.07 | ±2.7 | (±0.11) |
| 500 | 20 | 496 | 510 | 19.53 | 20.08 | ±3.0 | (±0.12) |
| 600 | 24 | 595 | 612 | 23.43 | 24.09 | ±3.6 | (±0.14) |
| 700 | 27 | 695 | 714 | 27.36 | 28.11 | ±4.2 | (±0.17) |
| 800 | 30 | 795 | 816 | 31.30 | 32.13 | ±4.2 | (±0.17) |
| 900 | 36 | 895 | 918 | 35.24 | 36.14 | ±4.2 | (±0.17) |
| 1,000 | 39 | 995 | 1,020 | 39.17 | 40.16 | ±4.2 | (±0.17) |
| 1,200 | 48 | 1,195 | 1,220 | 47.05 | 48.03 | ±5.0 | (±0.20) |
| 1,400 | 54 | 1,395 | 1,420 | 54.92 | 55.91 | ±5.0 | (±0.20) |
| 1,600 | 63 | 1,595 | 1,620 | 62.80 | 63.78 | ±5.0 | (±0.20) |
| 1,800 | 72 | 1,795 | 1,820 | 70.67 | 71.65 | ±5.0 | (±0.20) |
| 2,000 | 78 | 1,995 | 2,020 | 78.54 | 79.53 | ±5.0 | (±0.20) |
| (2,200) | 84 | 2,195 | 2,220 | 86.42 | 87.40 | ±5.0 | (±0.20) |
| 2,400 | 96 | 2,395 | 2,420 | 94.29 | 95.28 | ±6.0 | (±0.24) |
| (2,600) | 102 | 2,595 | 2,620 | 102.17 | 103.15 | ±6.0 | (±0.24) |
| 2,800 | 108 | 2,795 | 2,820 | 110.04 | 111.02 | ±6.0 | (±0.24) |
| (3,000) | 120 | 2,995 | 3,020 | 117.91 | 118.90 | ±6.0 | (±0.24) |
| 3,200 | 126 | 3,195 | 3,220 | 125.79 | 126.77 | ±6.0 | (±0.24) |
| (3,400) | 132 | 3,395 | 3,420 | 133.66 | 134.65 | ±7.0 | (±0.28) |
| 3,600 | 144 | 3,595 | 3,620 | 141.54 | 142.52 | ±7.0 | (±0.28) |
| 3,800 | 150 | 3,795 | 3,820 | 149.41 | 150.39 | ±7.0 | (±0.28) |
| 4,000 | 156 | 3,995 | 4,020 | 157.28 | 158.27 | ±7.0 | (±0.28) |
| Nominal Pipe Size | Outside Diameter | Tolerance | |||
| in. | (mm)* | in. | (mm) | in. | (mm) |
| 1 | (25) | 1.315 | (33.40) | +0.060 | (+1.52) |
| -0.016 | (-0.41) | ||||
| 11⁄2 | (40) | 1.900 | (48.26) | +0.060 | (+1.52) |
| -0.018 | (-0.46) | ||||
| 2 | (50) | 2.375 | (60.33) | +0.060 | (+1.52) |
| -0.018 | (-0.46) | ||||
| 21⁄2 | (65) | 2.875 | (73.03) | +0.060 | (+1.52) |
| -0.018 | (-0.46) | ||||
| 3 | (80) | 3.500 | (88.90) | +0.060 | (+1.52) |
| -0.018 | (-0.46) | ||||
| 4 | (100) | 4.500 | (144.30) | +0.060 | (+1.52) |
| -0.018 | (-0.46) | ||||
| 6 | (150) | 6.625 | (168.28) | +0.066 | (+1.68) |
| -0.028 | (-0.71) | ||||
| 8 | (200) | 8.625 | (219.08) | +0.086 | (+2.18) |
| -0.040 | (-1.02) | ||||
| 10 | (250) | 10.750 | (273.05) | +0.108 | (+2.74) |
| -0.048 | (-1.22) | ||||
| 12 | (300) | 12.750 | (323.85) | +0.128 | (+3.25) |
| -0.056 | (-1.42) | ||||
| 14 | (350) | 14.000 | (355.60) | +0.140 | (+3.56) |
| -0.062 | (-1.57) | ||||
| 16 | (400) | 16.000 | (406.40) | +0.160 | (+4.06) |
| -0.070 | (-1.78) | ||||
| Nominal Pipe Size | Outside Diameter | Tolerance | |||
| in. | (mm)* | in. | (mm) | in. | (mm) |
| 2 | (50) | 2.50 | (63.5) | +0.05 | (+1.3) |
| -0.05 | (-1.3) | ||||
| 3 | (80) | 3.96 | (100.6) | +0.06 | (+1.5) |
| -0.06 | (-1.5) | ||||
| 4 | (100) | 4.80 | (121.9) | +0.06 | (+1.5) |
| -0.06 | (-1.5) | ||||
| 6 | (150) | 6.90 | (175.3) | +0.06 | (+1.5) |
| -0.06 | (-1.5) | ||||
| 8 | (200) | 9.05 | (229.9) | +0.06 | (+1.5) |
| -0.06 | (-1.5) | ||||
| 10 | (250) | 11.10 | (281.9) | +0.06 | (+1.5) |
| -0.06 | (-1.5) | ||||
| 12 | (300) | 13.20 | (335.3) | +0.06 | (+1.5) |
| -0.06 | (-1.5) | ||||
| 14 | (350) | 15.30 | (388.6) | +0.05 | (+1.3) |
| -0.08 | (-2.0) | ||||
| 16 | (400) | 17.40 | (442.0) | +0.05 | (+1.3) |
| -0.08 | (-2.0) | ||||
| 18 | (450) | 19.50 | (495.3) | +0.05 | (+1.3) |
| -0.08 | (-2.0) | ||||
| 20 | (500) | 21.60 | (548.6) | +0.05 | (+1.3) |
| -0.08 | (-2.0) | ||||
| 24 | (600) | 25.80 | (655.3) | +0.05 | (+1.3) |
| -0.08 | (-2.0) | ||||
| 30 | (800) | 32.00 | (812.8) | +0.08 | (+2.0) |
| -0.06 | (-1.5) | ||||
| 36 | (900) | 38.30 | (972.8) | +0.08 | (+2.0) |
| -0.06 | (-1.5) | ||||
| 42 | (1,100) | 44.50 | (1,130.3) | +0.08 | (+2.0) |
| -0.06 | (-1.5) | ||||
| 48 | (1,200) | 50.80 | (1,290.3) | +0.08 | (+2.0) |
| -0.06 | (-1.5) | ||||
| 54 | (1,400) | 57.56 | (1,462.0) | +0.08 | (+2.0) |
| -0.06 | (-1.5) | ||||
| 60 | (1,500) | 61.61 | (1,564.9) | +0.08 | (+2.0) |
| -0.06 | (-1.5) | ||||
| Nominal Size | Closest US Customary Size | External Pipe Diameter | US Equivalent† | Tolerance | |
| Upper Limit | Lower Limit | ||||
| DN mm | in. | mm | OD in. | mm | mm |
| 300 | 12 | 310 | 12.20 | +1.0 | -1.0 |
| 350 | 14 | 361 | 14.21 | +1.0 | -1.2 |
| 400 | 16 | 412 | 16.22 | +1.0 | -1.4 |
| 450 | 18 | 463 | 18.23 | +1.0 | -1.6 |
| 500 | 20 | 514 | 20.24 | +1.0 | -1.8 |
| 600 | 24 | 616 | 24.25 | +1.0 | -2.0 |
| 700 | 27 | 718 | 28.27 | +1.0 | -2.2 |
| 800 | 30 | 820 | 32.28 | +1.0 | -2.4 |
| 900 | 36 | 924 | 36.38 | +1.0 | -2.6 |
| 1,000 | 39 | 1,026 | 40.69 | +2.0 | -2.6 |
