1 Scope
This International Standard specifies requirements and provides recommendations for the design, manufacturing, testing and documentation of ball, check, gate and plug valves for application in pipeline systems meeting the requirements of ISO 13623 for the petroleum and natural gas industries. This International Standard is not applicable to subsea pipeline valves, as they are covered by a separate International Standard (ISO 14723).
This International Standard is not applicable to valves for pressure ratings exceeding PN 420 (Class 2 500).
2 Conformance
2.1 Units of measurement
In this International Standard, data are expressed in both SI units and USC units. For a specific order item, unless otherwise stated, only one system of units shall be used, without combining data expressed in the other system. For data expressed in SI units, a comma is used as the decimal separator and a space is used as the thousands separator. For data expressed in USC units, a dot (on the line) is used as the decimal separator and a comma is used as the thousands separator.
2.2 Rounding
Except as otherwise required by this International Standard, to determine conformance with the specified requirements, observed or calculated values shall be rounded to the nearest unit in the last right-hand place of figures used in expressing the limiting value, in accordance with the rounding method of ISO 31-0:1992, Annex B, Rule A.
2.3 Compliance to standard
A quality system should be applied to assist compliance with the requirements of this International Standard.
NOTE ISO/TS 29001 gives sector-specific guidance on quality management systems.
The manufacturer shall be responsible for complying with all of the applicable requirements of this International Standard. It shall be permissible for the purchaser to make any investigation necessary in order to be assured of compliance by the manufacturer and to reject any material that does not comply.
3 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments, corrigendum, and maintenance agency output) applies.
ISO 31-0,1992, Quantities and units — Part 0: General principles
ISO 148-1, Metallic materials — Charpy pendulum impact test — Part 1: Test method
ISO 228-1, Pipe threads where pressure-tight joints are not made on the threads — Part 1: Dimensions, tolerances and designation
ISO 5208:1993, Industrial valves — Pressure testing of valves
ISO 7268, Pipe components — Definition of nominal pressure
ISO 9606-1, Approval testing of welders — Fusion welding — Part 1: Steels
ISO 9712, Non-destructive testing — Qualification and certification of personnel
ISO 10474, Steel and steel products — Inspection documents
ISO 10497, Testing of valves — Fire type-testing requirements
ISO 15156 (all parts), Petroleum and natural gas industries — Materials for use in H2S -containing environments in oil and gas production
ISO 15607, Specification and qualification of welding procedures for metallic materials — General rules
ISO 15609 (all parts), Specification and qualification of welding procedures for metallic materials — Welding procedure specification
ISO 15614-1, Specification and qualification of welding procedures for metallic materials — Welding procedure test — Part 1: Arc and gas welding of steels and arc welding of nickel and nickel alloys
ISO 23277, Non-destructive testing of welds — Penetrant testing of welds — Acceptance levels
ISO 23278, Non-destructive testing of welds — Magnetic particle testing of welds — Acceptance levels
ASME B1.20.1
1)
, Pipe Threads, General Purpose, Inch
ASME B16.5-1996, Pipe Flanges and Flanged Fittings : NPS 1/2 through 24
ASME B16.10-2000, Face-to-Face and End-to-End Dimensions of Valves
ASME B16.34-2004, Valves, Flanged, Threaded, and Welding End
ASME B16.47-2006, Large Diameter Steel Flanges : NPS 26 Through NPS 60 Metric/Inch Standard
ASME B31.4-2006, Pipeline Transportation Systems for Liquid Hydrocarbons and Other Liquids
ASME B31.8-2003, Gas Transmission and Distribution Piping Systems
ASME Boiler and Pressure Vessel Code, Section V: Nondestructive Examination
1) American Society of Mechanical Engineers International, 345 East 47 th Street, NY 10017-2392, USA
ASME Boiler and Pressure Vessel Code — Section VIII: Rules for Construction of Pressure Vessels Division 1, Rules for Construction of Pressure Vessels
ASME Boiler and Pressure Vessel Code — Section VIII: Rules for Construction of Pressure Vessels
Division 2: Alternative Rules
ASME Boiler and Pressure Vessel Code — Section IX: Welding and Brazing Qualifications
ASNT SNT-TC-1A
2
, Recommended Practice No. SNT-TC-1A — Personnel Qualification and Certification in Non-Destructive Testing
ASTM A320
3
), Standard Specification for Alloy-Steel and Stainless Steel Bolting Materials for Low-Temperature Service
ASTM A370, Standard Test Methods and Definitions for Mechanical Testing of Steel Products
ASTM A388, Standard Practice for Ultrasonic Examination of Heavy Steel Forgings
ASTM A435, Standard Specification for Straight-Beam Ultrasonic Examination of Steel Plates
ASTM A577, Standard Specification for Ultrasonic Angle-Beam Examination of Steel Plates
AWS QC1
4
, Standard for AWS Certification of Welding Inspectors
EN 287-1
5
), Qualification test of welders — Fusion welding — Part 1: Steels
EN 1092-1, Flanges and their joints — Circular flanges for pipes, valves, fittings and accessories, PN designated — Part 1: Steel flanges
EN 10204:2004, Metallic products — Type of inspection documents
MSS SP-44, Steel Pipeline Flanges
MSS SP-55, Quality Standard for Steel Castings for Valves, Flanges and Fittings and Other Piping Components — Visual Method for Evaluation of Surface Irregularities NACE TM0177-2005, Standard test method. Laboratory testing of metals for resistance to specific forms of environmental cracking in H2S environments
NACE TM0284, Standard Test Method — Evaluation of Pipeline and Pressure Vessel Steels for Resistance to Hydrogen-Induced Cracking
2) American Society of Non-Destructive Testing, P.O. Box 28518, 1711 Arlingate Lane, Columbus, OH 43228-0518, USA.
3) ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959, USA.
4) The American Welding Society, 550 NW LeJeune Road, Miami, FL 33126, USA.
5) CEN, European Committee for Standardization, Central Secretariat, Rue de Stassart 36, B-1050, Brussels, Belgium.
4 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
4.1
ASME rating class
numerical pressure design class defined in ASME B16.34 and used for reference purposes
NOTE The ASME rating class is designated by the word “class” followed by a number.
4.2
bi-directional valve
valve designed for blocking the fluid in both downstream and upstream directions
4.3
bleed
drain or vent
4.4
gate, plug or ball valve that blocks flow into the downstream conduit when in the closed position
NOTE Valves are either single- or double-seated, bi-directional or uni-directional.
4.5
breakaway thrust
breakaway torque
maximum thrust or torque required to operate a valve at maximum pressure differential
4.6
by agreement
agreed between manufacturer and purchaser
4.7
double-block-and-bleed valve
DBB
single valve with two seating surfaces that, in the closed position, provides a seal against pressure from both ends of the valve with a means of venting/bleeding the cavity between the seating surfaces NOTE This valve does not provide positive double isolation when only one side is under pressure. See double-isolation-and-bleed valve (4.8).
4.8
double-isolation-and-bleed valve
DIB
single valve with two seating surfaces, each of which, in the closed position, provides a seal against pressure from a single source, with a means of venting/bleeding the cavity between the seating surfaces NOTE This feature can be provided in one direction or in both directions.
4.9
all parts of a valve drive between the operator and the obturator, including the obturator but excluding the operator
4.10
flow coefficient
Kv
volumetric flow rate of water at a temperature between 5 °C (40 °F) and 40 °C (104 °F) passing through a valve and resulting in a pressure loss of 0,1 MPa (1 bar; 14.5 psi)
NOTE Kv is expressed in SI units of cubic metres per hour.
NOTE KV is related to the flow coefficient CV
, expressed in USC units of US gallons per minute at 15,6°C (60°F) resulting in a 1 psi pressure drop as given by Equation (1):
Kv = (Cv)/(1 , 156)(1)
4.11
full-opening valve
valve with an unobstructed opening, not smaller than the internal bore of the end connections
4.12
handwheel
wheel consisting of a rim connected to a hub, for example by spokes, and used to manually operate a valve requiring multiple turns
4.13
locking device
part or an arrangement of parts for securing a valve in the open and/or closed position
4.14
manual actuator
manual operator
wrench (lever) or hand-wheel with or without a gearbox
4.15
maximum pressure differential
MPD
maximum difference between the upstream and downstream pressure across the obturator at which the obturator may be operated
4.16
nominal pipe size
NPS
numerical imperial designation of size which is common to components in piping systems of any one size
NOTE Nominal pipe size is designated by the abbreviation “NPS” followed by a number.
4.17
nominal pressure class
numerical pressure design class as defined in ISO 7268 and used for reference purposes
NOTE Nominal pressure (PN) class is designated by the abbreviation “PN” followed by a number.
4.18
nominal size
numerical metric designation of size that is common to components in piping systems of any one size
NOTE Nominal size is designated by the abbreviation “DN” followed by a number.
4.19
obturator
closure member
part of a valve, such as a ball, clapper, disc, gate or plug that is positioned in the flow stream to permit or prevent flow
4.20
operator
device (or assembly) for opening or closing a valve
4.21
packing gland
component used to compress the stem packing
4.22
position indicator
device to show the position of the valve obturator
4.23
piggability
capability of a valve to permit the unrestricted passage of a pig
4.24
powered actuator
powered operator
electric, hydraulic or pneumatic device bolted or otherwise attached to the valve for powered opening and closing of the valve
4.25
pressure class
numerical pressure design class expressed in accordance with either the nominal pressure (PN) class or the ASME rating class NOTE In this International Standard, the pressure class is stated by the PN class followed by the ASME rating class between brackets.
4.26
pressure-containing parts
parts, whose failure to function as intended results in a release of contained fluid into the environment
4.27
pressure-controlling parts
parts, such as seat and obturator, intended to prevent or permit the flow of fluids
4.28
process-wetted parts
parts exposed directly to the pipeline fluid
4.29
reduced-opening valve
valve with the opening through the obturator smaller than at the end connection(s)
4.30
seating surfaces
contact surfaces of the obturator and seat which ensure valve sealing
4.31
part that connects the obturator to the operator and which can consist of one or more components
API Specification 6D / ISO 14313
4.32
stem extension assembly
assembly consisting of the stem extension and the stem extension housing
4.33
support ribs or legs
metal structure that provides a stable footing when the valve is set on a fixed base
4.34
through-conduit valve
valve with an unobstructed and continuous cylindrical opening
4.35
uni-directional valve
valve designed for blocking the flow in one direction only
4.36
unless otherwise agreed
<modification of the requirements of this International Standard> unless the manufacturer and purchaser agree on a deviation
4.37
unless otherwise specified
⟨modification of the requirements of this International Standard⟩ unless the purchaser specifies otherwise
4.38
venturi plug valve
valve with a substantially reduced opening through the plug and a smooth transition from each full-opening end to the reduced opening
5 Symbols and abbreviated terms
5.1 Symbols
Cv flow coefficient in USC units
Kv flow coefficient in metric units
t thickness
5.2 Abbreviated terms
BM base metal
CE carbon equivalent
DBB double-block-and-bleed
DIB double isolation-and-bleed
DN nominal size
HAZ heat-affected zone
HBW Brinell hardness, tungsten ball indenter
HRC Rockwell C hardness
HV Vickers hardness
MPD maximum pressure differential
MT magnetic-particle testing
NDE non-destructive examination
NPS nominal pipe size
PN nominal pressure
PQR (weld) procedure qualification record
PT penetrant testing
PWHT post-weld heat treatment
RT radiographic testing
SMYS specified minimum yield strength
USC United States Customary (units)
UT ultrasonic testing
WM weld metal
WPS weld procedure specification
WPQ welder performance qualification
6 Valve types and configurations
6.1 Valve types
6.1.1 Gate valves
Typical configurations for gate valves with flanged and welding ends are shown, for illustration purposes only, in Figures 1 and 2.
Gate valves shall have an obturator that moves in a plane perpendicular to the direction of flow. The gate can be constructed of one piece for slab-gate valves or of two or more pieces for expanding-gate valves.
Gate valves shall be provided with a back seat or secondary stem sealing feature in addition to the primary stem seal.
6.1.2 Lubricated and non-lubricated plug valves
Typical configurations for plug valves with flanged and welding ends are shown, for illustration purposes only, in Figure 3.
Plug valves shall have a cylindrical or conical obturator that rotates about an axis perpendicular to the direction of flow.
6.1.3 Ball valves
Typical configurations for ball valves with flanged or welding ends are shown, for illustration purposes only, in Figures 4, 5 and 6.
Ball valves shall have a spherical obturator that rotates on an axis perpendicular to the direction of flow.
6.1.4 Check valves
Typical configurations for check valves are shown, for illustration purposes only, in Figures 7 to 13. Check valves can also be of the wafer, axial flow and lift type.
Check valves shall have an obturator which responds automatically to block fluid in one direction.
6.2 Valve configurations
6.2.1 Full-opening valves
Full-opening flanged-end valves shall be unobstructed in the fully opened position and shall have an internal bore as specified in Table 1. There is no restriction on the upper limit of valve bore sizes.
Full-opening through-conduit valves shall have a circular bore in the obturator that allows a sphere to pass with a nominal size not less than that specified in Table 1.
Welding-end valves can require a smaller bore at the welding end to mate with the pipe.
Valves with a non-circular opening through the obturator shall not be considered full opening.
6.2.2 Reduced-opening valves
Reduced-opening valves with a circular opening through the obturator shall be supplied with a minimum bore as follows, unless otherwise specified:
— valves DN 300 (NPS 12) and below: one size below nominal size of valve with bore according to Table 1;
— valves DN 350 (NPS 14) to DN 600 (NPS 24): two sizes below nominal size of valve with bore according to Table 1;
— valves above DN 600 (NPS 24): by agreement.
EXAMPLE A DN 400 (NPS 16) – PN 250 (class 1500) reduced-opening ball valve has a minimum bore of 287 mm.
Reduced-opening valves with a non-circular opening through the obturator shall be supplied with a minimum opening by agreement.
| DN | NPS | Minimum bore by class mm | |||
| PN 20 to 100 (Class 150 to 600) | PN 150 (Class 900) | PN 250 (Class 1 500) | PN 420 (Class 2 500) | ||
| 15 | 1/2 | 13 | 13 | 13 | 13 |
| 20 | 3/4 | 19 | 19 | 19 | 19 |
| 25 | 1 | 25 | 25 | 25 | 25 |
| 32 | 11/4 | 32 | 32 | 32 | 32 |
| 40 | 11/2 | 38 | 38 | 38 | 38 |
| 50 | 2 | 49 | 49 | 49 | 42 |
| 65 | 21/2 | 62 | 62 | 62 | 52 |
| 80 | 3 | 74 | 74 | 74 | 62 |
| 100 | 4 | 100 | 100 | 100 | 87 |
| 150 | 6 | 150 | 150 | 144 | 131 |
| 200 | 8 | 201 | 201 | 192 | 179 |
| 250 | 10 | 252 | 252 | 239 | 223 |
| 300 | 12 | 303 | 303 | 287 | 265 |
| 350 | 14 | 334 | 322 | 315 | 292 |
| 400 | 16 | 385 | 373 | 360 | 333 |
| 450 | 18 | 436 | 423 | 406 | 374 |
| 500 | 20 | 487 | 471 | 454 | 419 |
| 550 | 22 | 538 | 522 | 500 | — |
| 600 | 24 | 589 | 570 | 546 | — |
| 650 | 26 | 633 | 617 | 594 | — |
| 700 | 28 | 684 | 665 | 641 | — |
| 750 | 30 | 735 | 712 | 686 | — |
| 800 | 32 | 779 | 760 | 730 | — |
| 850 | 34 | 830 | 808 | 775 | — |
| 900 | 36 | 874 | 855 | 819 | — |
| 950 | 38 | 925 | 904 | — | — |
| 1 000 | 40 | 976 | 956 | — | — |
| 1 050 | 42 | 1 020 | 1 006 | — | — |
| 1 200 | 48 | 1 166 | 1 149 | — | — |
| 1 350 | 54 | 1 312 | — | — | — |
| 1 400 | 56 | 1 360 | — | — | — |
| 1 500 | 60 | 1 458 | — | — | — |
Key
1 stem indicator
2 stem enclosure
3 handwheel
4 yoke nut
5 yoke
6 stem
7 yoke bolting
8 stem packing
9 relief valve
10 bonnet
11 bonnet bolting
12 gate guide
13 gate assembly
14 seat ring
15 body
16 support ribs or legs
17 raised face
18 welding end
19 ring joint
A raised-face face-to-face dimension
B welding-end end-to-end dimension
C ring-joint end-to-end dimension
NOTE See Tables 2 to 6 for dimensions A, B and C.




Key
1 lubricator screw
2 gland studs and nuts
3 gland
4 cover studs and nuts
5 cover
6 cover gasket
7 stem packing
8 lubricant check valve
9 plug
10 body
11 stop collar
12 raised face
13 welding end
14 ring joint
A raised-face face-to-face dimension
B welding-end end-to-end dimension
C ring-joint end-to-end dimension
NOTE See Tables 2 to 6 for dimensions A, B and C.

Key
1 stem seal
2 bonnet cover
3 bonnet
4 body bolting
5 body
6 seat ring
7 stem
8 ball
9 raised face
10 welding end
11 ring joint
A raised-face face-to-face dimension
B welding-end end-to-end dimension
C ring-joint end-to-end dimension

Key
1 stem
2 body cover
3 stem seal
4 body
5 seat ring
6 ball
7 body bolting
8 closure
9 raised face
10 welding end
11 ring joint
A raised-face face-to-face dimension
B welding-end end-to-end dimension
C ring-joint end-to-end dimension
NOTE See Tables 2 to 6 for dimensions A, B and C.

Key
1 stem
2 body cover
3 stem seal
4 body
5 seat ring
6 ball
7 closure
8 raised face
9 welding end
10 ring joint
A raised-face face-to-face dimension
B welding-end end-to-end dimension
C ring-joint end-to-end dimension
NOTE See Tables 2 to 6 for dimensions A, B and C.

Key
1 cover bolting
2 cover
3 body
4 clapper disc arm
5 shaft
6 clapper disc
7 seat ring
8 support ribs or legs
9 raised face
10 welding end
11 ring joint
12 direction of flow
A raised-face face-to-face dimension
B welding-end end-to-end dimension
C ring-joint end-to-end dimension
NOTE See Tables 2 to 6 for dimensions A, B and C.