| 1,200 | 48 | 1,229 | 48.39 | +2.0 | -2.6 |
| 1,400 | 54 | 1,434 | 56.46 | +2.0 | -2.8 |
| 1,600 | 63 | 1,638 | 64.49 | +2.0 | -2.8 |
| 1,800 | 72 | 1,842 | 72.52 | +2.0 | -3.0 |
| 2,000 | 78 | 2,046 | 80.55 | +2.0 | -3.0 |
| 2,200 | 84 | 2,250 | 88.58 | +2.0 | -3.2 |
| 2,400 | 96 | 2,453 | 96.57 | +2.0 | -3.4 |
| 2,600 | 102 | 2,658 | 104.65 | +2.0 | -3.6 |
| 2,800 | 108 | 2,861 | 112.64 | +2.0 | -3.8 |
| 3,000 | 120 | 3,066 | 120.71 | +2.0 | -4.0 |
| 3,200 | 126 | 3,270 | 128.74 | +2.0 | -4.2 |
| 3,400 | 132 | 3,474 | 136.77 | +2.0 | -4.4 |
| 3,600 | 144 | 3,678 | 144.80 | +2.0 | -4.6 |
| 3,800 | 150 | 3,882 | 152.83 | +2.0 | -4.8 |
| 4,000 | 156 | 4,086 | 160.87 | +2.0 | -5.0 |
| Nominal Size | Closest US Customary Size | External Diameter | US Equivalent† | Tolerance (mm) | |
| DN mm | in. | mm | OD in. | Upper Limit | Lower Limit |
| 100 | 4 | 115.0 | 4.53 | +1.0 | +0.3 |
| 125 | 5 | 141.0 | 5.55 | +1.0 | +0.2 |
| 150 | 6 | 167.0 | 6.57 | +1.0 | +0.1 |
| 200 | 8 | 220.0 | 8.66 | +1.0 | -0.0 |
| 250 | 10 | 271.8 | 10.70 | +1.0 | -0.2 |
| 300 | 12 | 323.8 | 12.75 | +1.0 | -0.3 |
| 350 | 14 | 375.7 | 14.79 | +1.0 | -0.3 |
| 400 | 16 | 426.6 | 16.80 | +1.0 | -0.3 |
| 450 | 18 | 477.6 | 18.80 | +1.0 | -0.4 |
| 500 | 20 | 529.5 | 20.85 | +1.0 | -0.4 |
| 600 | 24 | 632.5 | 24.90 | +1.0 | -0.5 |
Note: Common practice in the industry provides for laying lengths of 10, 20, 30, 40, or 60 ft (3, 6, 9, 12, and 18 m).
4.5.3 Wall thickness. The average wall thickness of the pipe shall not be less than the nominal wall thickness published in the manufacturer’s literature current at the time of purchase, and the minimum wall thickness at any point shall not be less than 87.5 percent of that nominal wall thickness when measured in accordance with ASTM D3567.
Sec. 4.6 Pressure Classes
The standard pressure classes for pipe shall be 50, 100, 150, 200, 250, 300, 350, 400, and 450 psig (345, 689, 1,034, 1,379, 1,724, 2,069, 2,414, 2,759, and 3,103 kPa). The pressure classes refer to the maximum sustained working pressure. They are determined in accordance with Sec. 4.6.2 using a design factor of 1.8. The pressure classes may have to be changed for pipes conveying water at
elevated temperatures (in accordance with the manufacturer’s recommendations) and whenever there is a need to provide more allowance for surge pressure. For pipe subjected to circumferential bending, the effect of this bending on the hydrostatic design pressure class of the pipe must be considered.
4.6.1 Thermoplastic lined pipe. The pressure classes for thermoplastic lined pipe are based on a water temperature of 73.4°F (23°C). The classes may need to be reduced for use at temperatures greater than 73.4°F (23°C). The temperaturederating service factors shall be supplied by the pipe manufacturer.
4.6.2 Long-term hydrostatic-design pressure. The pressure classes shall be based on long-term hydrostatic-design pressure data extrapolated to 50 years, using procedure B of ASTM D2992 or, alternately, with the procedure specified in Annex A.1 of ASTM D3517. Procedure A data from ASTM D2992 may be used in place of procedure B data. End fixtures used during testing shall be representative of the product use as follows:
| Service | Test End Fixture |
| Restrained joints | Free ends |
| Unrestrained joints | Fixed ends |
Sec. 4.7 Stiffness Classes
The standard stiffness classes shall be 9, 18, 36, and 72 psi (62, 124, 248, and 496 kPa) and shall be determined in accordance with Sec. 5.1.2.2.
Sec. 4.8 Long-Term Ring-Bending Strain
4.8.1 Long-term ring-bending strain, Sb . Long-term ring-bending strain can be determined with creep-failure tests instrumented to detect an abrupt, significant reduction in mechanical properties. The test data should be statistically extrapolated to establish strength at 50 years. The value for Sb may be determined by testing per ASTM D5365, using a water test solution with a pH between 5 and 9. If these test results are not available, the value for Sb may be taken as the results of either of the following testing methods:
1. In accordance with ASTM D3681, using 1N H2SO4
2. Using results of ASTM D2992, procedure B, extrapolated to 50 years.
Sec. 4.9 Joint Types and Requirements
The pipe shall have a joining system that shall not leak for the intended service condition. A particular type of joint may be restrained or unrestrained and flexible or rigid depending on the specific joint configuration and design conditions.