Key
1 cover bolting
2 cover
3 body
4 clapper disc arm
5 shaft
6 seat ring
7 clapper disc
8 support ribs or legs
9 raised face
10 welding end
11 ring joint
12 direction of flow
A raised-face face-to-face dimension
B welding-end end-to-end dimension
C ring-joint end-to-end dimension
NOTE See Tables 2 to 6 for dimensions A, B and C.


1 body
2 hinge
4 closure plate/stud assembly
5 seat ring

6 bearing spacers
Figure 9 — Single-plate wafer-type check valve, long pattern
7 hinge pin
8 hinge pin retainers
Key
body
closure plate
stop pin
spring
hinge pin
plate lug bearings
body lug bearings
stop pin retainers
hinge pin retainers
spring bearings
direction of flow



Key
body
clapper
pin
clapper seal
body seal
lifting eye
direction of flow
Figure 11 — Single-plate wafer-type check valve, short pattern


7 Design
7.1 Design standards and calculations
Pressure-containing parts, including bolting, shall be designed with materials specified in Clause 8.
Design and calculations for pressure-containing elements shall be in accordance with an internationally recognized design code or standard with consideration for pipe loads, operating forces, etc. The choice of standard shall be by agreement. NOTE 1 Examples of internationally recognized design codes or standards are ASME Section VIII Division 1 or Division 2, ASME B16.34, EN 12516-1 and EN 13445-3.
The allowable stress values shall be consistent with the selected design code or standard.
If the selected design code or standard specifies a test pressure less than 1,5 times the design pressure, then the design pressure for the body calculation shall be increased such that the hydrostatic test pressure in 11.3 can be applied. NOTE 2 Some design codes or standards require a consistent and specific application of requirements for fabrication and testing, including NDE.
7.2 Pressure and temperature rating
The nominal pressure (PN) class or the ASME rating class shall be used for the specification of the required pressure class.
Valves covered by this International Standard shall be furnished in one of the following classes:
— PN 20 (class 150);
— PN 50 (class 300);
— PN 64 (class 400);
— PN 100 (class 600);
— PN 150 (class 900);
— PN 250 (class 1500);
— PN 420 (class 2500).
Pressure-temperature ratings for class-rated valves shall be in accordance with the applicable rating table for the appropriate material group in ASME B16.34. Pressure-temperature ratings for PN-rated valves shall be in accordance with the applicable rating table for the appropriate material group in EN 1092-1.
If intermediate design pressures and temperatures are specified by the purchaser, the pressure-temperature rating shall be determined by linear interpolation. Pressure-temperature ratings for valves made from materials not covered by ASME B16.34 and EN 1092-1 shall be determined from the material properties in accordance with the applicable design standard.
NOTE Non-metallic parts can limit maximum pressures and minimum and maximum operating temperatures.
The maximum operating pressure at the minimum and maximum operating temperatures shall be marked on the nameplate.
7.3 Sizes
Valves constructed to this International Standard shall be furnished in nominal sizes as listed in Table 1.
NOTE In this International Standard, DN sizes are stated first followed by the equivalent NPS size between brackets.
Except for reduced-opening valves, valve sizes shall be specified by the nominal sizes (DN) or nominal pipe size (NPS).
Reduced-opening valves with a circular opening shall be specified by the nominal size of the end connections and the nominal size of the reduced opening in accordance with Table 1. EXAMPLE 1 A DN 400 – PN 20 valve with a reduced 303 mm diameter circular opening shall be specified as DN 400 (NPS 16) × DN 300 (NPS 12). Reduced-opening valves with a non-circular opening and reduced-opening check valves shall be designated as reduced-bore valves and specified by the nominal size corresponding to the end connections followed by the letter “R”. EXAMPLE 2 Reduced-bore valve with DN 400 (NPS 16) end connections and a 381 mm × 305 mm rectangular opening shall be specified as 400R.
7.4 Face-to-face and end-to-end dimensions
Unless otherwise agreed, face-to-face (A) and end-to-end (B and C) dimensions of valves shall be in accordance with Tables 2 to 6; see Figures 1 to 13 for diagrams of dimensions A, B and C. Face-to-face and end-to-end dimensions for valve sizes not specified in Tables 2 to 6 shall be in accordance with ASME B16.10. Face-to-face and end-to-end dimensions not shown in Table 2 to Table 6 or in ASME B16.10 shall be established by agreement.
The length of valves having one welding end and one flanged end shall be determined by adding half the length of a flanged-end valve to half the length of a welding-end valve.
Tolerances on the face-to-face and end-to-end dimensions shall be ±2 mm for valve sizes DN 250 (NPS 10) and smaller, and ±3 mm for valve sizes DN 300 (NPS 12) and larger. The nominal size and face-to-face or end-to-end dimensions shall be stated on the nameplate if not specified in, or not in accordance with, Tables 2 to 6.
| DN | NPS | Dimension mm | |||||
| Raised faceA | Welding endB | Ring jointC | Raised faceA | Welding endB | Ring jointC | ||
| PN 20 (class 150) | PN 50 (class 300) | ||||||
| 50 | 2 | 178 | 216 | 191 | 216 | 216 | 232 |
| 65 | 21⁄2 | 191 | 241 | 203 | 241 | 241 | 257 |
| 80 | 3 | 203 | 283 | 216 | 283 | 283 | 298 |
| 100 | 4 | 229 | 305 | 241 | 305 | 305 | 321 |
| 150 | 6 | 267 | 403 | 279 | 403 | 403 | 419 |
| 200 | 8 | 292 | 419 | 305 | 419 | 419 | 435 |
| 250 | 10 | 330 | 457 | 343 | 457 | 457 | 473 |
| 300 | 12 | 356 | 502 | 368 | 502 | 502 | 518 |
| 350 | 14 | 381 | 572 | 394 | 762 | 762 | 778 |
| 400 | 16 | 406 | 610 | 419 | 838 | 838 | 854 |
| 450 | 18 | 432 | 660 | 445 | 914 | 914 | 930 |
| 500 | 20 | 457 | 711 | 470 | 991 | 991 | 1010 |
| 550 | 22 | — | — | — | 1092 | 1092 | 1114 |
| 600 | 24 | 508 | 813 | 521 | 1143 | 1143 | 1165 |
| 650 | 26 | 559 | 864 | — | 1245 | 1245 | 1270 |
| 700 | 28 | 610 | 914 | — | 1346 | 1346 | 1372 |
| 750 | 30 | 610a | 914 | — | 1397 | 1397 | 1422 |
| 800 | 32 | 711 | 965 | — | 1524 | 1524 | 1553 |
| 850 | 34 | 762 | 1016 | — | 1626 | 1626 | 1654 |
| 900 | 36 | 711b | 1016 | — | 1727 | 1727 | 1756 |
| DN | NPS | Dimension mm | |||||
| Raised faceA | Welding endB | Ring jointC | Raised faceA | Welding endB | Ring jointC | ||
| PN 64 (class 400) | PN 100 (class 600) | ||||||
| 50 | 2 | 292 | 292 | 295 | 292 | 292 | 295 |
| 65 | 21⁄2 | 330 | 330 | 333 | 330 | 330 | 333 |
| 80 | 3 | 356 | 356 | 359 | 356 | 356 | 359 |
| 100 | 4 | 406 | 406 | 410 | 432 | 432 | 435 |
| 150 | 6 | 495 | 495 | 498 | 559 | 559 | 562 |
| 200 | 8 | 597 | 597 | 600 | 660 | 660 | 664 |
| 250 | 10 | 673 | 673 | 676 | 787 | 787 | 791 |
| 300 | 12 | 762 | 762 | 765 | 838 | 838 | 841 |
| 350 | 14 | 826 | 826 | 829 | 889 | 889 | 892 |
| 400 | 16 | 902 | 902 | 905 | 991 | 991 | 994 |
| 450 | 18 | 978 | 978 | 981 | 1 092 | 1 092 | 1 095 |
| 500 | 20 | 1 054 | 1 054 | 1 060 | 1 194 | 1 194 | 1 200 |
| 550 | 22 | 1 143 | 1 143 | 1 153 | 1 295 | 1 295 | 1 305 |
| 600 | 24 | 1 232 | 1 232 | 1 241 | 1 397 | 1 397 | 1 407 |
| 650 | 26 | 1 308 | 1 308 | 1 321 | 1 448 | 1 448 | 1 461 |
| 700 | 28 | 1 397 | 1 397 | 1 410 | 1 549 | 1 549 | 1 562 |
| 750 | 30 | 1 524 | 1 524 | 1 537 | 1 651 | 1 651 | 1 664 |
| 800 | 32 | 1 651 | 1 651 | 1 667 | 1 778 | 1 778 | 1 794 |
| 850 | 34 | 1 778 | 1 778 | 1 794 | 1 930 | 1 930 | 1 946 |
| 900 | 36 | 1 880 | 1 880 | 1 895 | 2 083 | 2 083 | 2 099 |
| DN | NPS | Dimension mm | |||||
| Raised face A | Welding end B | Ring joint C | Raised face A | Welding end B | Ring joint C | ||
| PN 150 (class 900) | PN 250 (class 1500) | ||||||
| 50 | 2 | 368 | 368 | 371 | 368 | 368 | 371 |
| 65 | 21⁄2 | 419 | 419 | 422 | 419 | 419 | 422 |
| 80 | 3 | 381 | 381 | 384 | 470 | 470 | 473 |
| 100 | 4 | 457 | 457 | 460 | 546 | 546 | 549 |
| 150 | 6 | 610 | 610 | 613 | 705 | 705 | 711 |
| 200 | 8 | 737 | 737 | 740 | 832 | 832 | 841 |
| 250 | 10 | 838 | 838 | 841 | 991 | 991 | 1 000 |
| 300 | 12 | 965 | 965 | 968 | 1 130 | 1 130 | 1 146 |
| 350 | 14 | 1 029 | 1 029 | 1 038 | 1 257 | 1 257 | 1 276 |
| 400 | 16 | 1 130 | 1 130 | 1 140 | 1 384 | 1 384 | 1 407 |
| 450 | 18 | 1 219 | 1 219 | 1 232 | 1 537 | 1 537 | 1 559 |
| 500 | 20 | 1 321 | 1 321 | 1 334 | 1 664 | 1 664 | 1 686 |
| 550 | 22 | — | — | — | — | — | — |
| 600 | 24 | 1 549 | 1 549 | 1 568 | 1 943 | 1 943 | 1 972 |
| PN 420 (class 2500) | |||||||
| 50 | 2 | 451 | 451 | 454 | |||
| 65 | 21⁄2 | 508 | 508 | 514 | |||
| 80 | 3 | 578 | 578 | 584 | |||
| 100 | 4 | 673 | 673 | 683 | |||
| 150 | 6 | 914 | 914 | 927 | |||
| 200 | 8 | 1 022 | 1 022 | 1 038 | |||
| 250 | 10 | 1 270 | 1 270 | 1 292 | |||
| 300 | 12 | 1 422 | 1 422 | 1 445 | |||
| a Through-conduit valves shall be 660 mm. b Through-conduit valves shall be 813 mm. | |||||||
| DN | NPS | Dimension mm | |||||||||||
| Short-pattern | Regular-pattern | Venturi-pattern | Round-port, full-bore | ||||||||||
| Raised face A | Welding end B | Ring joint C | Raised face A | Welding end B | Ring joint C | Raised face A | Welding end B | Ring joint C | Raised face A | Welding end B | Ring joint C | ||
| PN 20 (class 150) | |||||||||||||
| 50 | 2 | 178 | 267 | 191 | — | — | — | — | — | — | 267 | — | 279 |
| 65 | 21⁄2 | 191 | 305 | 203 | — | — | — | — | — | — | 298 | — | 311 |
| 80 | 3 | 203 | 330 | 216 | — | — | — | — | — | — | 343 | — | 356 |
| 100 | 4 | 229 | 356 | 241 | — | — | — | — | — | — | 432 | — | 445 |
| 150 | 6 | 267 | 457 | 279 | 394 | — | 406 | — | — | — | 546 | — | 559 |
| 200 | 8 | 292 | 521 | 305 | 457 | — | 470 | — | — | — | 622 | — | 635 |
| 250 | 10 | 330 | 559 | 343 | 533 | — | 546 | 533 | 559 | 546 | 660 | — | 673 |
| 300 | 12 | 356 | 635 | 368 | 610 | — | 622 | 610 | 635 | 622 | 762 | — | 775 |
| 350 | 14 | — | — | — | — | — | — | 686 | 686 | 699 | — | — | — |
| 400 | 16 | — | — | — | — | — | — | 762 | 762 | 775 | — | — | — |
| 450 | 18 | — | — | — | — | — | — | 864 | 864 | 876 | — | — | — |
| 500 | 20 | — | — | — | — | — | — | 914 | 914 | 927 | — | — | — |
| 600 | 24 | — | — | — | — | — | — | 1067 | 1067 | 1080 | — | — | — |
| PN 50 (class 300) | |||||||||||||
| 50 | 2 | 216 | 267 | 232 | — | — | — | — | — | — | 283 | 283 | 298 |
| 65 | 21⁄2 | 241 | 305 | 257 | — | — | — | — | — | — | 330 | 330 | 346 |
| 80 | 3 | 283 | 330 | 298 | — | — | — | — | — | — | 387 | 387 | 403 |
| 100 | 4 | 305 | 356 | 321 | — | — | — | — | — | — | 457 | 457 | 473 |
| 150 | 6 | 403 | 457 | 419 | 403 | — | 419 | 403 | 457 | 419 | 559 | 559 | 575 |
| 200 | 8 | 419 | 521 | 435 | 502 | — | 518 | 419 | 521 | 435 | 686 | 686 | 702 |
| 250 | 10 | 457 | 559 | 473 | 568 | — | 584 | 457 | 559 | 473 | 826 | 826 | 841 |
| 300 | 12 | 502 | 635 | 518 | — | — | — | 502 | 635 | 518 | 965 | 965 | 981 |
| 350 | 14 | — | — | — | — | — | — | 762 | 762 | 778 | — | — | — |
| 400 | 16 | — | — | — | — | — | — | 838 | 838 | 854 | — | — | — |
| 450 | 18 | — | — | — | 914 | — | 930 | 914 | 914 | 930 | — | — | — |
| 500 | 20 | — | — | — | 991 | — | 1010 | 991 | 991 | 1010 | — | — | — |
| 550 | 22 | — | — | — | 1092 | — | 1114 | 1092 | 1092 | 1114 | — | — | — |
| 600 | 24 | — | — | — | 1143 | — | 1165 | 1143 | 1143 | 1165 | — | — | — |
| 650 | 26 | — | — | — | 1245 | — | 1270 | 1245 | 1245 | 1270 | — | — | — |
| 700 | 28 | — | — | — | 1346 | — | 1372 | 1346 | 1346 | 1372 | — | — | — |
| 750 | 30 | — | — | — | 1397 | — | 1422 | 1397 | 1397 | 1422 | — | — | — |
| 800 | 32 | — | — | — | 1524 | — | 1553 | 1524 | 1524 | 1553 | — | — | — |
| 850 | 34 | — | — | — | 1626 | — | 1654 | 1626 | 1626 | 1654 | — | — | — |
| 900 | 36 | — | — | — | 1727 | — | 1756 | 1727 | 1727 | 1756 | — | — | — |
| DN | NPS | Dimension mm | |||||||||||
| Short-pattern | Regular-pattern | Venturi-pattern | Round-port, full-bore | ||||||||||
| Raised face A | Welding end B | Ring joint C | Raised face A | Welding end B | Ring joint C | Raised face A | Welding end B | Ring joint C | Raised face A | Welding end B | Ring joint C | ||
| PN 64 (class 400) | |||||||||||||
| 50 | 2 | — | — | — | 292 | 292 | 295 | — | — | — | 330 | — | 333 |
| 65 | 21⁄2 | — | — | — | 330 | 330 | 333 | — | — | — | 381 | — | 384 |
| 80 | 3 | — | — | — | 356 | 356 | 359 | — | — | — | 445 | — | 448 |
| 100 | 4 | — | — | — | 406 | 406 | 410 | — | — | — | 483 | 559 | 486 |
| 150 | 6 | — | — | — | 495 | 495 | 498 | 495 | 495 | 498 | 610 | 711 | 613 |
| 200 | 8 | — | — | — | 597 | 597 | 600 | 597 | 597 | 600 | 737 | 845 | 740 |
| 250 | 10 | — | — | — | 673 | 673 | 676 | 673 | 673 | 676 | 889 | 889 | 892 |
| 300 | 12 | — | — | — | 762 | 762 | 765 | 762 | 762 | 765 | 1016 | 1016 | 1019 |
| 350 | 14 | — | — | — | — | — | — | 826 | 826 | 829 | — | — | — |
| 400 | 16 | — | — | — | — | — | — | 902 | 902 | 905 | — | — | — |
| 450 | 18 | — | — | — | — | — | — | 978 | 978 | 981 | — | — | — |
| 500 | 20 | — | — | — | — | — | — | 1054 | 1054 | 1060 | — | — | — |
| 550 | 22 | — | — | — | — | — | — | 1143 | 1143 | 1159 | — | — | — |
| 600 | 24 | — | — | — | — | — | — | 1232 | 1232 | 1241 | — | — | — |
| 650 | 26 | — | — | — | — | — | — | 1308 | 1308 | 1321 | — | — | — |
| 700 | 28 | — | — | — | — | — | — | 1397 | 1397 | 1410 | — | — | — |
| 750 | 30 | — | — | — | — | — | — | 1524 | 1524 | 1537 | — | — | — |
| 800 | 32 | — | — | — | — | — | — | 1651 | 1651 | 1667 | — | — | — |
| 850 | 34 | — | — | — | — | — | — | 1778 | 1778 | 1794 | — | — | — |
| 900 | 36 | — | — | — | — | — | — | 1880 | 1880 | 1895 | — | — | — |
| DN | NPS | Dimension mm | ||||||||
| Regular-pattern | Venturi-pattern | Round-port, full-bore | ||||||||
| Raised face A | Welding end B | Ring joint C | Raised face A | Welding end B | Ring joint C | Raised face A | Welding end B | Ring joint C | ||
| PN 100 (class 600) | ||||||||||
| 50 | 2 | 292 | 292 | 295 | — | — | — | 330 | — | 333 |
| 65 | 21⁄2 | 330 | 330 | 333 | — | — | — | 381 | — | 384 |
| 80 | 3 | 356 | 356 | 359 | — | — | — | 445 | — | 448 |
| 100 | 4 | 432 | 432 | 435 | — | — | — | 508 | 559 | 511 |
| 150 | 6 | 559 | 559 | 562 | 559 | 559 | 562 | 660 | 711 | 664 |
| 200 | 8 | 660 | 660 | 664 | 660 | 660 | 664 | 794 | 845 | 797 |
| 250 | 10 | 787 | 787 | 791 | 787 | 787 | 791 | 940 | 1016 | 943 |
| 300 | 12 | — | — | — | 838 | 838 | 841 | 1067 | 1067 | 1070 |
| 350 | 14 | — | — | — | 889 | 889 | 892 | — | — | — |
| 400 | 16 | — | — | — | 991 | 991 | 994 | — | — | — |
| 450 | 18 | — | — | — | 1092 | 1092 | 1095 | — | — | — |
| 500 | 20 | — | — | — | 1194 | 1194 | 1200 | — | — | — |
| 550 | 22 | — | — | — | 1295 | 1295 | 1305 | — | — | — |
| 600 | 24 | — | — | — | 1397 | 1397 | 1407 | — | — | — |
| 650 | 26 | — | — | — | 1448 | 1448 | 1461 | — | — | — |
| 750 | 30 | — | — | — | 1651 | 1651 | 1664 | — | — | — |
| 800 | 32 | — | — | — | 1778 | 1778 | 1794 | — | — | — |
| 850 | 34 | — | — | — | 1930 | 1930 | 1946 | — | — | — |
| 900 | 36 | — | — | — | 2083 | 2083 | 2099 | — | — | — |
| PN 150 (class 900) | ||||||||||
| 50 | 2 | 368 | — | 371 | — | — | — | 381 | — | 384 |
| 65 | 21⁄2 | 419 | — | 422 | — | — | — | 432 | — | 435 |
| 80 | 3 | 381 | 381 | 384 | — | — | — | 470 | — | 473 |
| 100 | 4 | 457 | 457 | 460 | — | — | — | 559 | — | 562 |
| 150 | 6 | 610 | 610 | 613 | 610 | 610 | 613 | 737 | — | 740 |
| 200 | 8 | 737 | 737 | 740 | 737 | 737 | 740 | 813 | — | 816 |
| 250 | 10 | 838 | 838 | 841 | 838 | 838 | 841 | 965 | — | 968 |
| 300 | 12 | — | — | — | 965 | 965 | 968 | 1118 | — | 1121 |
| 400 | 16 | — | — | — | 1130 | 1130 | 1140 | — | — | — |
| DN | NPS | Dimension mm | ||||||||
| Regular-pattern | Venturi-pattern | Round-port, full-bore | ||||||||
| Raised face A | Welding end B | Ring joint C | Raised face A | Welding end B | Ring joint C | Raised face A | Welding end B | Ring joint C | ||
| PN 250 (class 1500) | ||||||||||
| 50 | 2 | 368 | — | 371 | — | — | — | 391 | — | 394 |
| 65 | 21⁄2 | 419 | — | 422 | — | — | — | 454 | — | 457 |
| 80 | 3 | 470 | 470 | 473 | — | — | — | 524 | — | 527 |
| 100 | 4 | 546 | 546 | 549 | — | — | — | 625 | — | 629 |
| 150 | 6 | 705 | 705 | 711 | 705 | 705 | 711 | 787 | — | 794 |
| 200 | 8 | 832 | 832 | 841 | 832 | 832 | 841 | 889 | — | 899 |
| 250 | 10 | 991 | 991 | 1000 | 991 | 991 | 1000 | 1067 | — | 1076 |
| 300 | 12 | 1130 | 1130 | 1146 | 1130 | 1130 | 1146 | 1219 | — | 1235 |
| PN 420 (class 2500) | ||||||||||
| 50 | 2 | 451 | — | 454 | — | — | — | — | — | — |
| 65 | 21⁄2 | 508 | — | 514 | — | — | — | — | — | — |
| 80 | 3 | 578 | — | 584 | — | — | — | — | — | — |
| 100 | 4 | 673 | — | 683 | — | — | — | — | — | — |
| 150 | 6 | 914 | — | 927 | — | — | — | — | — | — |
| 200 | 8 | 1022 | — | 1038 | — | — | — | — | — | — |
| 250 | 10 | 1270 | — | 1292 | — | — | — | — | — | — |
| 300 | 12 | 1422 | — | 1445 | — | — | — | — | — | — |
| DN | NPS | Dimension mm | |||||
| Full-bore and reduced-bore | Short-pattern, full-bore and reduced-bore | ||||||
| Raised face A | Welding end B | Ring joint C | Raised face A | Welding end B | Ring joint C | ||
| PN 20 (class 150) | |||||||
| 50 | 2 | 178 | 216 | 191 | — | — | — |
| 65 | 21⁄2 | 191 | 241 | 203 | — | — | — |
| 80 | 3 | 203 | 283 | 216 | — | — | — |
| 100 | 4 | 229 | 305 | 241 | — | — | — |
| 150 | 6 | 394 | 457 | 406 | 267 | 403 | 279 |
| 200 | 8 | 457 | 521 | 470 | 292 | 419 | 305 |
| 250 | 10 | 533 | 559 | 546 | 330 | 457 | 343 |
| 300 | 12 | 610 | 635 | 622 | 356 | 502 | 368 |
| 350 | 14 | 686 | 762 | 699 | — | — | — |
| 400 | 16 | 762 | 838 | 775 | — | — | — |
| 450 | 18 | 864 | 914 | 876 | — | — | — |
| 500 | 20 | 914 | 991 | 927 | — | — | — |
| 550 | 22 | — | — | — | — | — | — |
| 600 | 24 | 1067 | 1143 | 1080 | — | — | — |
| 650 | 26 | 1143 | 1245 | — | — | — | — |
| 700 | 28 | 1245 | 1346 | — | — | — | — |
| 750 | 30 | 1295 | 1397 | — | — | — | — |
| 800 | 32 | 1372 | 1524 | — | — | — | — |
| 850 | 34 | 1473 | 1626 | — | — | — | — |
| 900 | 36 | 1524 | 1727 | — | — | — | — |
| 950 | 38 | — | — | — | — | — | — |
| 1000 | 40 | — | — | — | — | — | — |
| 1100 | 42 | — | — | — | — | — | — |
| 1200 | 48 | — | — | — | — | — | — |
| 1400 | 54 | — | — | — | — | — | — |
| 1500 | 60 | — | — | — | — | — | — |
| DN | NPS | Dimension mm | |||||
| Full-bore and reduced-bore | Short-pattern, full-bore and reduced-bore | ||||||
| Raised face A | Welding end B | Ring joint C | Raised face A | Welding end B | Ring joint C | ||
| PN 50 (class 300) | |||||||
| 50 | 2 | 216 | 216 | 232 | — | — | — |
| 65 | 21⁄2 | 241 | 241 | 257 | — | — | — |
| 80 | 3 | 283 | 283 | 298 | — | — | — |
| 100 | 4 | 305 | 305 | 321 | — | — | — |
| 150 | 6 | 457 | 457 | 419 | — | — | — |
| 200 | 8 | 502 | 521 | 518 | 419 | 419 | 435 |
| 250 | 10 | 568 | 559 | 584 | 457 | 457 | 473 |
| 300 | 12 | 648 | 635 | 664 | 502 | 502 | 518 |
| 350 | 14 | 762 | 762 | 778 | — | — | — |
| 400 | 16 | 838 | 838 | 854 | — | — | — |
| 450 | 18 | 914 | 914 | 930 | — | — | — |
| 500 | 20 | 991 | 991 | 1010 | — | — | — |
| 550 | 22 | 1092 | 1092 | 1114 | — | — | — |
| 600 | 24 | 1143 | 1143 | 1165 | — | — | — |
| 650 | 26 | 1245 | 1245 | 1270 | — | — | — |
| 700 | 28 | 1346 | 1346 | 1372 | — | — | — |
| 750 | 30 | 1397 | 1397 | 1422 | — | — | — |
| 800 | 32 | 1524 | 1524 | 1553 | — | — | — |
| 850 | 34 | 1626 | 1626 | 1654 | — | — | — |
| 900 | 36 | 1727 | 1727 | 1756 | — | — | — |
| 950 | 38 | — | — | — | — | — | — |
| 1000 | 40 | — | — | — | — | — | — |
| 1100 | 42 | — | — | — | — | — | — |
| 1200 | 48 | — | — | — | — | — | — |
| 1400 | 54 | — | — | — | — | — | — |
| 1500 | 60 | — | — | — | — | — | — |
| DN | NPS | Dimension mm | |||||
| Full-bore and reduced-bore | Full-bore and reduced-bore | ||||||
| Raised face A | Welding end B | Ring joint C | Raised face A | Welding end B | Ring joint C | ||
| PN 64 (class 400) | PN 100 (class 600) | ||||||
| 50 | 2 | — | — | — | 292 | 292 | 295 |
| 65 | 21⁄2 | — | — | — | 330 | 330 | 333 |
| 80 | 3 | — | — | — | 356 | 356 | 359 |
| 100 | 4 | 406 | 406 | 410 | 432 | 432 | 435 |
| 150 | 6 | 495 | 495 | 498 | 559 | 559 | 562 |
| 200 | 8 | 597 | 597 | 600 | 660 | 660 | 664 |
| 250 | 10 | 673 | 673 | 676 | 787 | 787 | 791 |
| 300 | 12 | 762 | 762 | 765 | 838 | 838 | 841 |
| 350 | 14 | 826 | 826 | 829 | 889 | 889 | 892 |
| 400 | 16 | 902 | 902 | 905 | 991 | 991 | 994 |
| 450 | 18 | 978 | 978 | 981 | 1 092 | 1 092 | 1 095 |
| 500 | 20 | 1 054 | 1 054 | 1 060 | 1 194 | 1 194 | 1 200 |
| 550 | 22 | 1 143 | 1 143 | 1 153 | 1 295 | 1 295 | 1 305 |
| 600 | 24 | 1 232 | 1 232 | 1 241 | 1 397 | 1 397 | 1 407 |
| 650 | 26 | 1 308 | 1 308 | 1 321 | 1 448 | 1 448 | 1 461 |
| 700 | 28 | 1 397 | 1 397 | 1 410 | 1 549 | 1 549 | 1 562 |
| 750 | 30 | 1 524 | 1 524 | 1 537 | 1 651 | 1 651 | 1 664 |
| 800 | 32 | 1 651 | 1 651 | 1 667 | 1 778 | 1 778 | 1 794 |
| 850 | 34 | 1 778 | 1 778 | 1 794 | 1 930 | 1 930 | 1 946 |
| 900 | 36 | 1 880 | 1 880 | 1 895 | 2 083 | 2 083 | 2 099 |
| 950 | 38 | — | — | — | — | — | — |
| 1 000 | 40 | — | — | — | — | — | — |
| 1 100 | 42 | — | — | — | — | — | — |
| 1 200 | 48 | — | — | — | — | — | — |
| DN | NPS | Dimension mm | |||||
| Full-bore and reduced-bore | Full-bore and reduced bore | ||||||
| Raised face A | Welding end B | Ring joint C | Raised face A | Welding end B | Ring joint C | ||
| PN 150 (class 900) | PN 250 (class 1500) | ||||||
| 50 | 2 | 368 | 368 | 371 | 368 | 368 | 371 |
| 65 | 21⁄2 | 419 | 419 | 422 | 419 | 419 | 422 |
| 80 | 3 | 381 | 381 | 384 | 470 | 470 | 473 |
| 100 | 4 | 457 | 457 | 460 | 546 | 546 | 549 |
| 150 | 6 | 610 | 610 | 613 | 705 | 705 | 711 |
| 200 | 8 | 737 | 737 | 740 | 832 | 832 | 841 |
| 250 | 10 | 838 | 838 | 841 | 991 | 991 | 1 000 |
| 300 | 12 | 965 | 965 | 968 | 1 130 | 1 130 | 1 146 |
| 350 | 14 | 1 029 | 1 029 | 1 038 | 1 257 | 1 257 | 1 276 |
| 400 | 16 | 1 130 | 1 130 | 1 140 | 1 384 | 1 384 | 1 407 |
| 450 | 18 | 1 219 | 1 219 | 1 232 | 1 537 | — | 1559 |
| 500 | 20 | 1 321 | 1 321 | 1 334 | 1 664 | — | 1686 |
| 550 | 22 | — | — | — | — | — | — |
| 600 | 24 | 1 549 | 1 549 | 1 568 | — | 1972 | |
| 650 | 26 | 1 651 | — | 1 673 | 1 943 | ||
| 700 | 28 | — | — | — | |||
| 750 | 30 | 1 880 | — | 1 902 | |||
| 800 | 32 | — | — | — | |||
| 850 | 34 | — | — | — | |||
| 900 | 36 | 2 286 | — | 2 315 | |||
| PN 420 (class 2500) | |||||||
| 50 | 2 | 451 | 451 | 454 | |||
| 65 | 21⁄2 | 508 | 508 | 540 | |||
| 80 | 3 | 578 | 578 | 584 | |||
| 100 | 4 | 673 | 673 | 683 | |||
| 150 | 6 | 914 | 914 | 927 | |||
| 200 | 8 | 1 022 | 1 022 | 1 038 | |||
| 250 | 10 | 1 270 | 1 270 | 1 292 | |||
| 300 | 12 | 1 422 | 1 422 | 1 445 | |||
| DN | NPS | Dimension mm | |||||||||||
| PN 20 (class 150) | PN 50 (class 300) | PN 64 (class 400) | PN 100 (class 600) | ||||||||||
| Raised face A | Welding end B | Ring joint C | Raised face A | Welding end B | Ring joint C | Raised face A | Welding end B | Ring joint C | Raised face A | Welding end B | Ring joint C | ||
| 50 | 2 | 203 | 203 | 216 | 267 | 267 | 283 | 292 | 292 | 295 | 292 | 292 | 295 |
| 65 | 21⁄2 | 216 | 216 | 229 | 292 | 292 | 308 | 330 | 330 | 333 | 330 | 330 | 333 |
| 80 | 3 | 241 | 241 | 254 | 318 | 318 | 333 | 356 | 356 | 359 | 356 | 356 | 359 |
| 100 | 4 | 292 | 292 | 305 | 356 | 356 | 371 | 406 | 406 | 410 | 432 | 432 | 435 |
| 150 | 6 | 356 | 356 | 368 | 445 | 445 | 460 | 495 | 495 | 498 | 559 | 559 | 562 |
| 200 | 8 | 495 | 495 | 508 | 533 | 533 | 549 | 597 | 597 | 600 | 660 | 660 | 664 |
| 250 | 10 | 622 | 622 | 635 | 622 | 622 | 638 | 673 | 673 | 676 | 787 | 787 | 791 |
| 300 | 12 | 699 | 699 | 711 | 711 | 711 | 727 | 762 | 762 | 765 | 838 | 838 | 841 |
| 350 | 14 | 787 | 787 | 800 | 838 | 838 | 854 | 889 | 889 | 892 | 889 | 889 | 892 |
| 400 | 16 | 864 | 864 | 876 | 864 | 864 | 879 | 902 | 902 | 905 | 991 | 991 | 994 |
| 450 | 18 | 978 | 978 | 991 | 978 | 978 | 994 | 1016 | 1016 | 1019 | 1092 | 1092 | 1095 |
| 500 | 20 | 978 | 978 | 991 | 1016 | 1016 | 1035 | 1054 | 1054 | 1060 | 1194 | 1194 | 1200 |
| 550 | 22 | 1067 | 1067 | 1080 | 1118 | 1118 | 1140 | 1143 | 1143 | 1153 | 1295 | 1295 | 1305 |
| 600 | 24 | 1295 | 1295 | 1308 | 1346 | 1346 | 1368 | 1397 | 1397 | 1407 | 1397 | 1397 | 1407 |
| 650 | 26 | 1295 | 1295 | — | 1346 | 1346 | 1372 | 1397 | 1397 | 1410 | 1448 | 1448 | 1461 |
| 700 | 28 | 1448 | 1448 | — | 1499 | 1499 | 1524 | 1600 | 1600 | 1613 | 1600 | 1600 | 1613 |
| 750 | 30 | 1524 | 1524 | — | 1594 | 1594 | 1619 | 1651 | 1651 | 1664 | 1651 | 1651 | 1664 |
| 900 | 36 | 1956 | 1956 | — | 2083 | 2083 | — | 2083 | 2083 | — | 2083 | 2083 | — |
| 950 | 38 | — | — | — | — | — | — | — | — | — | — | — | — |
| 1000 | 40 | — | — | — | — | — | — | — | — | — | — | — | — |
| 1100 | 42 | — | — | — | — | — | — | — | — | — | — | — | — |
| 1200 | 48 | — | — | — | — | — | — | — | — | — | — | — | — |
| 1400 | 54 | — | — | — | — | — | — | — | — | — | — | — | — |
| 1500 | 60 | — | — | — | — | — | — | — | — | — | — | — | — |
| DN | NPS | Dimension mm | ||||||||
| PN 150 (class 900) | PN 250 (class 1500) | PN 420 (class 2500) | ||||||||
| Raised face A | Welding end B | Ring joint C | Raised face A | Welding end B | Ring joint C | Raised face A | Welding end B | Ring joint C | ||
| 50 | 2 | 368 | 368 | 371 | 368 | 368 | 371 | 451 | 451 | 454 |
| 65 | 21⁄2 | 419 | 419 | 422 | 419 | 419 | 422 | 508 | 508 | 514 |
| 80 | 3 | 381 | 381 | 384 | 470 | 470 | 473 | 578 | 578 | 584 |
| 100 | 4 | 457 | 457 | 460 | 546 | 546 | 549 | 673 | 673 | 683 |
| 150 | 6 | 610 | 610 | 613 | 705 | 705 | 711 | 914 | 914 | 927 |
| 200 | 8 | 737 | 737 | 740 | 832 | 832 | 841 | 1 022 | 1 022 | 1 038 |
| 250 | 10 | 838 | 838 | 841 | 991 | 991 | 1 000 | 1 270 | 1 270 | 1 292 |
| 300 | 12 | 965 | 965 | 968 | 1 130 | 1 130 | 1 146 | 1 422 | 1 422 | 1 445 |
| 350 | 14 | 1 029 | 1 029 | 1 038 | 1 257 | 1 257 | 1 276 | — | — | — |
| 400 | 16 | 1 130 | 1 130 | 1 140 | 1 384 | 1 384 | 1 407 | — | — | — |
| 450 | 18 | 1 219 | 1 219 | 1 232 | 1 537 | 1 537 | 1 559 | — | — | — |
| 500 | 20 | 1 321 | 1 321 | 1 334 | 1 664 | 1 664 | 1 686 | — | — | — |
| 600 | 24 | 1 549 | 1 549 | 1 568 | 1 943 | 1 943 | 1 972 | — | — | — |
| DN | NPS | Face-to-face dimension mm | |||||||||||||
| PN 20(class 150) | PN 50(class 300) | PN 64(class 400) | PN 100(class 600) | PN 150(class 900) | PN 250(class 1500) | PN 420(class 2500) | |||||||||
| Short-pattern | Long-pattern | Short-pattern | Long-pattern | Short-pattern | Long-pattern | Short-pattern | Long-pattern | Short-pattern | Long-pattern | Short-pattern | Long-pattern | Short-pattern | Long-pattern | ||
| 50 | 2 | 19 | 60 | 19 | 60 | 19 | 60 | 19 | 60 | 19 | 70 | 19 | 70 | — | 70 |
| 65 | 21⁄2 | 19 | 67 | 19 | 67 | 19 | 67 | 19 | 67 | 19 | 83 | 19 | 83 | — | 83 |
| 80 | 3 | 19 | 73 | 19 | 73 | 19 | 73 | 19 | 73 | 19 | 83 | 22 | 83 | — | 86 |
| 100 | 4 | 19 | 73 | 19 | 73 | 22 | 79 | 22 | 79 | 22 | 102 | 32 | 102 | — | 105 |
| 150 | 6 | 19 | 98 | 22 | 98 | 25 | 137 | 29 | 137 | 35 | 159 | 44 | 159 | — | 159 |
| 200 | 8 | 29 | 127 | 29 | 127 | 32 | 165 | 38 | 165 | 44 | 206 | 57 | 206 | — | 206 |
| 250 | 10 | 29 | 146 | 38 | 146 | 51 | 213 | 57 | 213 | 57 | 241 | 73 | 248 | — | 250 |
| 300 | 12 | 38 | 181 | 51 | 181 | 57 | 229 | 60 | 229 | — | 292 | — | 305 | — | 305 |
| 350 | 14 | 44 | 184 | 51 | 222 | 64 | 273 | 67 | 273 | — | 356 | — | 356 | — | — |
| 400 | 16 | 51 | 191 | 51 | 232 | 64 | 305 | 73 | 305 | — | 384 | — | 384 | — | — |
| 450 | 18 | 60 | 203 | 76 | 264 | 83 | 362 | 83 | 362 | — | 451 | — | 468 | — | — |
| 500 | 20 | 64 | 219 | 83 | 292 | 89 | 368 | 92 | 368 | — | 451 | — | 533 | — | — |
| 600 | 24 | — | 222 | — | 318 | — | 394 | — | 438 | — | 495 | — | 559 | — | — |
| 750 | 30 | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 900 | 36 | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 1 100 | 42 | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 1 200 | 48 | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 1 400 | 54 | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 1 500 | 60 | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
7.5 Valve operation
The purchaser should specify the method of operation and the maximum pressure differential (MPD) at which the valve is required to be opened by the lever, gearbox or actuator. If not specified, the pressure as determined in accordance with 7.2 for material at 38 °C (100 °F) shall be the MPD. The manufacturer shall provide the following data to the purchaser, if requested:
— flow coefficient Cv or Kv ;
— breakaway thrust or torque for new valve;
— maximum allowable stem thrust or torque on the valve and, if applicable, the maximum allowable input torque to the gearbox;
— number of turns for manually operated valves.
7.6 Pigging
The purchaser shall specify the requirements for piggability of the valves.
NOTE Guidance can be found in Clause D.4.
7.7 Valve ends
7.7.1 Flanged ends
7.7.1.1 General
Flanges shall be furnished with a raised face or ring joint face (raised face or full face). Dimensions, tolerances and finishes, including drilling templates, flange facing, spot facing and back facing, shall be in accordance with
— ASME B16.5 for sizes up to and including DN 600 (NPS 24), except DN 550 (NPS 22),
— MSS SP-44 for DN 550 (NPS 22) and
— ASME B16.47, Series A, for DN 650 (NPS 26) and larger sizes.
If none of the above standards applies, the selection of another design code or standard shall be made by agreement.
The manufacturing method shall ensure flange alignment in accordance with 7.7.1.2, 7.7.1.3 and 7.7.1.4.
7.7.1.2 Offset of aligned flange centrelines — Lateral alignment
For valves up to and including DN 100 (NPS 4), the maximum flange misalignment shall be 2 mm (0.079 in).
For valves larger than DN 100 (NPS 4), the maximum flange misalignment shall be 3 mm (0.118 in).
7.7.1.3 Parallelism of aligned flange faces — Angular alignment
The maximum measured difference between flanges shall be 2,5 mm/m (0.03 in/ft).
7.7.1.4 Total allowable misalignment of bolt holes
For valves up to and including DN 100 (NPS 4), the maximum total allowable mismisalignment shall be no greater than 2 mm (0.079 in) at the bolt holes (see Figure 14).
For valves larger than DN 100 (NPS 4), the maximum total allowable misalignment shall be equivalent to 3 mm (0.118 in) at the bolt holes.
The surface finish of the nut bearing area at the back face of flanged valves shall be parallel to within 1° of the flange face.