4.9.1 Unrestrained. Pipe joints capable of withstanding internal pressure but not longitudinal tensile loads.
4.9.1.1 Coupling or bell-and-spigot joints. Joints with a groove either on the spigot or in the bell to retain an elastomeric gasket that shall be the sole element of the joint to provide watertightness.
4.9.1.2 Mechanical couplings joint with elastomeric seals.
4.9.1.3 Butt joint with laminated overlay.
4.9.1.4 Flanged joint. Both integral and loose ring.
4.9.2 Restrained. Pipe joints capable of withstanding internal pressure and longitudinal tensile loads.
4.9.2.1 Joints similar to the joints in Sec. 4.9.1.1 but with supplemental restraining elements.
4.9.2.2 Butt joint with laminated overlay.
4.9.2.3 Bell-and-spigot joint with laminated overlay.
4.9.2.4 Bell-and-spigot adhesive bonded joint: Three types of adhesivebonded joints are permitted by this standard. The permissible adhesive-bonded joints are as follows:
1. Tapered bell and spigot: An adhesive joint that is manufactured with a tapered socket for use in conjunction with a tapered spigot section and a suitable adhesive.
2. Straight bell and spigot: An adhesive joint that is manufactured with an untapered socket for use in conjunction with an untapered spigot and a suitable adhesive.
3. Tapered bell and straight spigot: An adhesive joint that is manufactured with a tapered socket for use in conjunction with an untapered spigot and a suitable adhesive.
4.9.2.5 Flanged. Both integral and loose ring.
4.9.2.6 Mechanical. An elastomeric sealed coupling with supplemental restraining elements.
4.9.3 Performance requirements.
4.9.3.1 Joint tightness. All joints shall meet the Laboratory Performance Requirements of Section 7 of ASTM D4161. Unrestrained joints shall be tested with a fixed-end closure condition and restrained joints shall be tested with a freeend closure condition. Rigid joints shall be exempt from angular deflection requirements of ASTM D4161. Rigid joints typically include butt joints with laminated overlay, flanged, and bell-and-spigot adhesive bonded.
4.9.3.2 Gaskets. Elastomeric gaskets shall conform to the requirements of ASTM F477.
Note: Restrained joints may increase service loads on the pipe to be greater than those experienced with unrestrained joints. The purchaser is cautioned to consider all conditions that may be encountered in the anticipated service and to consult with the manufacturer regarding the suitability of a particular type and class of pipe for service with restrained joint systems.
SECTION 5: Verification
Sec. 5.1 Inspection and Testing
5.1.1 Plant inspection by purchaser. Plant inspection by the purchaser or the omission of this inspection shall not relieve the manufacturer of the respon-©sibility to provide products that comply with the applicable requirements of this standard and of the purchaser.
5.1.1.1 Production notice. When plant inspection is specified by the purchaser, the manufacturer shall provide the purchaser with adequate advance notice of when and where the production of ordered products will commence.
5.1.1.2 Inspection limitations. If a manufacturer desires to exclude inspection of proprietary manufacturing processes, the manufacturer shall so advise the purchaser.
5.1.1.3 Plant access. The purchaser’s agent shall have free access to those parts of a manufacturer’s plant that are necessary to ensure products comply with all requirements of this standard and of the purchaser. Access may be limited to areas of the manufacturer’s plant not specifically excluded by the terms of Sec. 5.1.1.2.
5.1.1.4 Inspection aids. The manufacturer shall make available to the purchaser’s agent, without charge, the tools and assistance necessary for inspection and handling of materials.
5.1.2 Quality control tests and records. The manufacturer shall take adequate measures in the production of products to ensure compliance with the requirements of this standard. To ensure compliance, the following tests shall be performed at the indicated intervals, unless otherwise specified by the purchaser. A manufacturing run shall be defined in the manufacturer’s quality plan with a maximum six months’ production interruption. The manufacturer shall maintain
a record of all quality control tests for a period of not less than two years and, if requested, shall submit the data to the purchaser.
5.1.2.1 Hydrostatic leak tests. Unless otherwise agreed on by the purchaser and supplier, the manufacturer shall perform hydrostatic leak tests to all pipe sizes 1 in. through 96 in. (25 mm through 2,400 mm). For sizes greater than 96 in. (2,400 mm), the frequency of hydrostatic leak tests shall be as agreed on by the manufacturer and purchaser. The pipe shall not fail, leak, or weep when tested at ambient temperatures according to Sec. 5.1.2.1.1.
5.1.2.1.1 A length of pipe, when tested, shall be placed in a hydrostaticpressure test machine that seals the ends of the pipe. The pipe shall be filled with water, expelling all air, and an internal water pressure shall be applied at a uniform rate until a pressure of two (for pipe diameters up to and including 54 in.) and one and a half (for pipe diameters greater than 54 in. up to and including 96 in.) times the pressure class is reached (see Table 7). This test pressure shall be maintained for at least 30 sec. Further pumping of water to maintain the pressure is allowed during the 30-sec hold period. The pipe shall show no visual signs of weeping or leakage. Integral bells, including reinforcement sleeves, if any, or affixed couplings, shall be tested with the pipe.
5.1.2.2 Stiffness tests. The manufacturer shall perform stiffness tests at a frequency of one test for each 100 lengths of pipe produced or from each manufacturing run, whichever provides the most frequent sampling of each class and
| Pressure Class | Hydrostatic Test Pressure | ||||
| Pipe Diameters up to and Including 54 in. | Pipe Diameters Greater Than 54 in. up to and Including 96 in. | ||||
| psi | kPa | psi | kPa | psi | kPa |
| 50 | 345 | 100 | 689 | 75 | |
| 100 | 689 | 200 | 1,379 | 150 | 1,034 |
| 150 | 1,034 | 300 | 2,068 | 225 | 1,551 |
| 200 | 1,379 | 400 | 2,758 | 300 | 2,069 |
| 250 | 1,724 | 500 | 3,447 | 375 | 2,586 |
| 300 | 2,069 | 600 | 4,138 | 450 | 3,103 |
| 350 | 2,414 | 700 | 4,828 | 525 | 3,620 |
| 400 | 2,750 | 800 | 5,518 | 600 | 4,137 |
| 450 | 3,103 | 900 | 6,206 | 675 | 4,654 |
| Nominal Pipe Size | Stiffness Class—psi (kPa) | ||||
| 9 (62) | 18 (124) | 36 (248) | 72 (496) | ||
| in. | (mm) | Minimum Pipe Stiffness Required—psi (kPa) | |||
| 1-8 | (25-200) | NR* | NR | 36.0 (248) | 72.0 (496) |
| 10 | (250) | NR | 18.0 (124) | 36.0 (248) | 72.0 (496) |
| 12-144 | (300-3,600) | 9.0 (62) | 18.0 (124) | 36.0 (248) | 72.0 (496) |
| Stiffness Class—psi (kPa) | ||||
| 9 (62) | 18 (124) | 36 (248) | 72 (496) | |
| Deflection Level | Ring Deflection—% of Diameter | |||
| A | 18 | 15 | 12 | 9 |
| B | 30 | 25 | 20 | 15 |
size. The minimum pipe stiffness (F/ΔY) shall be determined at 5 percent deflection using the apparatus and procedure of ASTM D2412, with three exceptions. The exceptions are (1) the wall thickness shall be measured to the nearest 0.01 in. (0.25 mm); (2) the specimen taken from the pipe barrel shall be loaded to 5 percent deflection, the load shall be recorded, and the loading continued to level A deflection (Table 9) and then to level B deflection; and (3) test frequency shall be as specified in this paragraph.
5.1.2.2.1 The pipe shall exhibit, without structural damage, the minimum stiffness specified in Table 8 when tested in accordance with Sec. 5.1.2.2.
5.1.2.2.2 At deflection level A (Table 9), there shall be no interior surface cracks or crazes. At deflection level B (Table 9), there shall be no structural damage as evidenced by interlaminar separation, separation of the liner or surface layer (if incorporated) from the structural wall, tensile failure of the glass-fiber reinforcement, and fracture or buckling of the pipe wall. Both level A and level B criteria must be met. The pipe stiffness test specimen may be used for these tests.
Note: This is a visual observation for quality control purposes only and should not be considered a simulated service test. Table 9 values are based on an in-use, long-term deflection limit of 5 percent and provide an appropriate uniform safety margin for all pipe stiffnesses.
1. For other pipe stiffness levels, appropriate values for level A and level B deflections (Table 9) may be computed as follows:
Level A at new pipe stiffness (PS) = 9 × (72/new PS) 0 .33
Level B at new pipe stiffness (PS) = new Level A / 0.6
2. Because products may have limits of other than 5 percent long-term deflection, level A and level B deflections (Table 9) may be proportionally adjusted to maintain equivalent in-use safety margins. For example, a 4 percent long-term limiting deflection would result in a 20 percent reduction of level A and level B deflections, while a 6 percent limiting deflection would result in a 20 percent increase in level A and level B deflection values.
5.1.2.3 Hoop tensile strength tests. The manufacturer shall perform hoop tensile strength tests at a frequency of one test for each 100 lengths of pipe produced or from each manufacturing run, whichever provides the most frequent sampling of each class and size. The minimum hoop tensile strength properties shall be determined from the average of the test results of three specimens cut from the sample when using the apparatus and procedure of one of the following test methods:
1. ASTM D2290, procedure A. The specimen width shall be appropriate to the diameter and wall thickness of the pipe. Reduced-section specimens are acceptable. A test apparatus with a varying rate of motion may be used, provided that the speed of testing does not exceed 0.10 in./min (2.5 mm/min) in accordance with procedure A. Except in cases of disagreement, routine quality control tests may be performed at ambient conditions of temperature and humidity, and calculations need not include the standard deviation.
2. ASTM D638. The widths of specimens may be increased for pipe wall thicknesses greater than 0.55 in. (14 mm). Means may be provided to minimize the bending moment imposed during the test. Except in cases of disagreement, calculations from routine quality control test results need not include the standard deviation.
3. ASTM D1599.
5.1.2.3.1 The pipe shall meet or exceed the minimum short-term hoop tensile strength calculated by Eq 1 or Eq 2, whichever is greater. The minimum shortterm hoop tensile strengths calculated per Eq 2 are stated in Table 10.A and 10.B.
F = Si / Sr (Pr) (1)
F =4.0 (Pr) (2)
Where:
F = required minimum hoop tensile strength, lbf/in. (kN/m) of width
Si = initial design hoop tensile strength, psi (kPa)
Sr = hoop tensile stress at pressure class, psi (kPa)
P = specified pressure class from Table 7, psi (kPa)
= nominal pipe radius, in. [(OD— single wall thickness)/2] (m)
5.1.2.3.2 The values of Si and Sr should be established from the manufacturer’s long-term hydrostatic tests performed in accordance with Sec. 4.6.2. Si shall be taken as the 95 percent lower-confidence level, back extrapolated to 0.1 hr. This takes into consideration variations in glass-fiber strength and manufacturing methods. Sr is the calculated hoop tensile stress at the pressure class.
5.1.2.4 Axial tensile strength tests. The manufacturer shall perform axial tensile strength tests at a frequency of one test for each 100 lengths of pipe produced or from each manufacturing run, whichever provides the most frequent sampling of each class and size. The minimum axial tensile strength shall be determined from the average of the test results of three specimens cut from the sample when using the apparatus and procedure of ASTM D638, except the provisions for maximum thickness shall not apply; or ASTM D2105, depending on the size of the pipe specimens to be tested.
5.1.2.4.1 The pipe shall have a minimum axial tensile elongation to failure of 0.25 percent and meet or exceed the minimum axial tensile strength requirements listed in Table 11 when tested in accordance with ASTM D638 or ASTM D2105.
Note: The values in Table 11 are the minimum criteria and are based on buried pipe without axial thrust loads. Required axial strength for aboveground pipes subject to beam bending, or any pipes that must withstand longitudinal thrust loads or any unusual axial tensile forces, may exceed the values in Table 11.A and 11.B.