Key
1 flange
2 hole in first flange
3 hole in opposite flange for alignment
A bolt-hole misalignment (see 7.7.1.4)
Figure 14 — Bolt-hole misalignment
7.7.2 Welding ends
Welding ends shall conform to ASME B31.4-2006, Figures 434.8.6 (a) (1) and (2) or ASME B31.8-2003, Figures 14 and 15, unless otherwise agreed. In the case of a heavy-wall valve body, the outside profile may be tapered at 30° and then to 45° as illustrated in ASME B16.25-2003, Figure 1. The purchaser shall specify the outside diameter, wall thickness, material grade, SMYS and any special chemistry of the mating pipe, and whether cladding has been applied.
7.7.3 Alternate valve end connections
Other end connections can be specified by the purchaser.
7.8 Pressure relief
The manufacturer shall determine whether fluid can become trapped in the body cavity in the open- and/or closed-valve position.
If fluid trapping is possible, then valves for liquid or condensing service shall be provided with automatic cavity-pressure relief, unless otherwise agreed. Automatic cavity relief arrangements for gas service shall be provided by agreement. Cavity relief, if required, shall prevent the pressure in the cavity from exceeding 1,33 times the valve pressure rating at the specified maximum operating temperature, determined in accordance with 7.2. External cavity relief valves shall be DN 15 (NPS ½) or larger.
If cavity relief valves are required, purchaser may specify provisions to facilitate in service testing.
7.9 Bypasses, drains and vents
Bypass, drain and vent connections and plug entries shall be drilled and threaded unless otherwise specified. The purchaser can specify other types of connections, such as welded or flanged.
WARNING — Threaded connections can be susceptible to crevice corrosion.
Thread profiles shall be tapered unless otherwise agreed. Tapered threads shall be capable of providing a seal and comply with ASME B1.20.1. If the use of parallel threads is specified, the connection shall have a head section for trapping and retaining a sealing member suitable for the specified valve service. Parallel threads shall comply with ISO 228-1. Minimum sizes shall be in accordance with Table 7 or by agreement.
| Nominal size of valve | Thread/pipe size | |
| DN | NPS | mm (in) |
| 15 to 40 | 1/2 to 11/2 | 8 (1/4) |
| 50 to 100 | 2 to 4 | 15 (1/2) |
| 150 to 200 | 6 to 8 | 20 (3/4) |
| >200 | >8 | 25 (1) |
7.10 Injection points
Injection points for sealant, lubrication or flushing shall be provided for seats and/or stem if specified by the purchaser and shall incorporate a check valve and a secondary means of isolation for each injection point.
7.11 Drain, vent and sealant lines
Drain, vent and sealant lines shall be provided if specified and shall be extended by means of rigid pipework, if necessary. The lines shall be fastened to the valve and/ or extensions and terminate close to the stem extension top works, by agreement. Drain and vent lines shall
— have a design pressure not less than the rated pressure of the valve on which they are installed;
— be capable of withstanding the hydrostatic shell test pressure of the valve;
— be designed in accordance with a recognised design code;
— be suitable for blow-down operation, where applicable.
Sealant lines shall have a design pressure not less than the greater of the pipeline valve rated pressure and the injection pressure.
The purchaser should specify the injection pressure or the pipe for use. If not specified by the purchaser, the manufacturer shall advise the maximum injection pressure for the system. The size of the sealant lines shall be by agreement. Prior to assembly, the internal bores of sealant lines shall be clean and free from rust and any foreign particles.
7.12 Drain, vent and sealant valves
Drain and vent block valves shall be provided, if specified, shall have a rated pressure not less than the valve on which they are installed and be suitable for blow-down operation. Block and check valves fitted to sealant injection lines shall be rated for the greater of the pipeline valve rated pressure and the injection pressure defined in 7.11.
7.13 Hand-wheels and wrenches — Levers
Wrenches for valves shall either be of an integral design or consist of a head which fits on the stem and is designed to take an extended handle. The head design shall allow permanent attachment of the extended section if specified by the purchaser. The maximum force required at the hand-wheel or wrench to apply the breakaway torque or thrust shall not exceed 360 N (80 lbf).
Wrenches that are of integral design (not loose) shall not be longer than twice the face-to-face or end-to-end dimension unless otherwise agreed.
NOTE Loose wrenches are not considered part of the valve and are not required to meet the maximum length requirements.
Hand-wheel diameter(s) shall not exceed the face-to-face or end-to-end length of the valve or 1 000 mm, whichever is smaller, unless otherwise agreed. Except for valve sizes DN 40 (NPS 1½) and smaller, spokes shall not extend beyond the perimeter of the hand-wheel unless otherwise agreed. If specified by the purchaser, the hand-wheel of the gearbox input shaft shall be provided with a torque-limiting device, such as a shear pin, to prevent damage to the drive train.
Direction of closing shall be clockwise, unless otherwise specified.
7.14 Locking devices
Valves shall be supplied with locking devices if specified by the purchaser. Locking devices for check valves shall be designed to lock the valve in the open position only.
Locking devices for other types of valve shall be designed to lock the valve in the open and/or closed position.
7.15 Position of the obturator
Except for check valves, the position of the obturator shall not be altered by dynamic forces of the passing flow or in the case of screw operated gate valves by forces generated from internal pressure.
7.16 Position indicators
Valves fitted with manual or powered actuators shall be furnished with a visible indicator to show the open and the closed position of the obturator. For plug and ball valves, the wrench and/or the position indicator shall be in line with the pipeline when the valve is open and transverse when the valve is closed. The design shall be such that the component(s) of the indicator and/or wrench cannot be assembled to falsely indicate the valve position.
Valves without position stops shall have provision for the verification of open and closed alignment with the operator/actuator removed.
7.17 Travel stops
Travel stops shall be provided on the valve and/or operator and they shall locate the position of the obturator in the open and closed position. The travel stops shall not affect the sealing capability of the valve.
7.18 Actuator, operators and stem extensions
7.18.1 General
Actuators can be powered by electric, hydraulic or pneumatic means. The output of the actuator shall not exceed the stress limits of the valve drive train permitted by 7.20.2, unless otherwise agreed.
NOTE Typical quarter-turn valve-to-actuator interfaces are given in ISO 5211 [8].
7.18.2 Misalignment
Misalignment or improper assembly of components shall be prevented by suitable means, such as a dowel pin or fitting bolt, which ensures the correct location of manual or powered operators and stem extension assemblies.
7.18.3 Sealing
Operators, stem extensions and their interfaces shall be sealed to prevent ingress of external contaminants and moisture.
7.18.4 Overpressure protection
Operators and stem extension assemblies shall be provided with a means of preventing pressure build-up in the mechanism resulting from stem or bonnet seal leakage.
7.18.5 Protection of extended stems and shafts in below ground service
Extended stems and shafts in below-ground service shall be protected by an extension casing (housing).
7.19 Lifting
Valves of size DN 200 (NPS 8) and larger shall be provided with lifting points, unless otherwise agreed. The manufacturer shall verify suitability of the lifting points. If the valve manufacturer is responsible for the supply of the valve and operator assembly, the valve manufacturer shall verify the suitability of the lifting points for the complete valve and operator assembly. If the purchaser is responsible for the supply of the operator assembly, the purchaser shall provide adequate information to enable the manufacturer to verify the suitability of the lifting points for the complete assembly.
NOTE Regulatory requirements can specify special design, manufacturing and certification of lifting points.
7.20 Drive trains
7.20.1 Design thrust or torque
The design thrust or torque for all drive train calculations shall be at least two times the breakaway thrust or torque.
NOTE This design factor is to allow for thrust or torque increase in service due to infrequent cycling, low-temperature operation and the adverse effect of debris.
7.20.2 Allowable stresses
Tensile stresses in drive train components, including stem extensions, shall not exceed 67 % of SMYS when delivering the design thrust or torque. Shear, torsion and bearing stresses shall not exceed the limits specified in ASME Code Section VIII, Division 2, Part AD-132, except that design stress intensity values, Sm , shall be 67 % of SMYS. These stress limits do not apply to the components of rolling-element or other proprietary bearings or high bearing strength capable materials that are included in the drive train where manufacturer's recommendations or limits derived from tests and service experience apply. These limits shall be justified in design documents.
The drive train shall be designed such that the weakest component is outside the pressure boundary.
A strength efficiency factor of 0,75 shall be used for fillet welds.
WARNING — If an actuator or operator can deliver a thrust or torque that is greater than the design thrust or torque of the drive train, such a thrust or torque can result in permanent deformation or failure of drive train components.
7.20.3 Allowable deflections
Deflections of the extended drive train shall not prevent the obturator from reaching the fully closed or fully open position.
For all valves, attention shall be paid to deflection and strain. Adherence to the allowable stress limits of design codes alone might not result in a functionally acceptable design. The manufacturer shall demonstrate, by calculation or test, that under loads resulting from design pressure and any defined pipe or external loads, distortion of the obturator or seat does not impair functionality or sealing.
7.21 Stem retention
Valves shall be designed to ensure that the stem does not eject under any internal pressure condition or if the packing gland components and/or valve operator mounting components are removed.
7.22 Fire type-testing
If specified by the purchaser, fire type-testing certification of the design shall be provided. Fire type-testing shall be carried out in accordance with Clause D.5, unless otherwise agreed.
7.23 Anti-static device
Soft-seated valves shall have an anti-static device, unless otherwise agreed. If specified by the purchaser, valves shall be tested in accordance with Clause B.5.
7.24 Design documents
The design shall be documented in a retrievable and reproducible form.
7.25 Design document review
Design documentation shall be reviewed and verified by competent personnel other than the person who performed the original design.
8 Materials
8.1 Material specification
Specifications for metallic pressure-containing and pressure-controlling parts shall be issued by the manufacturer and shall address the following, as a minimum:
— chemical analysis;
— carbon equivalent (if applicable);
— heat treatment;
— mechanical properties including charpy impacts and hardness (if applicable);
— testing;
— certification.
Metallic pressure-containing parts shall be made of materials consistent with the pressure temperature rating as determined in accordance with 7.2. Use of other materials shall be by agreement.
8.2 Service compatibility
All process-wetted parts, metallic and non-metallic, and lubricants shall be suitable for the commissioning fluids and service specified by the purchaser. Metallic materials shall be selected so as to avoid corrosion and galling, which would impair function and/or pressure containing capability. Selection of elastomeric materials for valves intended for hydrocarbon gas service at pressures of PN 100 (class 600) and above shall consider the effect of explosive decompression.
8.3 Forged parts
Each forging shall be hot worked and heat treated to produce uniform grain size and mechanical properties in the finished product.
8.4 Composition limits
The chemical composition of carbon steel pressure-containing and pressure-controlling parts shall be in accordance with the applicable material standards.
The chemical composition of carbon steel welding ends shall meet the following requirements unless otherwise agreed.
— The carbon content shall not exceed 0,23 % by mass.
— The sulfur content shall not exceed 0,035 % by mass.
— The phosphorus content shall not exceed 0,035 % by mass.
— The carbon equivalent, CE, shall not exceed 0,43 %.
The CE shall be calculated in accordance with Equation (2) 4 :
CE = % C + % Mn /6 + (% Cr + % Mo + % V) /5 + (% Ni + % Cu) /15(2)
The chemical composition of other carbon steel parts shall be in accordance with the applicable material standards.
The carbon content of austenitic stainless steel welding ends shall not exceed 0,03 % by mass, except for stabilized material in which case a carbon content of up to 0,08 % by mass is permissible. The chemical composition of other materials shall be established by agreement.
8.5 Toughness test requirements
All carbon, alloy steels and non-austenitic stainless steel for pressure-containing parts in valves shall meet the toughness test requirements of the applicable pipeline design standard. All carbon, alloy steels and non-austenitic stainless steel for pressure-containing parts in valves with a specified design temperature below -29°C ( -20°F ) shall be impact-tested using the Charpy V-notch technique in accordance with ISO 148-1 or ASTM A370.
NOTE Design standards or local requirements can require impact testing for minimum design temperatures higher than -29°C ( -20°F ).
A minimum of one impact test, comprised of a set of three specimens, shall be performed on a representative test bar of each heat of the material in the final heat-treated condition.
Test specimens shall be cut from a separate or attached block taken from the same heat, reduced by forging where applicable, and heat-treated to the same heat treatment, including stress-relieving, as the product materials, except that it is not necessary to retest pressure-containing parts stress-relieved at or below a previous stress-relieving or tempering temperature. The impact test shall be performed at the lowest temperature as defined in the applicable material specifications and pipeline design standard.
Except for material for bolting, impact test results for full-size specimens shall meet the requirements of Table 8. Where the material specification or the pipeline design standard requires impact values higher than those shown in Table 8, the higher values shall apply. Impact test results for bolting material shall meet the requirements of ASTM A320.
| Specified minimum tensile strength MPa | Average of three specimens J | Single specimen J |
| < 586 | 20 | 16 |
| 586 to 689 | 27 | 21 |
| > 689 | 34 | 26 |
6) The symbols used in this equation are not in accordance with the ISO directives for elements used in mathematical equations. However, due to its wide-spread use, a derogation has been granted to retain this equation in its original form.
8.6 Bolting
Bolting material shall be suitable for the specified valve service and pressure rating.
Carbon and low-alloy steel bolting material with a hardness exceeding HRC 34 (HBW 321) shall not be used for valve applications where hydrogen embrittlement can occur, unless otherwise agreed.
NOTE Hydrogen embrittlement can occur in buried pipelines with cathodic protection.
Hardness limits for other bolting materials shall be by agreement.
8.7 Sour service
Materials for pressure-containing and pressure-controlling parts and bolting shall meet the requirements of ISO 15156 (all parts) if sour service is specified by the purchaser.
8.8 Vent and drain connections
Threaded plugs shall be compatible with the valve body material or made from a corrosion resistant material.
9 Welding
9.1 Qualifications
Welding, including repair welding, of pressure-containing and pressure-controlling parts shall be performed in accordance with procedures qualified to ISO 15607, ISO 15609, ISO 15614-1 or ASME Section IX and 9.2 and 9.3 of this International Standard. Welders and welding operators shall be qualified in accordance with ISO 9606-1, ASME Section IX or EN 287-1. NOTE 1 The purchaser, pipeline design standards, material specifications and/or local requirements can specify additional requirements.
The results of all qualification tests shall be documented in a PQR.
PWHT shall be performed in accordance with the relevant material specification.
NOTE 2 Some pipeline welding standards can have more stringent requirements for the essential variables of welding. It can be necessary to provide full weld test rings, in the same heat treatment condition as the finished valve, for weld procedure qualification.
9.2 Impact testing
Qualifications of procedures for welding include repair welding; pressure-containing parts shall meet the toughness test requirements of the applicable pipeline design standard.
As a minimum, impact testing shall be carried out for the qualification of procedures for welding on valves with a design temperature below - 29 °C (- 20 °F).
NOTE Design standards and/or local requirements might require impact testing at minimum design temperatures above -29 °C (-20 °F).
A set of three weld-metal impact specimens shall be taken from the weld metal (WM) at the location shown in Figure 15. The specimens shall be oriented with the notch perpendicular to the surface of the material. A set of three impact specimens shall be taken from the heat-affected zone (HAZ) at the location shown in Figure 16. The notch shall be placed perpendicularly to the material surface at a location resulting in a maximum amount of HAZ material located in the resulting fracture. HAZ tests shall be conducted for each of the materials being joined, when the base materials being joined are of a different P-number and/or Group-number in accordance with ISO 9606-1, ISO 15607, ISO 15609, ISO 15614-1 or ASME Section IX when one or both of the base materials being joined are not listed in the P-number grouping.
Impact testing shall be performed in accordance with ISO 148-1 or ASTM A370 using the Charpy V-notch technique. Specimens shall be etched to determine the location of the weld and HAZ. The impact test temperature for welds and heat-affected zones shall be at or below the minimum design temperature specified for the valve.
Impact test results for full-size specimens shall meet the requirements of Table 8. If the material specification or the pipeline design standard requires higher impact values than those shown in Table 8, the higher values shall apply.
9.3 Hardness testing
Hardness testing shall be carried out as part of the welding procedure qualification on pressure-containing and pressure-controlling parts in valves required to meet ISO 15156 (all parts). Hardness surveys shall be performed on BM, WM and HAZ in accordance with the requirements of ISO 15156-2. The hardness method used shall be Vickers HV
5 or HV
10
.
NOTE For existing qualification, other hardness measurement methods (such as HRC or HRB) are acceptable by agreement.
9.4 Repair
Minor defects may be removed by grinding provided there is a smooth transition between the ground area and the original contour and the minimum wall thickness requirements are not affected.
Repair of defects shall be performed in accordance with a documented procedure specifying requirements for defect removal, welding, heat treatment, NDE and reporting as applicable. Repairs of fabrication welds shall be limited to 30 % of the weld length for partial-penetration repairs or 20 % of the weld length for full-penetration repairs, except the minimum length of any weld repair shall be 50 mm. The heat treatment (if applicable) of weld repairs shall be in accordance with the applicable material standard.
Weld repair of forgings and plates to correct manufacturing defects shall be by agreement. Weld repair of castings shall be in accordance with the applicable material standard.