5.1.2.5 Beam-strength tests. The beam-strength test is a design-qualification test required only when there is a significant change in the design or construction of the pipe. A significant change is considered to occur when the average axial
| Nominal Diameter (in.) | Pressure Class | ||||||||
| 50 (psi) | 100 (psi) | 150 (psi) | 200 (psi) | 250 (psi) | 300 (psi) | 350 (psi) | 400 (psi) | 450 (psi) | |
| 1.0 | 100 | 200 | 300 | 400 | 500 | 600 | 700 | 800 | 900 |
| 1.5 | 150 | 300 | 450 | 600 | 750 | 900 | 1,050 | 1,200 | 1,350 |
| 2.0 | 200 | 400 | 600 | 800 | 1,000 | 1,200 | 1,400 | 1,600 | 1,800 |
| 2.5 | 250 | 500 | 750 | 1,000 | 1,250 | 1,500 | 1,750 | 2,000 | 2,250 |
| 3.0 | 300 | 600 | 900 | 1,200 | 1,500 | 1,800 | 2,100 | 2,400 | 2,700 |
| 4.0 | 400 | 800 | 1,200 | 1,600 | 2,000 | 2,400 | 2,800 | 3,200 | 3,600 |
| 6.0 | 600 | 1,200 | 1,800 | 2,400 | 3,000 | 3,600 | 4,200 | 4,800 | 5,400 |
| 8.0 | 800 | 1,600 | 2,400 | 3,200 | 4,000 | 4,800 | 5,600 | 6,400 | 7,200 |
| 10.0 | 1,000 | 2,000 | 3,000 | 4,000 | 5,000 | 6,000 | 7,000 | 8,000 | 9,000 |
| 12.0 | 1,200 | 2,400 | 3,600 | 4,800 | 6,000 | 7,200 | 8,400 | 9,600 | 10,800 |
| 14.0 | 1,400 | 2,800 | 4,200 | 5,600 | 7,000 | 8,400 | 9,800 | 11,200 | 12,600 |
| 15.0 | 1,500 | 3,000 | 4,500 | 6,000 | 7,500 | 9,000 | 10,500 | 12,000 | 13,500 |
| 16.0 | 1,600 | 3,200 | 4,800 | 6,400 | 8,000 | 9,600 | 11,200 | 12,800 | 14,400 |
| 18.0 | 1,800 | 3,600 | 5,400 | 7,200 | 9,000 | 10,800 | 12,600 | 14,400 | 16,200 |
| 20.0 | 2,000 | 4,000 | 6,000 | 8,000 | 10,000 | 12,000 | 14,000 | 16,000 | 18,000 |
| 21.0 | 2,100 | 4,200 | 6,300 | 8,400 | 10,500 | 12,600 | 14,700 | 16,800 | 18,900 |
| 24.0 | 2,400 | 4,800 | 7,200 | 9,600 | 12,000 | 14,400 | 16,800 | 19,200 | 21,600 |
| 27.0 | 2,700 | 5,400 | 8,100 | 10,800 | 13,500 | 16,200 | 18,900 | 21,600 | 24,300 |
| 30.0 | 3,000 | 6,000 | 9,000 | 12,000 | 15,000 | 18,000 | 21,000 | 24,000 | 27,000 |
| 33.0 | 3,300 | 6,600 | 9,900 | 13,200 | 16,500 | 19,800 | 23,100 | 26,400 | 29,700 |
| 36.0 | 3,600 | 7,200 | 10,800 | 14,400 | 18,000 | 21,600 | 25,200 | 28,800 | 32,400 |
| 39.0 | 3,900 | 7,800 | 11,700 | 15,600 | 19,500 | 23,400 | 27,300 | 31,200 | 35,100 |
| 42.0 | 4,200 | 8,400 | 12,600 | 16,800 | 21,000 | 25,200 | 29,400 | 33,600 | 37,800 |
| 45.0 | 4,500 | 9,000 | 13,500 | 18,000 | 22,500 | 27,000 | 31,500 | 36,000 | 40,500 |
| 48.0 | 4,800 | 9,600 | 14,400 | 19,200 | 24,000 | 28,800 | 33,600 | 38,400 | 43,200 |
| 51.0 | 5,100 | 10,200 | 15,300 | 20,400 | 25,500 | 30,600 | 35,700 | 40,800 | 45,900 |
| 54.0 | 5,400 | 10,800 | 16,200 | 21,600 | 27,000 | 32,400 | 37,800 | 43,200 | 48,600 |
| 60.0 | 6,000 | 12,000 | 18,000 | 24,000 | 30,000 | 36,000 | 42,000 | 48,000 | 54,000 |
| 66.0 | 6,600 | 13,200 | 19,800 | 26,400 | 33,000 | 39,600 | 46,200 | 52,800 | 59,400 |
| 72.0 | 7,200 | 14,400 | 21,600 | 28,800 | 36,000 | 43,200 | 50,400 | 57,600 | 64,800 |
| 78.0 | 7,800 | 15,600 | 23,400 | 31,200 | 39,000 | 46,800 | 54,600 | 62,400 | 70,200 |
| 84.0 | 8,400 | 16,800 | 25,200 | 33,600 | 42,000 | 50,400 | 58,800 | 67,200 | 75,600 |
| 90.0 | 9,000 | 18,000 | 27,000 | 36,000 | 45,000 | 54,000 | 63,000 | 72,000 | 81,000 |
| 96.0 | 9,600 | 19,200 | 28,800 | 38,400 | 48,000 | 57,600 | 67,200 | 76,800 | 86,400 |
| 102.0 | 10,200 | 20,400 | 30,600 | 40,800 | 51,000 | 61,200 | 71,400 | 81,600 | 91,800 |
| 108.0 | 10,800 | 21,600 | 32,400 | 43,200 | 54,000 | 64,800 | 75,600 | 86,400 | 97,200 |
| 114.0 | 11,400 | 22,800 | 34,200 | 45,600 | 57,000 | 68,400 | 79,800 | 91,200 | 102,600 |
| 120.0 | 12,000 | 24,000 | 36,000 | 48,000 | 60,000 | 72,000 | 84,000 | 96,000 | 108,000 |
| 132.0 | 13,200 | 26,400 | 39,600 | 52,800 | 66,000 | 79,200 | 92,400 | 105,600 | 118,800 |
| 144.0 | 14,400 | 28,800 | 43,200 | 57,600 | 72,000 | 86,400 | 100,800 | 115,200 | 129,600 |
| 156.0 | 15,600 | 31,200 | 46,800 | 62,400 | 78,000 | 93,600 | 109,200 | 124,800 | 140,400 |
| Nominal Diameter (mm) | Pressure Class kPa | ||||||||
| 245 (kPa) | 689 (kPa) | 1,034 (kPa) | 1,379 (kPa) | 1,724 (kPa) | 2,069 (kPa) | 2,414 (kPa) | 2,759 (kPa) | 3,103 (kPa) | |
| 25 | 17 | 34 | 52 | 69 | 86 | 103 | 121 | 138 | 155 |
| 40 | 28 | 55 | 83 | 110 | 138 | 166 | 193 | 221 | 248 |
| 50 | 35 | 69 | 103 | 138 | 172 | 207 | 241 | 276 | 310 |
| 65 | 45 | 90 | 134 | 179 | 224 | 269 | 314 | 359 | 403 |
| 80 | 55 | 110 | 165 | 221 | 276 | 331 | 386 | 441 | 496 |