Key
1 weld metal
2 heat-affected zone
3 base metal

Key
1 weld metal
2 heat-affected zone
3 base metal
Figure 16 — Charpy V-notch heat-affected zone (HAZ) specimen location
10 Quality control
10.1 NDE requirements
Any purchaser specified NDE requirements shall be selected from the list in accordance with Annex A. Final NDE activities shall be conducted after heat treatment unless otherwise agreed.
10.2 Measuring and test equipment
10.2.1 General
Measuring and test equipment shall be identified, controlled and calibrated at intervals specified in the manufacturer's instructions.
10.2.2 Dimension-measuring equipment
Dimension-measuring equipment shall be controlled and calibrated in accordance with methods specified in documented procedures.
10.2.3 Pressure-measuring devices
10.2.3.1 Type and accuracy
Test pressure measuring devices shall be either pressure gauges or pressure transducers that are accurate to within ± 2,0 % of the full-scale reading.
10.2.3.2 Gauge range
Pressure measurements shall be made between 25 % and 75 % of the full pressure range of the measuring device.
10.2.3.3 Calibration procedure
Pressure-measuring devices shall be periodically recalibrated with a master pressure-measuring device or a dead-weight tester at 25%, 50% and 75% of the full pressure scale.
10.2.4 Temperature-measuring devices
Temperature-measuring devices shall be capable of indicating and recording temperature fluctuations of 5 °C (8 °F).
10.3 Qualification of inspection and test personnel
10.3.1 NDE personnel
NDE personnel shall be qualified in accordance with the requirements specified in ISO 9712 or ASNT SNT-TC-1A.
Personnel performing visual examinations shall have passed an annual eye examination in accordance with ISO 9712 or ASNT SNT-TC-1A within the previous twelve months.
10.3.2 Welding inspectors
Personnel performing visual inspection of welding operations and completed welds shall be qualified and certified to the requirements of AWS QC1, or equivalent, or a manufacturer's documented training programme.
10.4 NDE of repairs
After defect removal, the excavated area shall be examined by magnetic-particle (MT) or liquid-penetrant (PT) methods in accordance with Annex A. Repair welds on pressure-containing parts shall be examined using the same NDE method that was used to detect the defect with a minimum of MT or PT. Acceptance criteria shall be as specified in Annex A for the appropriate product form. The final NDE activities shall be conducted after post weld heat treatment unless otherwise agreed. The NDE requirements specified by the purchaser in 10.1 shall also apply to repair welding.
10.5 Weld end NDE
If the purchaser specifies that weld ends be subjected to volumetric or surface NDE, the examination and acceptance criteria shall be in accordance with Clause A.22.
10.6 Visual inspection of castings
All castings as a minimum shall be visually inspected in accordance with MSS SP-55.
11 Pressure testing
11.1 General
Each valve shall be tested prior to shipment. The purchaser shall specify which particular supplementary tests in Annex B shall be performed.
Testing shall be performed in the sequence detailed in 11.2 to 11.5. Pressure testing shall be carried out before coating of the valves.
If the valve has been previously tested in accordance with this International Standard, subsequent repeat testing may be performed without removal of the valve external coating.
Test fluid shall be fresh water or, by agreement, light-weight oil having a viscosity not exceeding that of water. Water shall contain a corrosion inhibitor and, by agreement, antifreeze. The chloride content of test water in contact with austenitic and duplex stainless steel wetted components of valves shall not exceed 30 μ g/g (30 ppm by mass). Valves shall be tested with the seating and sealing surfaces free from sealant except where the sealant is the primary means of sealing. A secondary sealant system, if provided, shall not be used before or during tests.
Tests specified with the valve half-open may also be performed with the valve fully open, provided the body cavity is simultaneously filled and pressurized through a cavity connection. If valve-body connections are not available for direct monitoring, methods for monitoring pressures and/or leakage shall be determined.
Supply pressure shall be stabilized prior to the start of pressure testing and shall be held for the minimum test durations listed in Tables 9, 10 and 11.
Pressure testing shall be performed in accordance with documented procedures.
11.2 Stem backseat test
Testing of the backseat shall commence with the packing gland loose. Self-energized packing or seals shall be removed unless a test port is provided for this test.
The valves shall be filled with the ends closed off and the obturator in the partially open position until leakage of the test fluid around the stem is observed. The backseat shall then be closed and a minimum pressure of 1,1 times the pressure rating determined in accordance with 7.2 for material at 38 °C (100 °F) applied for the duration specified in Table 9. Monitoring for leakage shall be through a test access port or by monitoring leakage around the loosened packing.
NOTE This test is performed prior to hydrostatic shell test.
WARNING — Appropriate safety precautions shall be taken.
| Valve size | Test duration | |
| DN | NPS | min |
| ≤100 | ≤4 | 2 |
| ≥150 | ≥6 | 5 |
11.3 Hydrostatic shell test
Valve ends shall be closed off and the obturator placed in the partially open position during the test. If specified by the purchaser, the method of closing the ends shall permit the transmission of the full-pressure force acting on the end blanks to the valve body. If present, external relief valves shall be removed and their connections plugged. The test pressure shall be 1,5 or more times the pressure rating determined in accordance with 7.2 for material at 38 °C (100 °F). The duration shall not be less than that specified in Table 10.
| Valve size | Test duration | |
| DN | NPS | min |
| 15 to 100 | 1/2 to 4 | 2 |
| 150 to 250 | 6 to 10 | 5 |
| 300 to 450 | 12 to 18 | 15 |
| ≥ 500 | ≥ 20 | 30 |
After hydrostatic shell testing, external relief valves shall be fitted to the valve. The connection to the valve body shall be tested at 95 % of the set pressure of the relief valve for 2 min for valve sizes up to and including DN 100 (NPS 4), and 5 min for valve sizes DN 150 (NPS 6) and larger. The relief-valve connection shall be free of visible leakage during this period. The external relief valves shall be set to relieve at the specified pressure and tested in accordance with 11.4.5.
11.4 Hydrostatic seat test
11.4.1 Preparation
Lubricants or sealants shall be removed from seats and obturator sealing surfaces except where the lubricant or sealant is the primary means of sealing. Assembly lubricants for metal-to-metal contact surfaces may be used by agreement.
11.4.2 Test pressure and duration
The test pressure for all seat tests shall not be less than 1,1 times the pressure rating determined in accordance with 7.2 for material at 38 °C (100 °F). The test duration shall be in accordance with Table 11.
| Valve size | Test durationmin | |
| DN | NPS | |
| 15 to 100 | 1/2 to 4 | 2 |
| ≥ 150 | ≥ 6 | 5 |
11.4.3 Acceptance criteria
NOTE Special application can require that the leakage rate be less than ISO 5208:1993, Rate D.
11.4.4 Seat test procedures for block valves
11.4.4.1 Uni-directional
With the valve half-open, the valve and its cavity shall be completely filled with test fluid. The valve shall then be closed and the test pressure applied to the appropriate end of the valve.
Leakage from the upstream seat shall be monitored via the valve body cavity vent or drain connection, where provided. For valves without body cavity or drain connection, or downstream seated valves, seat leakage shall be monitored at the respective downstream end of the valve (the valve end downstream of the pressurized test fluid).
11.4.4.2 Bi-directional
With the valve half-open, the valve and its cavity shall be completely filled with test fluid. The valve shall then be closed and the test pressure applied successively to both ends of the valve.
Seat leakage shall be monitored from each seat via the valve body cavity vent or drain connection, where provided. For valves without a body-cavity vent or drain connection, seat leakage shall be monitored from the respective downstream end of the valve.
11.4.4.3 Additional seat testing
If the purchaser specifies the functionality for the valve to be that of double-block-and-bleed (DBB) valves, the test described in Clause B.10 shall be performed.
If the purchaser specifies the functionality for the valve to be that of double-isolation-and-bleed (DIB-1), both seats bi-directional, the test described in Clause B.11 shall be performed.
If the purchaser specifies the functionality for the valve to be that of DIB-2, one seat uni-directional and one seat bi-directional, the test described in Clause B.12 shall be performed.
11.4.4.4 Check valves
The pressure shall be applied in the direction of the required flow blockage.
11.4.5 Test of cavity relief valve
If provided, the external relief valve shall be set and certified to relieve at the specified pressure either by the relief-valve supplier or the valve manufacturer. The set pressure of relief valves shall be between 1,1 and 1,33 times the valve pressure rating determined in accordance with 7.2 for material at 38 °C (100 °F).
11.4.6 Installation of body connections after testing
Parts, such as vent or drain plug(s) and cavity-relief valves, shall be fitted, on completion of testing, in accordance with documented procedures.
11.4.7 Alternative seat test
High-pressure gas seat testing in accordance with Clause B.4 can be performed in lieu of the hydrostatic seat test by agreement.
11.5 Testing of drain, vent and sealant injection lines
If provided, drain and vent lines shall be subject to a hydrostatic test with the valve in accordance with 11.3. If testing with the valve is not practical, these lines may be tested separately, provided the final assembly connection is subjected to the hydrostatic test in 11.3 or, by agreement, a pneumatic pressure test as listed in B.3.3. The test pressure for sealant injection lines shall be by agreement.
11.6 Draining
Upon completion of tests, valves shall be drained of test fluids, dried and, where applicable, lubricated before shipment.
12 Coating
All non-corrosion-resistant valves shall be coated externally in accordance with the manufacturer's standards, unless otherwise agreed.
Corrosion-resistant valves shall not be coated unless otherwise agreed.
Flange faces, weld bevel ends and exposed stems shall not be coated.
Parts and equipment that have bare metallic surfaces shall be protected with a rust preventative that can provide protection at temperatures up to 50 °C (122 °F).
13 Marking
Valves shall be marked in accordance with the requirements of Table 12.
Body/cover/closure stamping shall be performed using a low-stress die-stamp, rounded “V” or Dot Face type. Each valve shall be provided with an austenitic stainless steel nameplate securely affixed and so located that it is easily accessible. The marking on the nameplate shall be visually legible. On valves whose size or shape limits the body markings, they may be omitted in the following order:
a) manufacturer's name or trademark;
b) material;
c) rating;
d) size.
The nameplate and serial number may be omitted for valves smaller than DN 50 (NPS 2), by agreement.
NOTE The purchaser can specify requirements for the marking of valve components.
For valves with one seat uni-directional and one seat bi-directional, the directions of both seats shall be specified on a separate identification plate as illustrated in Figure 17. In Figure 17, one symbol indicates the bi-directional seat and the other symbol indicates the uni-directional seat. An example of valve marking is given in Annex E.