| 100 | 69 | 138 | 207 | 276 | 345 | 414 | 483 | 552 | 621 |
| 150 | 104 | 207 | 310 | 414 | 517 | 621 | 724 | 828 | 931 |
| 200 | 138 | 276 | 414 | 552 | 690 | 828 | 966 | 1,104 | 1,241 |
| 250 | 173 | 345 | 517 | 690 | 862 | 1,035 | 1,207 | 1,380 | 1,552 |
| 300 | 207 | 413 | 620 | 827 | 1,034 | 1,241 | 1,448 | 1,655 | 1,862 |
| 350 | 242 | 482 | 724 | 965 | 1,207 | 1,448 | 1,690 | 1,931 | 2,172 |
| 375 | 259 | 517 | 776 | 1,034 | 1,293 | 1,552 | 1,811 | 2,069 | 2,327 |
| 400 | 276 | 551 | 827 | 1,103 | 1,379 | 1,655 | 1,931 | 2,207 | 2,482 |
| 450 | 311 | 620 | 931 | 1,241 | 1,552 | 1,862 | 2,173 | 2,483 | 2,793 |
| 500 | 345 | 689 | 1,034 | 1,379 | 1,724 | 2,069 | 2,414 | 2,759 | 3,103 |
| 550 | 380 | 758 | 1,137 | 1,517 | 1,896 | 2,276 | 2,655 | 3,035 | 3,413 |
| 600 | 414 | 827 | 1,241 | 1,655 | 2,069 | 2,483 | 2,897 | 3,311 | 3,724 |
| 700 | 483 | 965 | 1,448 | 1,931 | 2,414 | 2,897 | 3,380 | 3,863 | 4,344 |
| 750 | 518 | 1,034 | 1,551 | 2,069 | 2,586 | 3,104 | 3,621 | 4,139 | 4,655 |
| 850 | 587 | 1,171 | 1,758 | 2,344 | 2,931 | 3,517 | 4,104 | 4,690 | 5,275 |
| 900 | 621 | 1,240 | 1,861 | 2,482 | 3,103 | 3,724 | 4,345 | 4,966 | 5,585 |
| 1,000 | 690 | 1,378 | 2,068 | 2,758 | 3,448 | 4,138 | 4,828 | 5,518 | 6,206 |
| 1,100 | 759 | 1,516 | 2,275 | 3,034 | 3,793 | 4,552 | 5,311 | 6,070 | 6,827 |
| 1,150 | 794 | 1,585 | 2,378 | 3,172 | 3,965 | 4,759 | 5,552 | 6,346 | 7,137 |
| 1,200 | 828 | 1,654 | 2,482 | 3,310 | 4,138 | 4,966 | 5,794 | 6,622 | 7,447 |
| 1,300 | 897 | 1,791 | 2,688 | 3,585 | 4,482 | 5,379 | 6,276 | 7,173 | 8,068 |
| 1,400 | 966 | 1,929 | 2,895 | 3,861 | 4,827 | 5,793 | 6,759 | 7,725 | 8,688 |
| 1,500 | 1,035 | 2,067 | 3,102 | 4,137 | 5,172 | 6,207 | 7,242 | 8,277 | 9,309 |
| 1,700 | 1,173 | 2,343 | 3,516 | 4,689 | 5,862 | 7,035 | 8,208 | 9,381 | 10,550 |
| 1,800 | 1,242 | 2,480 | 3,722 | 4,964 | 6,206 | 7,448 | 8,690 | 9,932 | 11,171 |
| 2,000 | 1,380 | 2,756 | 4,136 | 5,516 | 6,896 | 8,276 | 9,656 | 11,036 | 12,412 |
| 2,200 | 1,518 | 3,032 | 4,550 | 6,068 | 7,586 | 9,104 | 10,622 | 12,140 | 13,653 |
| 2,300 | 1,587 | 3,169 | 4,756 | 6,343 | 7,930 | 9,517 | 11,104 | 12,691 | 14,274 |
| 2,400 | 1,656 | 3,307 | 4,963 | 6,619 | 8,275 | 9,931 | 11,587 | 13,243 | 14,894 |
| 2,600 | 1,794 | 3,583 | 5,377 | 7,171 | 8,965 | 10,759 | 12,553 | 14,347 | 16,136 |
| 2,800 | 1,932 | 3,858 | 5,790 | 7,722 | 9,654 | 11,586 | 13,518 | 15,450 | 17,377 |
| 2,900 | 2,001 | 3,996 | 5,997 | 7,998 | 9,999 | 12,000 | 14,001 | 16,002 | 17,997 |
| 3,000 | 2,070 | 4,134 | 6,204 | 8,274 | 10,344 | 12,414 | 14,484 | 16,554 | 18,618 |
| 3,400 | 2,346 | 4,685 | 7,031 | 9,377 | 11,723 | 14,069 | 16,415 | 18,761 | 21,100 |
| 3,600 | 2,484 | 4,961 | 7,445 | 9,929 | 12,413 | 14,897 | 17,381 | 19,865 | 22,342 |
| 4,000 | 2,760 | 5,512 | 8,272 | 11,032 | 13,792 | 16,552 | 19,312 | 22,072 | 24,824 |
| Nominal Diameter (in.) | Pressure Class | ||||||||
| 50 (psi) | 100 (psi) | 150 (psi) | 200 (psi) | 250 (psi) | 300 (psi) | 350 (psi) | 400 (psi) | 450 (psi) | |
| 1.0 | 360 | 360 | 360 | 360 | 360 | 360 | 360 | 360 | 360 |
| 1.5 | 360 | 360 | 360 | 360 | 360 | 360 | 360 | 360 | 360 |
| 2.0 | 360 | 360 | 360 | 360 | 360 | 360 | 360 | 360 | 360 |
| 2.5 | 360 | 360 | 360 | 360 | 360 | 360 | 360 | 360 | 360 |
| 3.0 | 360 | 360 | 360 | 360 | 360 | 360 | 360 | 360 | 360 |
| 4.0 | 360 | 360 | 360 | 360 | 360 | 360 | 364 | 400 | 450 |
| 6.0 | 360 | 360 | 360 | 360 | 405 | 468 | 525 | 600 | 675 |
| 8.0 | 580 | 580 | 580 | 580 | 580 | 624 | 700 | 800 | 900 |
| 10.0 | 580 | 580 | 580 | 580 | 650 | 780 | 875 | 1,000 | 1,125 |
| 12.0 | 580 | 580 | 580 | 624 | 780 | 936 | 1,050 | 1,200 | 1,350 |
| 14.0 | 580 | 580 | 609 | 728 | 910 | 1,092 | 1,225 | 1,400 | 1,575 |
| 15.0 | 580 | 580 | 653 | 780 | 975 | 1,170 | 1,313 | 1,500 | 1,688 |
| 16.0 | 580 | 580 | 696 | 832 | 1,040 | 1,248 | 1,400 | 1,600 | 1,800 |
| 18.0 | 580 | 580 | 783 | 936 | 1,170 | 1,404 | 1,575 | 1,800 | 2,025 |
| 20.0 | 580 | 580 | 870 | 1,040 | 1,300 | 1,560 | 1,750 | 2,000 | 2,250 |
| 21.0 | 580 | 609 | 914 | 1,092 | 1,365 | 1,638 | 1,838 | 2,100 | 2,363 |
| 24.0 | 580 | 696 | 1,044 | 1,248 | 1,560 | 1,800 | 2,100 | 2,400 | 2,700 |
| 27.0 | 580 | 783 | 1,175 | 1,404 | 1,688 | 2,025 | 2,363 | 2,700 | 3,038 |
| 30.0 | 580 | 870 | 1,305 | 1,560 | 1,875 | 2,250 | 2,625 | 3,000 | 3,375 |