| No. | Marking | Location |
| 1 | manufacturer's name or trademark | both body and nameplate |
| 2 | pressure class | both body and nameplate |
| 3 | pressure/temperature rating: a) maximum operating pressure at maximum operating temperature b) maximum operating pressure at minimum operating temperature | nameplate |
| 4 | face-to-face/end-to-end dimensions (7.4) | nameplate |
| 5 | body material designation a: material symbol, e.g. AISI, ASME, ASTM or ISO | both body and nameplate; melt identification (e.g. cast or heat number) on body only |
| 6 | bonnet/cover material designation: material symbol e.g. AISI, ASME, ASTM, ISO | bonnet/cover [including melt identification (e.g. heat number)] |
| 7 | trim identification b: symbols indicating material of stem and sealing faces of closure members if different from that of body | nameplate |
| 8 | nominal valve size a) full-opening valves: nominal valve size b) reduced-opening valves: shall be marked as specified in 7.3 | body or nameplate or both (where practicable) |
| 9 | ring joint groove number | valve flange edge |
| 10 | SMYS (units) of valve ends, where applicable | body weld bevel ends |
| 11 | flow direction (for check valves only) | body |
| 12 | seat sealing direction (valves with preferred direction only) | separate identification plate on valve body |
| 13 | seat test per Clauses B.10, B.11, B.12 for DBB, DIB-1 or DIB-2, respectively (where applicable) | nameplate |
| 14 | unique serial number | both body and nameplate |
| 15 | date of manufacture (month and year) | nameplate |
| 16 | ISO 14313 c | nameplate |
| a When the body is fabricated of more than one type of steel, the end-connection material governs the marking. b MSS SP-25 gives guidance on marking. c For identical national adoptions of this International Standard, other nationally recognized designations may be marked in addition to those given in ISO 14313, e.g. ISO 14313/API Spec 6D. | ||
14 Preparation for shipment
Flanged and welding ends shall be blanked off to protect the gasket surfaces, welding ends and valve internals during shipment.
Protective covers shall be made of wood, wood fibre, plastic or metal and shall be securely attached to the valve ends by bolting, steel straps, steel clips or suitable friction-locking devices. The design of the covers shall prevent the valves from being installed unless the covers have been removed. Plug, ball and reverse-acting through-conduit gate valves shall be shipped in the fully open position, unless fitted with a fail-to-close actuator.
Other gate valve types shall be shipped with the gate in the fully closed position.
Check valves DN 200 (NPS 8) and larger shall be shipped with the disc secured or supported during transport. A warning label shall be attached to the protective cover with instructions to remove, prior to installation, material from inside the valve that secures or supports the disc. Valves shipped with stem extensions and without an operating mechanism shall have the annular space closed and the stem extension secured to the outer housing.
15 Documentation
The documentation listed below shall be retained by the manufacturer for a minimum of ten years following the date of manufacture:
a) design documentation;
b) weld procedure specification (WPS);
c) weld procedure qualification record (PQR);
d) welder performance qualification (WPQ);
e) qualification records of NDE personnel;
f) records of test equipment calibration;
g) for valves DN 50 (NPS 2) and larger:
1) material test report for body, bonnet/cover(s) and end-connector(s)/closure(s) traceable to the unique valve serial number;
2) serial number;
3) pressure test results;
h) for sour service valves, certificate of compliance to ISO 15156 (all parts).
NOTE Purchaser or regulatory requirements can specify a longer record retention period.
The documentation shall be provided by the manufacturer in legible, retrievable and reproducible form and free of damage.
The purchaser can specify supplementary documentation in accordance with Annex C.
API Specification 6D / ISO 14313
Annex A (normative)
A.1 General
This annex specifies the requirements for non-destructive examination (NDE) that shall be performed by the manufacturer if specified by the purchaser.
A.2 Radiographic testing (RT) of castings on 100 % of critical areas
Examination shall be carried out in accordance with ASME B16.34-2004, Appendix-I.
Acceptance shall be in accordance with ASME B16.34-2004, Appendix-I.
A.3 Radiographic testing (RT) of castings on 100 % of accessible areas
Examination shall be carried out in accordance with ASME B16.34-2004, Appendix-I.
Acceptance shall be in accordance with ASME B16.34-2004, Appendix-I.
A.4 Ultrasonic testing (UT) of castings on 100 % of critical areas
Examination shall be carried out in accordance with ASME B16.34-2004, Appendix-IV.
Acceptance shall be in accordance with ASME B16.34-2004, Appendix-IV.
A.5 Ultrasonic testing (UT) of castings on 100 % of accessible areas
Examination shall be carried out in accordance with ASME B16.34-2004, Appendix-IV.
Acceptance shall be in accordance with ASME B16.34-2004, Appendix-IV.
A.6 Magnetic-particle testing (MT) of castings on 100 % of surface area
Examination shall be carried out in accordance with ASME Boiler and Pressure Vessel Code, Section V, Article 7.
Acceptance shall be in accordance with ASME Boiler and Pressure Vessel Code, Section VIII, Division 1, Appendix 6, except that relevant indications (rounded and linear) of less than 5 mm are acceptable.
A.7 Penetrant testing (PT) of castings on 100 % of surface area
Examination shall be carried out in accordance with ASME Boiler and Pressure Vessel Code, Section V, Article 6. Acceptance shall be in accordance with ASME Boiler and Pressure Vessel Code, Section VIII, Division 1, Appendix 8, except that relevant indications (rounded and linear) of less than 5 mm are acceptable.
A.8 Ultrasonic testing (UT) of forgings and plate on 100 % of surface area
Examination shall be carried out in accordance with ASTM A388, ASTM A435 or ASTM A577, as applicable.
Acceptance shall be in accordance with ASTM A388, ASTM A435 or ASTM A577, as applicable.
A.9 Magnetic-particle testing (MT) of forgings on 100 % of surface area
Examination shall be carried out in accordance with ASME Boiler and Pressure Vessel Code, Section V, Article 7.
Acceptance shall be in accordance with ASME Boiler and Pressure Vessel Code, Section VIII, Division 1 Appendix 6.
A.10 Penetrant testing (PT) of forgings on 100 % of surface area
Examination shall be carried out in accordance with ASME Boiler and Pressure Vessel Code, Section V, Article 6.
Acceptance shall be in accordance with ASME Boiler and Pressure Vessel Code, Section VIII, Division 1, Appendix 8.
A.11 Radiographic testing (RT) of weldments on 100 % of weld
Examination shall be carried out in accordance with ASME Boiler and Pressure Vessel Code, Section V, Article 2.
Acceptance shall be in accordance with ASME Boiler and Pressure Vessel Code, Section VIII, Division 1, UW-51, for linear indications and ASME Boiler and Pressure Vessel Code, Section VIII, Division 1, Appendix 4, for rounded indications.
A.12 Ultrasonic testing (UT) of full-penetration welds on 100 % of weld
Examination shall be carried out in accordance with ASME Boiler and Pressure Vessel Code, Section V, Article 4.
Acceptance shall be in accordance with ASME Boiler and Pressure Vessel Code, Section VIII, Division 1, Appendix 12.
A.13 Magnetic-particle testing (MT) of welds on 100 % of weld surface area
Examination shall be carried out in accordance with ASME Boiler and Pressure Vessel Code, Section V, Article 7.
Acceptance shall be in accordance with ASME Boiler and Pressure Vessel Code, Section VIII, Division 1, Appendix 6 or ISO 23278.
A.14 Penetrant testing (PT) of welds on 100 % of weld surface area
Examination shall be carried out in accordance with ASME Boiler and Pressure Vessel Code, Section V, Article 6.
Acceptance shall be in accordance with ASME Boiler and Pressure Vessel Code, Section VIII, Division 1, Appendix 8 or ISO 23277.
A.15 Magnetic-particle testing (MT) of bolting
Examination shall be carried out in accordance with ASME Boiler and Pressure Vessel Code, Section V, Article 7.
Acceptance shall be in accordance with ASME Boiler and Pressure Vessel Code, Section VIII, Division 1, Appendix 6.
A.16 Penetrant testing (PT) of bolting
Examination shall be carried out in accordance with ASME Boiler and Pressure Vessel Code, Section V, Article 6.
Acceptance shall be in accordance with ASME Boiler and Pressure Vessel Code, Section VIII, Division 1, Appendix 8.
A.17 Magnetic-particle testing (MT) on 100 % of machined surfaces
Examination shall be carried out in accordance with ASME Boiler and Pressure Vessel Code, Section V, Article 7.
Acceptance shall be in accordance with ASME Boiler and Pressure Vessel Code, Section VIII, Division 1, Appendix 6.
A.18 Penetrant testing (PT) on 100 % of machined surfaces
Examination shall be carried out in accordance with ASME Boiler and Pressure Vessel Code, Section V, Article 6.
Acceptance shall be in accordance with ASME Boiler and Pressure Vessel Code, Section VIII, Division 1, Appendix 8.
A.19 Penetrant testing (PT) of weld bevels of welding ends
Examination shall be carried out in accordance with ASME Boiler and Pressure Vessel Code, Section V, Article 6.
Acceptance shall be in accordance with ASME Boiler and Pressure Vessel Code, Section VIII, Division 1, Appendix 8.
A.20 Magnetic-particle testing (MT) of weld bevels of welding ends
Examination shall be carried out in accordance with ASME Boiler and Pressure Vessel Code, Section V, Article 7.
Acceptance shall be in accordance with ASME Boiler and Pressure Vessel Code, Section VIII, Division 1, Appendix 6.
A.21 Penetrant testing (PT) of weld overlay
Examination shall be carried out in accordance with ASME Boiler and Pressure Vessel Code, Section V, Article 6.
Acceptance criteria for non-machined overlay shall be in accordance with ASME Boiler and Pressure Vessel Code, Section VIII, Division 1, Appendix 8, except that relevant indications (rounded and linear) of less than 5 mm are acceptable. Acceptance criteria for machined overlay shall be in accordance with ASME Boiler and Pressure Vessel Code, Section VIII, Division 1, Appendix 8, except that there shall be no indications in the seal areas.
A.22 NDE volumetric and surface for weld ends
Volumetric NDE examination of welding ends (see Clauses A.2, A.4 or A.8) shall be performed for a minimum length equal to 1,5 times the mating pipe wall thickness or 50 mm, whichever is greater. Surface NDE shall be performed on the machined ends of the valve-weld bevel per Clauses A.19 or A.20.
B.1 General
This annex specifies requirements for supplementary testing, which shall be performed by the manufacturer if specified by the purchaser. The frequency of testing shall also be specified by the purchaser, if not defined in this annex.
B.2 Hydrostatic testing
By agreement, hydrostatic testing may be performed at pressures higher than specified in 11.3 and 11.4 and/or for periods longer than specified in Tables 9, 10 or 11.
B.3 Low-pressure gas seat testing
B.3.1 Acceptance
The acceptable leakage rate for low-pressure gas seat testing shall be
— ISO 5208:1993, Rate D, for metal-seated valves.
B.3.2 Type I
The seat test specified in 11.4 shall be repeated at a test pressure between 0,05 MPa (0.5 bar; 7.3 psi) and 0,10 MPa (1.0 bar; 14.5 psi) using air or nitrogen as the test medium.
B.3.3 Type II
The seat test specified in 11.4 shall be repeated at a test pressure of 0,55 MPa ± 00,7 MPa (5.5 bar ± 0.7 bar; 80.8 psi ± 10.3 psi) using air or nitrogen as the test medium.
B.4 High-pressure gas testing
B.4.1 General
High-pressure gas testing shall be performed after hydrostatic shell testing.
WARNING — High-pressure gas testing involves potential hazards. Appropriate safety precautions should be taken.
B.4.2 Seat testing
The seat tests specified in 11.2 and 11.4 shall be replaced with a high-pressure seat test using an inert gas as the test medium. The test pressure and duration shall be as specified in 11.2 and 11.4.
B.4.3 Shell testing
Valves designated by the purchaser shall have a high-pressure gas shell test performed using inert gas as the test medium. The minimum test pressure shall be 1,1 times the pressure rating determined in accordance with 7.2 for the material at 38 °C (100 °F). The test duration shall be in accordance with Table B.1.
| Valve size | Test duration | |
| DN | NPS | min |
| 15 to 450 | 1/2 to 18 | 15 |
| ≥ 500 | ≥ 20 | 30 |
B.5 Anti-static testing
The electrical resistance between the obturator and the valve body and between the stem/shaft and the valve body shall be measured using a direct-current power source not exceeding 12 V. The resistance shall be measured on dry valves before pressure testing and shall not exceed 10 Ω. At least 5 % of the valves in the order shall be tested.
B.6 Torque/thrust functional testing
The maximum torque or thrust required to operate ball, gate or plug valves shall be measured at the pressure specified by the purchaser for the following valve operations:
a) open to closed with the bore pressurized and the cavity at atmospheric pressure;
b) closed to open with both sides of the obturator pressurized and the cavity at atmospheric pressure;
c) closed to open with one side of the obturator pressurized and the cavity at atmospheric pressure;
d) as in (c) but with the other side of the obturator pressurized.
Torque or thrust values shall be measured with seats free of sealant except where the sealant is the primary means of sealing. If necessary for assembly, a lubricant with a viscosity not exceeding that of SAE 10W motor oil or equivalent may be used. Thrust and torque testing shall be performed following hydrostatic shell testing and, if specified, prior to any low-pressure gas seat testing.
The measured torque or thrust results shall be recorded and shall not exceed the manufacturer's documented breakaway torque/thrust.
B.7 Drive train strength test
B.7.1 General
The test torque shall be the greater of
a) twice the manufacturer's predicted break-away torque/thrust, or
b) twice the measured break-away torque/thrust.
The test torque shall be applied with obturator blocked for a minimum time of 1 min.
NOTE For gate valves, the thrust can be tensile or compressive, whichever is the most stringent condition.
B.7.2 Acceptance criteria
The test shall not cause any permanent visible deformation of the drive train.
For ball and plug valves, the total torsional deflection of the extended drive train when delivering the design torque shall not exceed the overlap contact angle between the seat and obturator.
B.8 Cavity relief testing
B.8.1 Frequency
Each valve shall be tested.
Cavity relief testing is not required if protection of the cavity against over-pressure is ensured, for both the open and the closed position, by a hole in the obturator or around the seat seal.
B.8.2 Trunnion-mounted ball valves and through-conduit gate valves with internal-relieving seats
The procedure for cavity-relief testing of trunnion-mounted ball valves and through-conduit gate valves with internal-relieving seats shall be as follows.
a) Fill the valve in the half-open position with water.
b) Close the valve and allow water to overflow from the test connection at each end of the valve.
c) Apply pressure to the valve cavity until one seat relieves the cavity pressure into the valve end; record this relief pressure.
d) For valve types with second-seat relief, continue to increase the pressure to the cavity until the second seat relieves; record the relief pressure of the second seat. Failure to relieve at a pressure less than 1,33 times the valve pressure rating shall be cause for rejection.
B.8.3 Floating-ball valves
The procedure for cavity-relief testing of floating-ball valves shall be as follows.
a) With the valve half-open, pressurize the valve to 1,33 times the valve pressure rating specified in 7.2 for the material at 38 °C (100 °F).
b) Close the valve and vent each end to atmospheric pressure.
c) Open the valve to the half-open position and monitor for the release of test medium trapped in the cavity. Evidence of trapped pressurizing medium in the cavity shall be cause for rejection.
B.9 Hydrogen-induced cracking test
Process-wetted and pressure-containing parts that are manufactured, fabricated or formed from plate shall be resistant to hydrogen-induced cracking (HIC). This shall be demonstrated by successful HIC testing in accordance with NACE TM0284, except that the test solution shall comply with NACE TM0177. HIC acceptance criteria, such as the crack-sensitivity ratio (CSR), crack-length ratio (CLR) and crack-thickness ratio (CTR), shall be specified by the purchaser.
B.10 Double-block-and-bleed (DBB) valves
With the valve half-open, the valve and its cavity shall be completely filled with test fluid. The valve shall then be closed and the valve body vent valve opened to allow excess test fluid to overflow from the valve-cavity test connection. The test pressure shall be applied simultaneously from both valve ends. Seat tightness shall be monitored via overflow through the valve cavity connection.
B.11 Double isolation and bleed DIB-1 (both seats bi-directional)
Each seat shall be tested in both directions.
Cavity-relief valves shall be removed if fitted. The valve and cavity shall be filled with test fluid, with the valve half-open, until the test fluid overflows through the cavity relief connection. To test for seat leakage in the direction of the cavity, the valve shall be closed. The test pressure shall be applied successively to each valve end to test each seat separately from the upstream side. Leakage shall be monitored via the valve cavity pressure relief connection.
Thereafter, each seat shall be tested as a downstream seat. Both ends of the valve shall be drained and the valve cavity filled with test fluid. Pressure shall then be applied whilst monitoring leakage through each seat at both ends of the valve. Some valve designs can require the balancing of the upstream and valve cavity pressure during the downstream seat test.
B.12 Double isolation and bleed DIB-2 (one seat uni-directional and one seat bi-directional)
The bi-directional seat shall be tested in both directions.
Cavity-relief valves shall be removed if fitted. The valve and cavity shall be filled with test fluid, with the valve half-open, until the test fluid overflows through the cavity relief connection.
To test for seat leakage in the direction of the cavity, the valve shall be closed. The test pressure shall be applied successively to each valve end to test each seat separately from the upstream side. Leakage shall be monitored via the valve cavity pressure relief connection. To test the bi-directional seat from the cavity test, pressure shall be applied simultaneously to the valve cavity and upstream end. Monitor leakage at the downstream end of the valve.
The purchaser may select supplementary documentation to be provided from the list below:
a) NDE records;
b) WPS;
c) PQR;
d) WPQ;
e) for sour service valves, certificate of compliance to ISO 15156 (all parts);
f) hardness test report on pressure-containing parts;
g) hardness test report on pressure-controlling parts;
h) certificate of conformance to this International Standard;
i) heat treatment certification records (e. g. charts);
j) design calculations for pressure-containing parts and/or the drive train;
k) design calculations for pressure-controlling parts;
I) pressure test report, (including pressure, test duration, test medium and acceptance criteria);
m) NDE personnel qualification records;
n) coating/plating certification;
o) NDE procedures;
p) calibration records (purchaser to identify requirements for equipment when ordering);
q) fire type-test certificate;
r) material inspection certificates in accordance with ISO 10474 or EN 10204, as applicable (the purchaser shall specify the type of certification, and for which parts, when ordering);
s) design verification by certification body/agency;
t) type approval by certification body/agency;
u) installation, operation and maintenance instructions/manuals;
v) general arrangements drawings;
w) cross-sectional drawings with parts and materials list;
x) flow coefficient, Cv or Kv ;
y) current quality management system certificate.
API Specification 6D / ISO 14313
D.1 General
This annex provides guidelines to assist the purchaser with valve type selection and specification of specific requirements when ordering valves.
D.2 Field testing
Pressures during the testing of installed valves should not exceed the pressure rating of the valve by more than 50 % when testing with the valve partially open or by more than 10 % when testing against a closed valve. Tests specified with the valve half-open may also be performed with the valve fully open, provided the body cavity is simultaneously filled and pressurized through a cavity connection.
NOTE The maximum test pressure for valves fitted with an external pressure relief can be lower (see 7.8).
D.3 Pressure relief
Certain valve designs trap pressure in the valve body cavity when the valve is in the fully open and/or closed position. High internal pressures can result from the thermal expansion of the fluid trapped in these confined areas. If the valve has no self-relieving design provision, pressure-relief fittings shall be fitted in the valve body in accordance with 7.8.
D.4 Pigging
The purchaser should examine the valve design for piggability when ordering valves for use in pipelines requiring pigging. NOTE 1 Venturi or reduced-bore valves are not suitable for most pigging operations, including intelligent pigging, but can allow the passage of foam pigs.
NOTE 2 A valve in which the drive member or the obturator obstructs the bore in the otherwise fully open position (e.g. a dual-plate check valve) is not piggable.
NOTE 3 Certain full-opening valves with pockets can allow bypass of fluid around a short pig or sphere.
D.5 Fire type-testing
The fire-resistance design of valves shall be qualified by fire type-testing in accordance with ISO 10497.
Fire resistance designs already qualified to ISO 10497, API 6FA, API 6FC, API 6FD or API 607 are also acceptable.
D.6 Additional testing
The purchaser shall specify any additional test requirements not covered by this International Standard.
D.7 Valve data sheet
The valve data sheet in Table D.1 can be used to assist with the specification of valves for ordering.
D.8 Information to be provided
Table D.2 provides a list of information that it is necessary for the purchaser and or manufacturer to provide.
Table D.1 — Valve data sheet
Materials of construction ____ Valve location and function ____
Nominal valve size ____ Maximum operating pressure ____
Maximum field test pressure (see Clause D.2) ____ Valve pressure class ____
Maximum service temperature ____ Minimum service temperature ____
Liquid or gas service ____ Flow medium composition ____
Special flow requirements: Blow down, solids, pigs, etc. ____ Valve
Type of valve: ____ Gate ____ Plug ____ Ball ____ Check ____ Design type ____
Full round opening required? ____ Minimum bore ____
End connections
Upstream pipe: OD ____ ID ____ Material ____ Flanged end? Yes ____ No ____
Plain raised face or ring joint? ____ If ring joint, flat or raised face? ____
Size and pressure class, as per ASME B16.5 or MSS SP-44 ____ or ASME B16.47, Series A ____ Ring gasket or other gasket type and size ____
Note Gaskets are not furnished as a part of the valve.
Welding end? Yes ____ No ____
Attach specifications for welding-end configuration.
Special flanges or mechanical joints? ____ Downstream pipe: OD ____ ID ____ Material ____
Flanged end? Yes ____ No ____
Plain raised face or ring joint? ____ If ring joint, flat or raised face? ____
Size and pressure class, as per ASME B16.5 or MSS SP-44 ____ or ASME B16.47, Series A ____ Ring gasket or other gasket type and size ____
Note: Gaskets are not furnished as a part of the valve.
Welding end? Yes ____ No ____
Attach specifications for welding-end configuration.
Special flanges or mechanical joints? ____
Length: Any special requirements for end-to-end or face-to-face dimensions? ____
API Specification 6D / ISO 14313
Table D.1 (continued)
| Clause/subclause | Information | Providera |
| 6.2.2 | Reduced bore sizes other than those shown in tables | P |
| 6.2.2 | Obturator size for non circular openings | A |
| 6.2.2 | Obturator openings in reduced bore valves above DN 600 | A |
| 7.1 | Pressure vessel design | A |
| 7.2 | Intermediate design pressure and temperatures | P |
| 7.2 | Minimum design temperature | P |
| 7.4 | Face-to-face or end-to-end dimension | A |
| 7.4 | Tolerances other than those listed | A |
| 7.5 | Advise MPD | P |
| 7.5 | Valve operation data, torque/thrust, Cv, Kv or number-of-turns data | M-P |
| 7.6 | Requirements for piggability | P |
| 7.7.1 | Alternate standard for flanges | A |
| 7.7.2 | Weld bevels | A |
| 7.7.2 | Mating pipe data | P |
| 7.7.3 | Other end connections | P |
| 7.8 | Determination of whether fluid can become trapped in valve cavities | M |
| 7.8 | Pressure relief, if not required for liquid or condensing service | A |
| 7.8 | Pressure relief, if required for gas service | A |
| 7.8 | Requirements for in-service testing | P |
| 7.9 | Alternative vent/drain connections | P |
| 7.9 | Thread profiles | A |
| 7.9 | Connection sizes | A |
| 7.10 | Sealant injection | P |
| 7.11 | Requirement for extended drain, vent or injection points | P |
| 7.11 | Securing of drain, vent and sealant lines | A |
| 7.11 | Design pressure and size, etc., of extended drain, vent and sealant lines | P |
| 7.11 | Maximum injection pressure for extended injection lines, in absence of purchaser specification | M |
| 7.11 | Size of sealant lines | A |
| 7.12 | Requirement for valves in vent, drain and injection lines | P |
| 7.13 | Wrench head design | P |
| 7.13 | Handwheel diameter(s) | A |
| 7.13 | Number of turns | M |
| 7.14 | Locking devices | P |
| 7.18.1 | Actuator output, if greater than drive train strength | A |
| Clause/subclause | Information | Provider a |
| 7.19 | Lifting points | A |
| 7.19 | Lifting procedure | M |
| 7.20.3 | Demonstration of valve function under pressure and pipe loads and moments | M |
| 7.22 | Requirements for fire-type-testing certification | P |
| 7.22 | Fire type-testing certificate if not in accordance with Clause D.5 | A |
| 7.23 | Anti-static device, if not provided on soft seal valve | A |
| 7.23 | Anti-static device testing per Clause B.5 | P |
| 8.1 | Material specification | A |
| 8.2 | Commissioning fluids | P |
| 8.4 | Composition limits | A |
| 8.4 | Chemical composition of welding end | A |
| 8.4 | Chemical composition of other materials | A |
| 8.5 | Charpy tests for other materials | A |
| 8.6 | Bolting for hydrogen embrittlement | A |
| 8.7 | Sour-service requirements | P |
| 8.7.2 | HIC acceptance criteria | A |
| 9.1 | Additional welding requirements to meet pipeline requirements | P |
| 9.3 | Use of other hardness test methods | A |
| 9.4 | Through-wall weld repairs | A |
| 9.4 | Weld repairs to correct defects in plates and forgings | A |
| 9.4 | Specification for defect removal and repair | M |
| 10.1 | NDE requirements | P |
| 10.4 | NDE before final heat treatment | A |
| 10.4 | NDE requirements for weld repair | P |
| 10.5 | NDE of weld ends | P |
| 11.1 | Supplementary tests in Annex B | P |
| 11.1 | Use of light oil as an alternative to water for test media | A |
| 11.1 | Test sequence | A |
| 11.1 | Use of antifreeze in test water | A |
| 11.3 | Method of closing ends | A |
| 11.4.1 | Lubricant removed for testing | A |
| 11.4.3 | Other leakage rates | A |
| 11.4.4.3 | Valve seat functionality | P |
| 11.4.5 | Cavity relief test | P-M |
| 11.4.7 | Alternative test: high-pressure gas in lieu of water | A |
| 11.5 | Pneumatic testing of drain, vent and sealing lines | A |
| Clause/subclause | Information | Providera |
| 11.5 | Test pressure of sealant injection lines | A |
| 12 | Coating requirements | A |
| 13 | Omission of marking requirements on valves NPS 2 and smaller | A |
| 13 | Marking requirements | P |
| 15 | Requirement for longer data-retention period | P |
| 15 | Requirement for supplementary information | P |
| Annex A | NDE requirements | P |
| Annex B | Supplementary test requirements | P |
| Annex C | Supplementary documentation requirements | P |
| Annex D | Purchasing guidelines | P |
| a M indicates information to be supplied by manufacturer;M-P indicates information to be supplied by manufacturer when required by purchaser;P indicates information to be supplied by purchaser;A indicates information to be established by agreement. | ||
Annex E (informative)
Marking example
To illustrate the requirements for marking specified in this International Standard, a 200 mm carbon steel gate valve, pressure class 600 (PN 100) with ring joint end flanges, a 664 mm face-to-face dimension, a maximum operating pressure rating of 10 MPa (100 bar), 13 % chromium steel trim and manufactured in April 2007 should be marked as follows:
| ABCO | (Item 1: name of manufacturer) |
| PN 100 or 600 | (Item 2: pressure class) |
| WCC | (Item 5: body material) |
| DN 200 or 8 | (Item 6: nominal valve size) NOTE Item 6 can also be marked on nameplate or on both body and nameplate. |
| R49 | (Item 9: ring joint identification on flange edge) |
| 12345 | (Item 13: serial number) |
On the bonnet/cover
| 12345 | (Item 6: bonnet/cover melt identification) |
| ABCO | (Item 1: manufacturer) |
| PN 100 or 600 | (Item 2: pressure class) |
| 10,4 MPa or 104 bar at – 29 °C;1 500 psi at – 20 °F | (Item 3: maximum operating pressure at minimum operating temperature |
| 10,2 MPa or 102 bar at 121 °C;1 478 psi at 250 °F | maximum operating pressure at maximum operating temperature) |
| WCC | (Item 5: body material) |
| Stem CR13Disc CR13Seat CR13orCR13 CR13 CR13orCR13CR13CR13 | (Item 7: trim identification) |
| 664 mm or 26.13 | (Item 4: face-to face/end-to end dimensions; see 7.4) |
F.1 Scope
The API Monogram Program allows an API Licensee to apply the API Monogram to products. The API Monogram Program delivers significant value to the international oil and gas industry by linking the verification of an organization's quality management system with the demonstrated ability to meet specific product specification requirements. The use of the Monogram on products constitutes a representation and warranty by the Licensee to purchasers of the products that, on the date indicated, the products were produced in accordance with a verified quality management system and in accordance with an API product specification. When used in conjunction with the requirements of the API License Agreement, API Specification Q1, in its entirety, defines the requirements for those organizations who wish to voluntarily obtain an API License to provide API monogrammed products in accordance with an API product specification.
API Monogram Program Licenses are issued only after an on-site audit has verified that the Licensee conforms to the requirements described in API Specification Q1 in total, and the requirements of an API product specification. Customers/Users are requested to report to API all problems with API monogrammed products. The effectiveness of the API Monogram Program can be strengthened by Customers/Users reporting problems encountered with API monogrammed products. A nonconformance may be reported using the API Nonconformance Reporting System available at https://ncr.api.org. API solicits information on new product that is found to be nonconforming with API specified requirements, as well as field failures (or malfunctions), which are judged to be caused by either specification deficiencies or nonconformities with API specified requirements. This Annex sets forth the API Monogram Program requirements necessary for a supplier to consistently produce products in accordance with API specified requirements For information on becoming an API Monogram Licensee, please contact API, Certification Programs, 1220 L Street, N. W., Washington, DC 20005 or call 202-962-4791 or by email at certification@api.org.
F.2 References
In addition to the referenced standards listed in Section 3, this Annex references the following standard:
API Specification Q1
For licensees under the Monogram Program, where cited these requirements are mandatory. Referenced standards used by the Manufacturer may be either the applicable revision shown in Section 3 and herein, or the latest revision.
F.3 API Monogram Program: Licensee Responsibilities
F.3.1 For all organizations desiring to acquire and maintain a license to use the API Monogram, conformance with the following shall be required at all times:
a. The quality management system requirements of API Specification Q1,
b. The API Monogram Program requirements of API Specification Q1, Annex A,
c. The requirements contained in the API product specification(s) for which the organization desires to be licensed,
d. The requirements contained in the API Monogram Program License Agreement.
F.3.2 When an API Licensed organization is providing an API monogrammed product, conformance with API specified requirements, described in API Specification Q1, including Annex A, is required.
F.3.3 Each Licensee shall control the application of the API Monogram in accordance with the following:
a. Each Licensee shall develop and maintain an API Monogram Marking Procedure that documents the marking / monogramming requirements specified by the API product specification to be used for application of the API Monogram by the Licensee. The marking procedure shall define the location(s) where the Licensee shall apply the API Monogram and require that the Licensee's license number and date of manufacture be marked on monogrammed products in conjunction with the API Monogram. At a minimum, the date of manufacture shall be two digits representing the month and two digits representing the year (e.g., 05-07 for May 2007) unless otherwise stipulated in the applicable API product specification. Where there are no API product specification marking requirements, the Licensee shall define the location(s) where this information is applied.
b. The API Monogram may be applied at any time appropriate during the production process but shall be removed in accordance with the Licensee's API Monogram Marking Procedure if the product is subsequently found to be nonconforming with API specified requirements. Products that do not conform to API specified requirements shall not bear the API Monogram.
c. Only an API Licensee may apply the API Monogram and its license to API monogrammable products. For certain manufacturing processes or types of products, alternative Monogram marking procedures may be acceptable. The current API requirements for Monogram Marking are detailed in the API Policy Document, Monogram Marking Requirements, available on the API Monogram Program website at http://www.api.org/certifications/monogram/.
d. The API Monogram shall be applied at the licensed facility.
e. The authority responsible for applying and removing the API Monogram shall be defined in the Licensee's API Monogram Marking Procedure.
F.3.4 Records required by API product specifications shall be retained for the period of time specified therein. Records specified to demonstrate achievement of the effective operation of the quality system shall be maintained for a minimum of 5 years.
F.3.5 Any proposed change to the Licensee's quality program to a degree requiring changes to the quality manual shall be submitted to API for acceptance prior to incorporation into the Licensee's quality program.
F.3.6 Licensee shall not use the API Monogram on letterheads or in any advertising (including company-sponsored web sites) without an express statement of fact describing the scope of Licensee's authorization (license number).
F.4 Marking Requirements
These marking requirements apply only to those API licensees wishing to mark their products with the API Monogram.
F.4.1 Manufacturers shall either mark equipment on the nameplate with “API 6D” alone or “API 6D” in addition to the marking requirements of Item 16 in Table 12 of Section 13.
F.4.2 As a minimum, equipment should be marked with English (Imperial) Units.
F.4.3 The API Monogram shall be marked on the nameplate, in addition to the marking requirements of Section 13. For valves smaller than DN 50 (NPS 2), the nameplate shall not be omitted, but may be attached to the valve with stainless steel wire.
F.4.4 The API Monogram License number shall not be used unless it is marked in conjunction with the API Monogram.
F.5 API Monogram Program: API Responsibilities
F.5.1 The API shall maintain records of reported problems encountered with API monogrammed products. Documented cases of nonconformity with API specified requirements may be reason for an audit of the Licensee involved, (also known as Audit for “cause”).
F.5.2 Documented cases of specification deficiencies shall be reported, without reference to Licensees, Customers or Users, to API Subcommittee 18 (Quality) and to the applicable API Standards Subcommittee for corrective actions.
Bibliography
[1] API 6FA, Specification for Fire Test for Valves
[2] API 6FC, Specification for Fire Test for Valve with Automatic Backseats
[3] API 6FD, Specification for Fire Test for Check Valves
[4] API 607, Specification for Testing of Valves — Fire Type-Testing Requirements
[5] API Spec 6D, Pipeline Valves
[6] ISO 14723, Petroleum and natural gas industries — Pipeline transportation systems — Subsea pipeline valves
[7] ISO/TS 29001, Petroleum, petrochemical and natural gas industries — Sector-specific quality management systems — Requirements for product and service supply organizations
[8] ISO 5211, Industrial valves — Part-turn actuator attachments
[9] ISO 13623, Petroleum and natural gas industries — Pipeline transportation systems
[10] MSS SP-25-1998, Standard Marking System for Valves, Fittings, Flanges and Unions
[11] EN 12516-1, Industrial valves — Shell design strength — Part 1: Tabulation method for steel valve shells
[12] EN 13445-3, Unfired pressure vessels — Part 3: Design
[13] ASTM E18, Standard Test Methods for Rockwell Hardness of Metallic Materials
[14] ASTM E92, Standard Test Method for Vickers Hardness of Metallic Materials
[15] ASME B16.25-2003, Buttwelding Ends
Date of Issue: August 2011
Affected Publication: API Specification 6D/ISO 14313, Specification for Pipeline Valves, 23rd Edition, April 2008
ERRATA 6 (Includes Errata 1, Errata 2, Errata 3, Errata 4, and Errata 5)
These errata correct editorial errors in the 23rd Edition of API Spec 6D.
Page 2, Section 3, Normative references, replace:
ASME B16.5-1996, Pipe Flanges and Flanged Fittings : NPS 1/2 through 24 with ASME B16.5, Pipe Flanges and Flanged Fitting: NPS 1/2 through 24
ASME B31.8-2003, Gas Transmission and Distribution Piping Systems with ASME B31.8-2007, Gas Transmission and Distribution Piping Systems
ASME B16.10-2000, Face-to-Face and End-to-End Dimensions of Valves with ASME B16.10, Face-to-Face and End-to-End Dimensions of Valves
ASME B16.34-2004, Valves, Flanged, Threaded, and Welding End with ASME B16.34, Valves, Flanged, Threaded, and Welding End
ASME B16.47-2006, Large Diameter Steel Flanges : NPS 26 Through NPS 60 Metric/Inch Standard
with
ASME B16.47, Large Diameter Steel Flanges : NPS 26 Through NPS 60 Metric/Inch Standard
ASME B31.4-2006, Pipeline Transportation Systems for Liquid Hydrocarbons and Other Liquids with ASME B31.4-2009, Pipeline Transportation Systems for Liquid Hydrocarbons and Other Liquids
ASME B31.8-2007, Gas Transmission and Distribution Piping Systems with ASME B31.8-2010, Gas Transmission and Distribution Piping Systems
Page 3, Section 3, Normative references, replace:
ASME Boiler and Pressure Vessel Code — Section VIII: Rules for Construction of Pressure Vessels Division 2: Alternative Rules
with
ASME Boiler and Pressure Vessel Code — Section VIII: Rules for Construction of Pressure Vessels — Division 2-2004: Alternative Rules
| 150 | 6 | 403 | 457 | 419 | — | — | — |
| 65 | 21/2 | 508 | 508 | 514 |
Page 41, Section 7.7.2, replace:
ASME B31.8-2003
with
ASME B31.8-2007
and
Figures 14 and 15
with
Figures I-4 and I-5 Page 45, Section 7.20.2, second sentence, replace:
ASME Code Section VIII, Division 2, Part AD-132
with
ASME Code Section VIII, Division 2-2004, Part AD-132
Page 49, Section 9.3, Note, delete:
by agreement
Page 49, Section 9.4, second paragraph, second sentence, add: "pipe pups to valve" after "Repairs of fabrication welds" On page 51, withdraw:
Section 10.2.3.2 Gauge range
Renumber:
10.2.3.3 (from Addendum 1) as 10.2.3.2
Page 63, Section B.3.3, replace:
0,55 MPa ± 00,7 MPa
with
0,55 MPa ± 0,07 MPa
On page 64, add to the end of Section B.4.2
"Acceptance criteria shall be per the requirements of 11.4.3"
On page 66, add to the end of Section B.10
"Acceptance criteria shall be per the requirements of 11.4.3"
On page 66, add to the end of Section B.11
"Acceptance criteria shall be per the requirements of 11.4.3"
On page 66, add to the end of Section B.12
"Acceptance criteria shall be per the requirements of 11.4.3"
Page 71, Table D.1, beginning of last box, replace:
Other requirements
with
Other requirements
Page 71, Table D.1, after "ISO 15156 (all parts)? Yes ____ No ____ " add the following line:
If yes, specify % mass fraction of H2S ____; pH ____; % mass fraction of chlorides ____; temperature ____
Annex G
(normative)
API Regional Annex
Page 1, Section 2, add the following text:
2.4 Processes requiring validation
The following operations performed during manufacturing shall be validated as the resulting output cannot be verified by subsequent monitoring or measurement. The following processes shall be validated, by the manufacturer, in accordance with their quality system:
— Nondestructive Examination (NDE)—reference 10.1;
— Welding—reference Section 9.0;
— Heat Treating—reference 8.1;
— Plating/coating that may impact product performance, by agreement.
Page 3, Section 3, add the following reference:
EN 473, Nondestructive testing—Qualification and certification of NDT personnel—General principles Page 44, Section 7.20.1, replace with the following text:
The design thrust or torque for all drive train calculations shall be at least two times the breakaway thrust or torque, unless otherwise agreed.
Page 48, Section 8, add the following text:
8.9 Heat-treating equipment qualification
All heat treating of parts and test coupons shall be performed with “production type” equipment meeting the requirements specified by the manufacturer. A recommended
practice for heat-treating furnace calibration can be found in Annex H of this international standard.
"Production type" heat-treating equipment shall be considered equipment that is routinely used to process production parts.
Page 51, Section 10.2.1, replace with the following text:
Equipment used to inspect, test, or examine material or other equipment used for acceptance shall be identified, controlled, calibrated and adjusted at specified intervals in accordance with documented manufacturer instructions, and consistent with nationally or internationally recognized standards specified by the manufacturer, to maintain the accuracy required by this international standard.
Page 51, Section 10.2.3.1, replace with the following text:
Test pressure-measuring devices shall be accurate to at least ± 2,0 % of full scale. If pressure gauges are used in lieu of pressure transducers; they shall be selected such that the test pressure is indicated within 20 % and 80 % of the full-scale value. Pressure recording devices are outside the scope of 10.2.3.1 unless used for both measurement and recording.
Page 51, Section 10.2.3.3, replace with the following text:
Pressure-measuring devices shall be periodically calibrated with a master pressure-measuring device or dead-weight tester to at least three equidistant points of full scale (excluding zero and full scale as required points of calibration).
Page 51, add the following to Section 10.2.3:
10.2.3.4 Calibration intervals
Calibration intervals shall be established for calibrations based on repeatability and degree of usage. Intervals may be lengthened and shall be shortened based on recorded calibration history. Calibration intervals shall be a maximum of three months until recorded calibration history can be established by the manufacturer and new longer intervals (three months maximum increment) established.
Page 51, Section 10.3, replace with the following text:
10.3 Qualification of personnel
10.3.1 Nondestructive examination (NDE) personnel
NDE personnel shall be qualified in accordance with the manufacturer's documented training program which is based on the requirements specified in ISO 9712, EN 473 or ASNT SNT-TC-1A.
10.3.2 Visual examination personnel
Personnel performing visual inspection for acceptance shall take and pass an annual vision examination in accordance with the manufacturer's documented procedures which meet the applicable requirements of ISO 9712, EN 473, or ASNT SNT-TC-1A.
10.3.3 Other personnel
All personnel performing other quality control activities directly affecting material and product quality shall be qualified in accordance with manufacturer's documented requirements.
10.3.4 Welding inspectors
Personnel performing visual inspections of welding operations and completed welds shall be qualified and certified as:
— AWS certified welding inspector,
— AWS senior certified welding inspector,
— AWS certified associate welding inspector, or
— welding inspector certified by the manufacturer's documented training program.
Page 79, add the following reference to the Bibliography:
[16] SAE AMS-H-6875G
H.1 General
All heat treatment of parts and test coupons shall be performed with equipment meeting the requirements of this annex.
H.2 Temperature tolerance
The temperature at any point in the working zone shall not vary by more than ± 13 °C (± 25 °F) from the furnace set-point temperature after the furnace working zone has been brought up to temperature. Furnaces which are used for tempering, ageing and/or stress-relieving shall not vary by more than ± 8 °C (± 15 °F) from the furnace set-point temperature after the furnace working zone has been brought up to temperature.
H.3 Furnace calibration
H.3.1 General
Heat treatment of production parts shall be performed with heat-treating equipment that has been calibrated and surveyed.
H.3.2 Records
Records of furnace calibration and surveys shall be maintained for a period not less than two years.
H.3.3 Temperature survey method for calibration of batch-type furnaces
A temperature survey within the furnace working zone(s) shall be performed on each furnace at the maximum and minimum temperatures for which each furnace is to be used. A minimum of nine thermocouple test locations shall be used for all furnaces having a working zone greater than 0,3 m3 ( 10 ft3 ).
For each 3,5 m
3 (125 ft
3
) of furnace working zone surveyed, at least one thermocouple test location shall be used, up to a maximum of 40 thermocouples. See Figure H.1 and Figure H.2 for examples of thermocouple locations. For furnaces having a working zone less than 0,3 m3 ( 10 ft3 ), the temperature survey may be made with a minimum of three thermocouples located either at the front, centre and rear, or at the top, centre and bottom of the furnace working zone.
After insertion of the temperature-sensing devices, readings shall be taken at least once every 3 min to determine when the temperature of the furnace working zone approaches the bottom of the temperature range being surveyed. Once the furnace temperature has reached the set-point temperature, the temperature of all test locations shall be recorded at 2-min intervals, maximum, for at least 10 min. Then readings shall be taken at 5-min intervals, maximum, for sufficient time (at least 30 min) to determine the recurrent temperature pattern of the furnace working zone.
Before the furnace set-point temperature is reached, none of the temperature readings shall exceed the set-point temperature by more than 13 °C (25 °F). After the furnace control set-point temperature is reached, no temperature reading shall vary beyond the limits specified. The temperatures within each furnace shall be surveyed within one year prior to use of the furnace for heat treatment.
When a furnace is repaired or rebuilt, a new temperature survey shall be carried out before the furnace is used for heat treatment.