| 33.0 | 627 | 957 | 1,436 | 1,716 | 2,063 | 2,475 | 2,888 | 3,300 | 3,713 |
| 36.0 | 684 | 1,044 | 1,566 | 1,800 | 2,250 | 2,700 | 3,150 | 3,600 | 4,050 |
| 39.0 | 741 | 1,131 | 1,697 | 1,872 | 2,340 | 2,808 | 3,276 | 3,744 | 4,212 |
| 42.0 | 798 | 1,218 | 1,827 | 2,016 | 2,520 | 3,024 | 3,528 | 4,032 | 4,536 |
| 45.0 | 855 | 1,305 | 1,958 | 2,160 | 2,700 | 3,240 | 3,780 | 4,320 | 4,860 |
| 48.0 | 912 | 1,392 | 2,088 | 2,304 | 2,880 | 3,456 | 4,032 | 4,608 | 5,184 |
| 51.0 | 969 | 1,479 | 2,219 | 2,448 | 3,060 | 3,672 | 4,284 | 4,896 | 5,508 |
| 54.0 | 1,026 | 1,566 | 2,349 | 2,592 | 3,240 | 3,726 | 4,347 | 4,968 | 5,589 |
| 60.0 | 1,140 | 1,740 | 2,520 | 2,880 | 3,600 | 4,140 | 4,830 | 5,520 | 6,210 |
| 66.0 | 1,254 | 1,914 | 2,673 | 3,036 | 3,795 | 4,554 | 5,313 | 5,808 | 6,534 |
| 72.0 | 1,368 | 2,088 | 2,916 | 3,312 | 4,140 | 4,968 | 5,796 | 6,336 | 7,128 |
| 78.0 | 1,482 | 2,106 | 3,159 | 3,432 | 4,290 | 5,148 | 6,006 | 6,864 | 7,722 |
| 84.0 | 1,596 | 2,268 | 3,402 | 3,696 | 4,620 | 5,292 | 6,174 | 7,056 | 7,938 |
| 90.0 | 1,710 | 2,430 | 3,645 | 3,960 | 4,950 | 5,670 | 6,615 | 7,380 | 8,303 |
| 96.0 | 1,824 | 2,592 | 3,888 | 4,224 | 5,280 | 6,048 | 7,056 | 7,680 | 8,640 |
| 102.0 | 1,938 | 2,754 | 4,131 | 4,488 | 5,610 | 6,426 | 7,497 | 8,160 | 9,180 |
| 108.0 | 2,052 | 2,916 | 4,374 | 4,752 | 5,940 | 6,804 | 7,938 | 8,640 | 9,720 |
| 114.0 | 2,166 | 3,078 | 4,617 | 5,016 | 6,270 | 7,182 | 8,379 | 9,120 | 10,260 |
| 120.0 | 2,280 | 3,240 | 4,860 | 5,280 | 6,600 | 7,560 | 8,820 | 9,600 | 10,800 |
| 132.0 | 2,508 | 3,564 | 5,346 | 5,808 | 7,260 | 8,316 | 9,702 | 10,560 | 11,880 |
| 144.0 | 2,736 | 3,888 | 5,832 | 6,336 | 7,920 | 9,072 | 10,584 | 11,520 | 12,960 |
| 156.0 | 2,964 | 4,212 | 6,318 | 6,864 | 8,580 | 9,828 | 11,466 | 12,480 | 14,040 |
| Nominal Diameter (mm) | Pressure Class | ||||||||
| 345 (kPa) | 689 (kPa) | 1,034 (kPa) | 1,379 (kPa) | 1,724 (kPa) | 2,069 (kPa) | 2,414 (kPa) | 2,759 (kPa) | 3,103 (kPa) | |
| 25 | 63 | 63 | 63 | 63 | 63 | 63 | 63 | 63 | 63 |
| 40 | 63 | 63 | 63 | 63 | 63 | 63 | 63 | 63 | 63 |
| 50 | 63 | 63 | 63 | 63 | 63 | 63 | 63 | 63 | 63 |
| 65 | 63 | 63 | 63 | 63 | 63 | 63 | 63 | 63 | 63 |
| 80 | 63 | 63 | 63 | 63 | 63 | 63 | 63 | 63 | 63 |
| 100 | 63 | 63 | 63 | 63 | 63 | 63 | 64 | 70 | 79 |
| 150 | 63 | 63 | 63 | 63 | 71 | 82 | 92 | 105 | 118 |
| 200 | 102 | 102 | 102 | 102 | 102 | 109 | 123 | 140 | 158 |
| 250 | 102 | 102 | 102 | 102 | 114 | 137 | 153 | 175 | 197 |
| 300 | 102 | 102 | 102 | 109 | 137 | 164 | 184 | 210 | 236 |
| 350 | 102 | 102 | 107 | 127 | 159 | 191 | 215 | 245 | 276 |
| 375 | 102 | 102 | 114 | 137 | 171 | 205 | 230 | 263 | 296 |
| 400 | 102 | 102 | 122 | 146 | 182 | 219 | 245 | 280 | 315 |
| 450 | 102 | 102 | 137 | 164 | 205 | 246 | 276 | 315 | 355 |
| 500 | 102 | 102 | 152 | 182 | 228 | 273 | 306 | 350 | 394 |
| 550 | 102 | 107 | 160 | 191 | 239 | 287 | 322 | 368 | 414 |
| 600 | 102 | 122 | 183 | 219 | 273 | 315 | 368 | 420 | 473 |
| 700 | 102 | 137 | 206 | 246 | 296 | 355 | 414 | 473 | 532 |
| 750 | 102 | 152 | 229 | 273 | 328 | 394 | 460 | 525 | 591 |
| 850 | 110 | 168 | 251 | 301 | 361 | 433 | 506 | 578 | 650 |
| 900 | 120 | 183 | 274 | 315 | 394 | 473 | 552 | 630 | 709 |
| 1,000 | 130 | 198 | 297 | 328 | 410 | 492 | 574 | 656 | 738 |
| 1,100 | 140 | 213 | 320 | 353 | 441 | 530 | 618 | 706 | 794 |
| 1,150 | 150 | 229 | 343 | 378 | 473 | 567 | 662 | 757 | 851 |
| 1,200 | 160 | 244 | 366 | 403 | 504 | 605 | 706 | 807 | 908 |
| 1,300 | 170 | 259 | 388 | 429 | 536 | 643 | 750 | 857 | 965 |
| 1,400 | 180 | 274 | 411 | 454 | 567 | 652 | 761 | 870 | 979 |
| 1,500 | 200 | 305 | 441 | 504 | 630 | 725 | 846 | 967 | 1,087 |
| 1,700 | 220 | 335 | 468 | 532 | 665 | 797 | 930 | 1,017 | 1,144 |
| 1,800 | 240 | 366 | 511 | 580 | 725 | 870 | 1,015 | 1,110 | 1,248 |
| 2,000 | 260 | 369 | 553 | 601 | 751 | 902 | 1,052 | 1,202 | 1,352 |
| 2,200 | 279 | 397 | 596 | 647 | 809 | 927 | 1,081 | 1,236 | 1,390 |
| 2,300 | 299 | 426 | 638 | 693 | 867 | 993 | 1,158 | 1,292 | 1,454 |
| 2,400 | 319 | 454 | 681 | 740 | 925 | 1,059 | 1,236 | 1,345 | 1,513 |
| 2,600 | 339 | 482 | 723 | 786 | 982 | 1,125 | 1,313 | 1,429 | 1,608 |
| 2,800 | 359 | 511 | 766 | 832 | 1,040 | 1,192 | 1,390 | 1,513 | 1,702 |
| 2,900 | 379 | 539 | 809 | 878 | 1,098 | 1,258 | 1,467 | 1,597 | 1,797 |
| 3,000 | 399 | 567 | 851 | 925 | 1,156 | 1,324 | 1,545 | 1,681 | 1,891 |
| 3,400 | 439 | 624 | 936 | 1,017 | 1,271 | 1,456 | 1,699 | 1,849 | 2,080 |
| 3,600 | 479 | 681 | 1,021 | 1,110 | 1,387 | 1,589 | 1,853 | 2,017 | 2,270 |
| 4,000 | 519 | 738 | 1,106 | 1,202 | 1,503 | 1,721 | 2,008 | 2,185 | 2,459 |
| Nominal Pipe Size | Beam Load P | ||
| in. | (mm)* | lbf | kN |
| 1 | (25) | 10 | (0.04) |
| 11⁄2 | (40) | 25 | (0.11) |
| 2 | (50) | 45 | (0.20) |
| 21⁄2 | (65) | 75 | (0.33) |
| 3 | (80) | 100 | (0.44) |
| 4 | (100) | 185 | (0.82) |
| 6 | (150) | 425 | (1.90) |
| 8 | (200) | 800 | (3.60) |
| 10 | (250) | 1,200 | (5.30) |
| 12 | (300) | 1,600 | (7.10) |
| 14 | (350) | 2,200 | (9.80) |
| 15 | (375) | 2,600 | (11.60) |
| 16 | (400) | 3,000 | (13.30) |
| 18 | (450) | 4,000 | (17.80) |
| 20 | (500) | 4,400 | (19.60) |
| 21 | (550) | 5,000 | (22.20) |
| 24 | (600) | 6,400 | (28.50) |
| 27 | (700) | 8,000 | (35.60) |
tensile strength as determined in Sec. 5.1.2.4 decreases more than 15 percent. Two methods can be used.
Method 1: Method 1 can be used for pipe sizes up to and including 27 in. (700 mm). In method 1, the pipe shall withstand, without failure, the beam loads listed in Table 12 when tested in accordance with the beam-strength test method of ASTM D3517.
Method 2: Method 2 can be used for all pipe sizes. In method 2, the pipe shall meet or exceed (1) the minimum axial tensile strength listed in Table 11 when tested in accordance with Sec. 5.1.2.4; and (2) the minimum axial compressive strength listed in Table 13 when tested in accordance with ASTM D695.
5.1.2.6 Dimensions. The manufacturer shall inspect one length per 100 lengths of pipe before shipment for dimensions and tolerances outlined in Sec. 4.5.
| Nominal Pipe Size | Minimum Axial Compressive Strength | ||
| in. | (mm)* | lbfln. of circumference | (kN/m of circumference) |
| 1-6 | (25-150) | 360 | (63) |
| 8-30 | (200-800) | 580 | (102) |
| 33 | (850) | 640 | (111) |
| 36 | (900) | 700 | (122) |
| 39 | (1,000) | 780 | (137) |
| 42 | (1,100) | 800 | (140) |
| 45 | (1,150) | 860 | (150) |
| 48 | (1,200) | 920 | (161) |
| 51 | (1,300) | 980 | (171) |
| 54 | (1,400) | 1,040 | (182) |
| 60 | (1,500) | 1,140 | (200) |
| 66 | (1,700) | 1,260 | (220) |
| 72 | (1,800) | 1,360 | (238) |
| 78 | (2,000) | 1,480 | (260) |
| 84 | (2,200) | 1,600 | (280) |
| 90 | (2,300) | 1,720 | (301) |
| 96 | (2,400) | 1,840 | (322) |
| 102 | (2,600) | 1,940 | (340) |
| 108 | (2,800) | 2,060 | (360) |
| 114 | (2,900) | 2,180 | (382) |
| 120 | (3,000) | 2,280 | (400) |
| 132 | (3,400) | 2,520 | (440) |
| 144 | (3,600) | 2,740 | (480) |
| 156 | (4,000) | 2,964 | (520) |
Sec. 5.2 Rejection and Retesting
If the results of a test do not conform to the requirements of this standard, that test may be repeated on two additional samples from the same lot of pipe. Each of the two samples shall conform to the requirements specified. If either of the two additional samples fail, the lot may be rejected, at the option of the purchaser. Rejection should be reported to the manufacturer or supplier promptly and in writing.
SECTION 6: Delivery
Sec. 6.1 Marking
Each standard length and random length shall be clearly marked. Marking shall be applied without indentation so as to remain legible during normal handling and installation practices. At a minimum, these markings shall consist of the following: (1) the phrase ANSI/AWWA C950; (2) nominal pipe size, cell classification, and diameter series; (3) AWWA pressure class; (4) stiffness class; and (5) manufacturer’s mark and identity code.
Sec. 6.2 Shipping
All pipe and couplings shall, unless otherwise specified by the purchaser, be prepared for standard commercial shipment.
Sec. 6.3 Affidavit of Compliance
The manufacturer shall, if so specified by the purchaser, provide an affidavit ©that all delivered materials comply with the requirements of this standard and of the purchaser.
This page intentionally blank.
This page intentionally blank.
AWWA is the authoritative resource for knowledge, information, and advocacy to improve the quality and supply of water in North America and beyond. AWWA is the largest organization of water professionals in the world. AWWA advances public health, safety, and welfare by uniting the efforts of the full spectrum of the entire water community. Through our collective strength, we become better stewards of water for the greatest good of people and the environment.
Erratum to