H.3.4 Continuous-type furnaces method
Furnaces used for continuous heat treatment shall be calibrated in accordance with procedures specified in SAE AMS-H-6875G.
H.4 Instruments
H.4.1 General
Automatic controlling and recording instruments shall be used.
Thermocouples shall be located in the furnace working zone(s) and protected from furnace atmospheres by means of suitable protective devices.
H.4.2 Accuracy
The controlling and recording instruments used for the heat-treatment processes shall be accurate to ± 1 % of their full-scale range.
H.4.3 Calibration
Temperature-controlling and -recording instruments shall be calibrated at least once every three months.
Equipment used to calibrate the production equipment shall be accurate to ± 0,25 % of full-scale range.
Date of Addendum Issue: August 2011
Effective Addendum Date: February 1, 2012
Affected Publication: API Specification 6D, Specification for Pipeline Valves, 23rd Edition, April 2009, Effective Date: October 1, 2008
ADDENDUM 2
Insert Annex I and Annex J at the end of the document.
I.1 General
This annex provides a recommended practice pertaining to valves used in jurisdictional pipeline systems. Valves used in transportation of natural and other gas and hazardous liquids or carbon dioxide by pipeline are usually regulated by the national governments of the countries in which the pipeline is located. This annex specifies the requirements for extended hydrostatic shell testing that shall be performed by the manufacturer if specified by the purchaser. This annex also specifies the test records to be provided to the purchaser and record retention requirements.
I.2 Hydrostatic shell testing requirements:
The hydrostatic shell test shall be in accordance with 11.1 and 11.3 of this specification with a test duration of at least four (4) hours, unless otherwise agreed.
I.2.1 Test record requirements:
Test records shall contain the following as a minimum and be provided to the purchaser.
I.2.1.1 The name of the manufacturer, name of the organization that performs testing (if other than the valve manufacturer), the identification of the individual responsible for performing the test, date, time and location of test.
I.2.1.2 Serial number, size, class and end connection.
I.2.1.3 Test medium (fluid) used.
I.2.1.4 The beginning, ending, and actual test pressure and temperature readings, unless otherwise agreed.
I.2.1.5 The test duration.
I.2.1.6 A chart recording or digital record of the pressure showing the raise from zero to pressure at the beginning of the test and return to zero at the end.
I.2.1.7 Any significant variations in pressure or temperature for the particular test.
I.2.1.8 Any leaks or failures and their disposition.
I.2.1.9 Certificates of calibration for all instrumentations used in the test, such as pressure transducers, pressure gauges, temperature devices and chart recorders.
I.2.2 Minimum requirements for pressure transducers, pressure gauges, temperature devices and chart recorders
I.2.2.1 Pressure transducers, pressure gauges, temperature devices and chart recorders shall be calibrated in accordance with section 10 of this specification, but at an interval not greater than 12 months.
I.2.3 Record retention requirement:
I.2.3.1 Test records in I.2.1 shall be shall be provided to the purchaser and maintained by the manufacturer in accordance with section15 of this specification, unless otherwise agreed.
J.0 General
This annex specifies quality levels for pipeline valves. QSL 1 is the quality level as specified in API 6D. QSL 2 to 4 are quality levels are optional and may be specified by the purchaser. The QSLs increase in stringency of requirements with the QSL number. The QSLs include specific requirements for non-destructive examination (NDE), pressure testing, and documentation of the manufacturing process.
J.1 Specification of quality levels for NDE
Table J.1 specifies the additional NDE requirements by inspection code for QSL 3 and QSL 4. These requirements vary by the type of raw material for the item being inspected. There are no additional NDE requirements for QSL 1 and 2. Table J.2 specifies the extent, method, and acceptance criteria for the various inspection codes used in Table J.1.
| Part | QSL 3 | QSL 4 | ||||
| Cast | Forged | Plate | Cast | Forged | Plate | |
| Body or Closures and end connections or Bonnet or cover or Gland housing | VT1 and RT1a | VT2 | VT2 and UT2 | VT1 and RT1a,f and UT1 g and MT1 or PT1 | VT2 and UT2 and MT1 or PT1 | VT2 and UT2 and MT1 or PT1 |
| Welding endsb | VT1 and RT3 or UT4 and MT1 or PT1 | VT2 and UT2 and MT1 or PT1 | VT2 and UT2 and MT1 or PT1 | VT1 and RT3 or UT4 and MT1 or PT1 | VT2 and UT2 and MT1 or PT1 | VT2 and UT2 and MT1 or PT1 |
| Stem or shaftc, g | N/A | VT2 and MT1 or PT1 | N/A | N/A | VT2 and UT2 and MT1 or PT1 | N/A |
| Trunniond, gOrTrunnion/bearing plates | VT1 | VT2 | VT2 | VT1 and UT1 and MT1 or PT1 | VT2 and MT1 or PT1 | VT2 and UT2 and MT1 or PT1 |
| Bolting-pressure containing | N/A | VT2 | N/A | N/A | VT2 and MT1 or PT1 | N/A |
| Ball or gatec | VT1 | VT2 | VT2 | VT1 and MT1 or PT1 | VT2 and MT1 or PT1 | VT2 and MT1 or PT1 |
| Plug or clapper discc, g | VT1 | VT2 | VT2 | VT1 and RT3 or UT4 and MT1 or PT1 | VT2 and MT1 or PT1 | VT2 and MT1 or PT1 |
| Clapper disc arm | VT1 | VT2 | VT2 | VT1 and UT4 and MT1 or PT1 | VT2 and MT1 or PT1 | VT2 and MT1 or PT1 and UT2 |
| Seat ringsc, g | VT1 | VT2 | VT2 | VT1 and MT1 or PT1 | VT2 and MT1 or PT1 | VT2 and MT1 or PT1 |
| Corrosion –resistant overlay | VT4 and PT1 | VT4 and UT3 and PT1 | ||||
| Part | QSL 3 | QSL 4 | ||||
| Cast | Forged | Plate | Cast | Forged | Plate | |
| Seals Gaskets | VT4 | |||||
| Seat springs | VT4 | |||||
| Pressure-containing welds | VT3 and RT2 and MT1 or PT1 or VT3 and UT3 and MT1 or PT1 | |||||
| Reinforcement and stiffening welds | VT4 | |||||
| Fillet and attachment welds to pressure-containing parts | VT3 and MT1 or PT1 | |||||
| Pipe pup to valve welds or Pipe pups e | VT3 and RT2 and MT1 or PT1 | |||||
| Plating | VT4 | |||||
| Hardfacing | VT4 and PT1 | |||||
| Sealing surfaces | MT2 or PT2 | |||||
| NOTE 1 See Table J.2 for specification of the examinations referred to in this table. NOTE 2 N/A means that the manufacturer is not allowed to use this material form for that specific part NOTE 3 All the NDE activities listed above for a specific product form or forms shall be conducted. | ||||||
| a RT1 may be replaced by UT4 by agreement. b NDE back 50 mm from weld end. c MT/PT to be performed prior to coating, plating or overlay. d Trunnion may be pressure-containing or pressure-controlling, depending on design type. If the trunnion is a pressure-containing part then the requirements for body apply. e NDE requirements of pipe pups shall be established by agreement. f RT1 plus UT1 may be replaced by RT3. g Requirements for examination of bar material shall be as for forgings | ||||||
| Examination | NDE | Extent | Method | Acceptance |
| RT1 | RT casting | Critical areas per ASME B16.34 | ASME Section V, Article 2 | ASME Section VIII Div.1, Appendix 7 |
| RT2 | RT weldments | 100 % where practicable | ASME Section V, Article 2 | ASME Section VIII Div. 1, UW51 (linear indications); ASME Section VIII Div.1, Appendix 4 (round indications) |
| RT3 | RT casting | 100 % | ASME Section V, Article 2 | ASME Section VIII Div. 1, Appendix 7 |
| UT1 | UT casting | Remaining areas not covered by RT1 | ASME Section V, Article 5 (direct and shear wave) | ASTM A 609/A 609M, Table 2, Quality Level 2 |
| UT2 | UT forging and plate | All surfaces | ASME Section V, Article 5 | Forgings : ASME Section VIII Div. 1-UF 55 for angle bean and ASME B16.34 for straight beam. Plate: ASTM A578/A578M Acceptance standard level B |
| UT3 | UT weldments | 100 % where weld joint geometry allows acceptable test results | ASME Section V, Article 4 (direct and shear wave); Article 23 | ASME Section VIII Div. 1, Appendix 12 |
| UT overlay | 100 % where part geometry allows acceptable test results | ASTM A578/A 578M Acceptance standard level C | ||
| UT4 | casting | 100 % | ASME Section V, Article 5 | ASTM A 609/A 609M, Table 2, Quality Level 1 |
| MT1 | MT | 100 % accessible surfaces | ASME Section V, Article 7 | ASME Section VIII Div.1, Appendix 6 |
| MT2 | MT | 100 % sealing surfaces | ASME Section V, Article 7 | No rounded or linear indications |
| PT1 | PT | 100 % accessible surfaces | ASME Section V, Article 6 | ASME Section VIII Div. 1, Appendix 8 |
| PT2 | PT | 100 % sealing surfaces | ASME Section V, Article 6 | No rounded or linear indications |
| VT1 | VT casting | 100% accessible surfaces | MSS SP-55 | Type 1 none acceptable; Type 2 to 12 – A and B |
| VT2 | VT forging and plate | 100% accessible surfaces | As required by ASTM product specification | As required by ASTM product specification |
| VT3 | VT weldments | 100% accessible surfaces | ASME Section V, Article 9 | Undercut shall not reduce the thickness in the area (considering both sides) to below the minimum thickness. Surface porosity and exposed slag are not permitted on or within 45 mm of seating surfaces. |
| VT4 | VT weldments and others | All accessible surfaces | ASME Section V, Article 9 | No visible defects |
J.2 Hydrostatic/Pneumatic testing
Table J.3 defines the additional test requirements for QSL2, QSL 3 and QSL 4. All QSL 4 pressure tests shall be recorded on time-based equipment. There are no additional testing requirements for QSL 1.
J.3 Documentation
Table J.4 specifies the final assembly documentation requirements for QSL2, QSL3, and QSL 4. There are no additional documentation requirements for QSL 1.
| Required documentation to be sent with the valve(-s) | QSL 2 | QSL 3 | QSL 4 |
| Certificate of conformance to this specification and QSL | X | X | X |
| Hardness test report on pressure-controlling parts | X | ||
| Hardness test report on pressure-containing parts | X | X | |
| Pressure test report, (including pressure, test duration, test medium, and acceptance criteria) including copy of chart recorder used on pressure test | X | X | X |
| Calibration certificates on pressure test equipment used (e.g. pressure gauges, transducers and chart recorders) | X | ||
| Heat treatment records including times and temperatures, e.g. charts | X | ||
| Material test reports on all pressure containing and pressure controlling parts. | X | X | X |
| For sour service valves, certificate of conformance to ANSI/NACE MR0175/ISO 15156 | X | X | X |
| General arrangements drawings; | X | ||
| NDE records | X | X | |
| Cross-sectional assembly drawings with parts list and materials list; | X | X | |
| Installation, operation and maintenance instructions/manuals | X | X |
Publications
Order Form
The member discount does not apply to purchases made for the purpose of resale or for incorporation into commercial products, training courses, workshops, or other commercial enterprises.
| Available through IHS: | ||
| Phone Orders: | 1-800-854-7179 | (Toll-free in the U.S. and Canada) |
| 303-397-7956 | (Local and International) | |
| Fax Orders: | 303-397-2740 | |
| Online Orders: | global.ihs.com | |
| Date: | □API Member (Check if Yes) | ||
| Invoice To (□ Check here if same as “Ship To”) | Ship To (UPS will not deliver to a P.O. Box) | ||
| Name: | Name: | ||
| Title: Spec 6DSS, Specification on Subsea Pipeline Valves | Title: Spec 6A, Specification for Wellhead and Christmas Tree Equipment | ||
| Company: | Company: | ||
| Department: | Department: | ||
| Address: | Address: | ||
| City: | State/Province: | City: | State/Province: |
| Zip/Postal Code: | Country: | Zip/Postal Code: | Country: |
| Telephone: | Telephone: | ||
| Fax: | Fax: | ||
| Email: | Email: | ||
| Quantity | Title | SO★ | Unit Price | Total |
| Spec 6DSS, Specification on Subsea Pipeline Valves | $137.00 | |||
| Spec 6A, Specification for Wellhead and Christmas Tree Equipment | $244.00 | |||
| Spec 6FA, Specification for Fire Test for Valves | $91.00 | |||
| Spec 6FD, Specification for Fire Test for Check Valves | $83.00 | |||
| Spec 14A, Specification for Subsurface Safety Valve Equipment | $161.00 | |||
| Subtotal | ||||
| Total (in U.S. Dollars) | ||||
| ★ To be placed on Standing Order for future editions of this publication, place a check mark in the SO column and sign here: | ||||
| Pricing and availability subject to change without notice. | ||||
API provides additional resources and programs to the oil and natural gas industry which are based on API Standards. For more information, contact:
API MONOGRAM® LICENSING PROGRAM
Phone: 202-962-4791
Fax: 202-682-8070
Email: certification@api.org
API QUALITY REGISTRAR (APIQR®)
> ISO 9001 Registration
> ISO/TS 29001 Registration
> ISO 14001 Registration
> API Spec Q1® Registration
Phone: 202-962-4791
Fax: 202-682-8070
Email: certification@api.org
API PERFORATOR DESIGN REGISTRATION PROGRAM
Phone: 202-682-8490
Fax: 202-682-8070
Email: perfdesign@api.org
API TRAINING PROVIDER CERTIFICATION PROGRAM (API TPCP™)
Phone: 202-682-8490
Fax: 202-682-8070
Email: tpcp@api.org
API INDIVIDUAL CERTIFICATION PROGRAMS (ICP®)